These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 10461301)

  • 1. The effect of biphasic defibrillation on the immediate pacing threshold of a dedicated bipolar, steroid-eluting lead.
    Welch PJ; Joglar JA; Hamdan MH; Nelson L; Page RL
    Pacing Clin Electrophysiol; 1999 Aug; 22(8):1229-33. PubMed ID: 10461301
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prospective evaluation of the effect of biphasic waveform defibrillation on ventricular pacing thresholds.
    Kudenchuk PJ; Poole JE; Dolack GL; Gleva MJ; Anderson J; Troutman C; Bardy GH
    J Cardiovasc Electrophysiol; 1997 May; 8(5):485-95. PubMed ID: 9160224
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Reproducibility of the effectiveness of defibrillation for terminating induced ventricular fibrillation using intraoperatively measured defibrillation threshold energy in patients with implanted cardioverter-defibrillator].
    Jung J; Neuzner J; Himmrich E; Vester E; Michel U; Fries R; Pitschner H; Liebrich A; Ganschow U; Heisel A
    Z Kardiol; 1998 Dec; 87(12):971-7. PubMed ID: 10025070
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pacing following shocks stronger than the defibrillation threshold: impact on defibrillation outcome.
    Chattipakorn N; Fotuhi PC; Ideker RE
    J Cardiovasc Electrophysiol; 2000 Sep; 11(9):1022-8. PubMed ID: 11021473
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Recording of pacing stimulus artifacts by endovascular defibrillation lead systems: comparison of true and integrated bipolar circuits.
    Menz V; Schwartzman D; Drachman D; Michele JJ; Dillon SM
    J Interv Card Electrophysiol; 1998 Sep; 2(3):269-72. PubMed ID: 9870021
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of first-phase polarity of biphasic shocks on defibrillation threshold with a single transvenous lead system.
    Strickberger SA; Man KC; Daoud E; Neary MP; Horwood LE; Niebauer M; Hummel JD; Morady F
    J Am Coll Cardiol; 1995 Jun; 25(7):1605-8. PubMed ID: 7759712
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of failed defibrillation shocks on electrogram amplitude in a nonintegrated transvenous defibrillation lead system.
    Brady PA; Friedman PA; Stanton MS
    Am J Cardiol; 1995 Sep; 76(8):580-4. PubMed ID: 7677081
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of defibrillation efficacy using implantable cardioverter-defibrillator with single- or dual-coil defibrillation leads and active can.
    Lubiński A; Lewicka-Nowak E; Zienciuk A; Królak T; Kempa M; Pazdyga A; Raczak G; Swiatecka G
    Kardiol Pol; 2005 Sep; 63(3):234-41; discussion 242-3. PubMed ID: 16180177
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of bipolar and integrated sensing for redetection of ventricular fibrillation.
    Cooklin M; Tummala RV; Peters RW; Shorofsky SR; Gold MR
    Am Heart J; 1999 Jul; 138(1 Pt 1):133-6. PubMed ID: 10385776
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of pinacidil on postshock activation and ventricular defibrillation threshold in canine hearts.
    Jin Q; Zhang N; Zhou J; Lin CJ; Pang Y; Gu G; Shen WF; Wu LQ
    Acta Pharmacol Sin; 2012 Dec; 33(12):1488-94. PubMed ID: 23064720
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ventricular pacing threshold and time to capture postdefibrillation in patients undergoing implantable cardioverter-defibrillator implantation.
    Khastgir T; Lattuca J; Aarons D; Murphy J; O'Mara V; Juanteguy J; Veltri EP
    Pacing Clin Electrophysiol; 1991 May; 14(5 Pt 1):768-72. PubMed ID: 1712951
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Post-shock synchronized pacing in isolated rabbit left ventricle: evaluation of a novel defibrillation strategy.
    Tang L; Hwang GS; Song J; Chen PS; Lin SF
    J Cardiovasc Electrophysiol; 2007 Jul; 18(7):740-9. PubMed ID: 17388914
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimal method to achieve consistently low defibrillation energy requirements.
    Winter J; Zimmermann N; Lidolt H; Dees H; Perings C; Vester EG; Poll L; Schipke JD; Contzen K; Gams E
    Am J Cardiol; 2000 Nov; 86(9A):71K-75K. PubMed ID: 11084103
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Five-year follow-up of a bipolar steroid-eluting ventricular pacing lead.
    Schwaab B; Fröhlig G; Berg M; Schwerdt H; Schieffer H
    Pacing Clin Electrophysiol; 1999 Aug; 22(8):1226-8. PubMed ID: 10461300
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combined third-generation implantable cardioverter defibrillator with permanent unipolar pacemakers: preliminary observations.
    Haffajee C; Casavant D; Desai P; Moon R; Voukydis P; Pacetti P
    Pacing Clin Electrophysiol; 1996 Feb; 19(2):136-42. PubMed ID: 8834682
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of shock polarity on ventricular defibrillation threshold using a transvenous lead system.
    Strickberger SA; Hummel JD; Horwood LE; Jentzer J; Daoud E; Niebauer M; Bakr O; Man KC; Williamson BD; Kou W
    J Am Coll Cardiol; 1994 Oct; 24(4):1069-72. PubMed ID: 7930199
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Changes in the amplitude of endocardial electrograms following defibrillator discharge: comparison of two lead systems.
    Jung W; Manz M; Moosdorf R; Tebbenjohanns J; Pfeiffer D; Lüderitz B
    Pacing Clin Electrophysiol; 1995 Dec; 18(12 Pt 1):2163-72. PubMed ID: 8771129
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ventricular pacing threshold and refractoriness after defibrillation shocks in patients with implantable cardioverter-defibrillators.
    Yu JC; Lauer MR; Young C; Liem B; Peterson J; Ottoboni L; Sung RJ
    Am Heart J; 1996 Jun; 131(6):1121-6. PubMed ID: 8644590
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: results of the prospective, randomized, multicenter Low-Energy Endotak Trial.
    Neuzner J; Liebrich A; Jung J; Himmrich E; Pitschner HF; Winter J; Vester EG; Michel U; Nisam S; Heisel A
    Am J Cardiol; 1999 Mar; 83(5B):34D-39D. PubMed ID: 10089837
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator. Active Can Investigators.
    Bardy GH; Yee R; Jung W
    J Am Coll Cardiol; 1996 Aug; 28(2):400-10. PubMed ID: 8800117
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.