These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
84 related articles for article (PubMed ID: 10467294)
21. Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart. Larsson HB; Rosenbaum S; Fritz-Hansen T Magn Reson Med; 2001 Aug; 46(2):272-81. PubMed ID: 11477630 [TBL] [Abstract][Full Text] [Related]
22. Tissue ACE inhibition improves microcirculation in remote myocardium after coronary stenosis: MR imaging study in rats. Hiller KH; Ruile P; Kraus G; Bauer WR; Waller C Microvasc Res; 2010 Dec; 80(3):484-90. PubMed ID: 20570682 [TBL] [Abstract][Full Text] [Related]
23. Myocardial perfusion reserve in cardiovascular magnetic resonance: Correlation to coronary microvascular dysfunction. Wöhrle J; Nusser T; Merkle N; Kestler HA; Grebe OC; Marx N; Höher M; Kochs M; Hombach V J Cardiovasc Magn Reson; 2006; 8(6):781-7. PubMed ID: 17060099 [TBL] [Abstract][Full Text] [Related]
24. Equilibrium signal intensity mapping, an MRI method for fast mapping of longitudinal relaxation rates and for image enhancement. Surányi P; Kiss P; Ruzsics B; Brott BC; Simor T; Elgavish GA Magn Reson Imaging; 2007 Jun; 25(5):641-51. PubMed ID: 17540275 [TBL] [Abstract][Full Text] [Related]
25. In vivo study of microcirculation in canine myocardium using the IVIM method. Callot V; Bennett E; Decking UK; Balaban RS; Wen H Magn Reson Med; 2003 Sep; 50(3):531-40. PubMed ID: 12939761 [TBL] [Abstract][Full Text] [Related]
26. Automatic motion correction for quantification of myocardial perfusion with dynamic magnetic resonance imaging. Kawakami K; Murase K; Kumashiro M; Kawakami A; Tanki N; Yamazaki Y; Tabuchi T; Nagayama M; Watanabe Y Magn Reson Med Sci; 2004 Dec; 3(3):105-17. PubMed ID: 16093627 [TBL] [Abstract][Full Text] [Related]
27. The effect of perfusion on T1 after slice-selective spin inversion in the isolated cardioplegic rat heart: measurement of a lower bound of intracapillary-extravascular water proton exchange rate. Bauer WR; Roder F; Hiller KH; Han H; Fröhlich S; Rommel E; Haase A; Ertl G Magn Reson Med; 1997 Dec; 38(6):917-23. PubMed ID: 9402192 [TBL] [Abstract][Full Text] [Related]
28. Quantitative magnetic resonance imaging of capillary water permeability and regional blood volume with an intravascular MR contrast agent. Schwarzbauer C; Morrissey SP; Deichmann R; Hillenbrand C; Syha J; Adolf H; Nöth U; Haase A Magn Reson Med; 1997 May; 37(5):769-77. PubMed ID: 9126952 [TBL] [Abstract][Full Text] [Related]
29. Quantification of pulmonary blood flow and volume in healthy volunteers by dynamic contrast-enhanced magnetic resonance imaging using a parallel imaging technique. Nikolaou K; Schoenberg SO; Brix G; Goldman JP; Attenberger U; Kuehn B; Dietrich O; Reiser MF Invest Radiol; 2004 Sep; 39(9):537-45. PubMed ID: 15308936 [TBL] [Abstract][Full Text] [Related]
30. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI. Natsume T; Ishida M; Kitagawa K; Nagata M; Sakuma H; Ichihara T Magn Reson Imaging; 2015 Nov; 33(9):1059-1065. PubMed ID: 26117690 [TBL] [Abstract][Full Text] [Related]
32. [High-resolution MRI for the quantitative evaluation of subendocardial and subepicardial perfusion under pharmacological stress and at rest]. Ritter CO; del Savio K; Brackertz A; Beer M; Hahn D; Köstler H Rofo; 2007 Sep; 179(9):945-52. PubMed ID: 17705117 [TBL] [Abstract][Full Text] [Related]
33. Combined high-speed NMR imaging of perfusion and microscopic coronary conductance vessels in the isolated rat heart. Hiller KH; Waller C; Voll S; Haase A; Ertl G; Bauer WR Microvasc Res; 2001 Nov; 62(3):327-34. PubMed ID: 11678635 [TBL] [Abstract][Full Text] [Related]
34. MRI quantitative myocardial perfusion with compartmental analysis: a rest and stress study. Vallée JP; Sostman HD; MacFall JR; Wheeler T; Hedlund LW; Spritzer CE; Coleman RE Magn Reson Med; 1997 Dec; 38(6):981-9. PubMed ID: 9402200 [TBL] [Abstract][Full Text] [Related]
35. Rat model of reperfused partial liver infarction: characterization with multiparametric magnetic resonance imaging, microangiography, and histomorphology. Wu X; Wang H; Chen F; Jin L; Li J; Feng Y; DeKeyzer F; Yu J; Marchal G; Ni Y Acta Radiol; 2009 Apr; 50(3):276-87. PubMed ID: 19160078 [TBL] [Abstract][Full Text] [Related]
36. T1 measurement using a short acquisition period for quantitative cardiac applications. Higgins DM; Ridgway JP; Radjenovic A; Sivananthan UM; Smith MA Med Phys; 2005 Jun; 32(6):1738-46. PubMed ID: 16013731 [TBL] [Abstract][Full Text] [Related]
37. Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice. Schwarzbauer C; Morrissey SP; Haase A Magn Reson Med; 1996 Apr; 35(4):540-6. PubMed ID: 8992204 [TBL] [Abstract][Full Text] [Related]
38. Determination of regional blood volume and intra-extracapillary water exchange in human myocardium using Feruglose: First clinical results in patients with coronary artery disease. Wacker CM; Wiesmann F; Bock M; Jakob P; Sandstede JJ; Lehning A; Ertl G; Schad LR; Haase A; Bauer WR Magn Reson Med; 2002 May; 47(5):1013-6. PubMed ID: 11979582 [TBL] [Abstract][Full Text] [Related]
39. Inversion recovery EPI of bolus transit in rat myocardium using intravascular and extravascular gadolinium-based MR contrast media: dose effects on peak signal enhancement. Wendland MF; Saeed M; Yu KK; Roberts TP; Lauerma K; Derugin N; Varadarajan J; Watson AD; Higgins CB Magn Reson Med; 1994 Sep; 32(3):319-29. PubMed ID: 7984064 [TBL] [Abstract][Full Text] [Related]
40. Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease: insights from cardiovascular magnetic resonance and positron emission tomography. Karamitsos TD; Leccisotti L; Arnold JR; Recio-Mayoral A; Bhamra-Ariza P; Howells RK; Searle N; Robson MD; Rimoldi OE; Camici PG; Neubauer S; Selvanayagam JB Circ Cardiovasc Imaging; 2010 Jan; 3(1):32-40. PubMed ID: 19920032 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]