These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 10458285)

  • 1. Reinforcement of osteosynthesis screws with brushite cement.
    Van Landuyt P; Peter B; Beluze L; Lemaître J
    Bone; 1999 Aug; 25(2 Suppl):95S-98S. PubMed ID: 10458285
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of cement compressive strength and porosity on augmentation performance in a model of orthopedic screw pull-out.
    Pujari-Palmer M; Robo C; Persson C; Procter P; Engqvist H
    J Mech Behav Biomed Mater; 2018 Jan; 77():624-633. PubMed ID: 29100205
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method.
    Renner SM; Lim TH; Kim WJ; Katolik L; An HS; Andersson GB
    Spine (Phila Pa 1976); 2004 Jun; 29(11):E212-6. PubMed ID: 15167670
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hip screw augmentation with an in situ-setting calcium phosphate cement: an in vitro biomechanical analysis.
    Moore DC; Frankenburg EP; Goulet JA; Goldstein SA
    J Orthop Trauma; 1997 Nov; 11(8):577-83. PubMed ID: 9415864
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Restoration of pedicle screw fixation with an in situ setting calcium phosphate cement.
    Moore DC; Maitra RS; Farjo LA; Graziano GP; Goldstein SA
    Spine (Phila Pa 1976); 1997 Aug; 22(15):1696-705. PubMed ID: 9259778
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices.
    Eriksson F; Mattsson P; Larsson S
    J Orthop Trauma; 2002 May; 16(5):302-10. PubMed ID: 11972072
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cement-augmented screw fixation for calcaneal fracture treatment: a biomechanical study comparing two injectable bone substitutes.
    Fuchs KF; Heilig P; McDonogh M; Boelch S; Gbureck U; Meffert RH; Hoelscher-Doht S; Jordan MC
    J Orthop Surg Res; 2020 Nov; 15(1):533. PubMed ID: 33189144
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical evaluation of fracture fixation augmented with tricalcium phosphate bone cement in a porous osteoporotic cancellous bone model.
    Collinge C; Merk B; Lautenschlager EP
    J Orthop Trauma; 2007 Feb; 21(2):124-8. PubMed ID: 17304068
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation.
    Stadelmann VA; Bretton E; Terrier A; Procter P; Pioletti DP
    J Biomech; 2010 Nov; 43(15):2869-74. PubMed ID: 20728888
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction.
    Choma TJ; Pfeiffer FM; Swope RW; Hirner JP
    Spine (Phila Pa 1976); 2012 Dec; 37(26):E1628-32. PubMed ID: 22996264
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of an osteoconductive resorbable calcium phosphate cement and polymethylmethacrylate for augmentation of orthopedic screws in the pelvis of canine cadavers.
    Hutchinson GS; Griffon DJ; Siegel AM; Pijanowski GJ; Kurath P; Eurell JA; Johnson AL
    Am J Vet Res; 2005 Nov; 66(11):1954-60. PubMed ID: 16334956
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of a new composite PMMA-HA/Brushite bone cement for spinal augmentation.
    Aghyarian S; Rodriguez LC; Chari J; Bentley E; Kosmopoulos V; Lieberman IH; Rodrigues DC
    J Biomater Appl; 2014 Nov; 29(5):688-98. PubMed ID: 25085810
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation of pull-out strength of cement-augmented pedicle screws with CT-volumetric measurement of cement.
    Fölsch C; Goost H; Figiel J; Paletta JR; Schultz W; Lakemeier S
    Biomed Tech (Berl); 2012 Dec; 57(6):473-80. PubMed ID: 23152399
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Enhanced bone screw fixation with biodegradable bone cement in osteoporotic bone model.
    Juvonen T; Koistinen A; Kröger H; Lappalainen R
    J Appl Biomater Funct Mater; 2012 Sep; 10(2):113-8. PubMed ID: 22798235
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Enhancing pedicle screw fixation in the aging spine with a novel bioactive bone cement: an in vitro biomechanical study.
    Zhu Q; Kingwell S; Li Z; Pan H; Lu WW; Oxland TR
    Spine (Phila Pa 1976); 2012 Aug; 37(17):E1030-7. PubMed ID: 22531472
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enhanced mechanical properties of a novel, injectable, fiber-reinforced brushite cement.
    Maenz S; Kunisch E; Mühlstädt M; Böhm A; Kopsch V; Bossert J; Kinne RW; Jandt KD
    J Mech Behav Biomed Mater; 2014 Nov; 39():328-38. PubMed ID: 25171749
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of the degree of osteoporosis on the biomechanical anchoring strength of the sacral pedicle screws: an in vitro comparison between unaugmented bicortical screws and polymethylmethacrylate augmented unicortical screws.
    Zhuang XM; Yu BS; Zheng ZM; Zhang JF; Lu WW
    Spine (Phila Pa 1976); 2010 Sep; 35(19):E925-31. PubMed ID: 20098349
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of two types of resorbable augmentation materials - a cement and an adhesive - on the screw pullout pullout resistance in human trabecular bone.
    Wu D; Pujari-Palmer M; Bojan A; Palmquist A; Procter P; Öhman-Mägi C; Ferguson SJ; Isaksson P; Persson C
    J Mech Behav Biomed Mater; 2020 Oct; 110():103897. PubMed ID: 32957202
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calcium phosphate cement promotes the stability of osteoporotic lumbar pedicle screw by enhancer-injecters with different number of holes.
    Fu S; Zhang Y; Wang R; Zou X; Ai F; Wang J; Ma X; Xia H; Lei W
    BMC Surg; 2023 Nov; 23(1):354. PubMed ID: 37980464
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical analysis of different types of pedicle screw augmentation: a cadaveric and synthetic bone sample study of instrumented vertebral specimens.
    Chao KH; Lai YS; Chen WC; Chang CM; McClean CJ; Fan CY; Chang CH; Lin LC; Cheng CK
    Med Eng Phys; 2013 Oct; 35(10):1506-12. PubMed ID: 23669371
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.