These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 10470757)

  • 1. Semicontinuous cardiac output monitoring using a neural network.
    Healey C; Orr J; Westenskow D
    Crit Care Med; 1999 Aug; 27(8):1505-10. PubMed ID: 10470757
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors.
    Medin DL; Brown DT; Wesley R; Cunnion RE; Ognibene FP
    J Crit Care; 1998 Dec; 13(4):184-9. PubMed ID: 9869545
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous thermodilution cardiac output: agreement with Fick and bolus thermodilution methods.
    Thrush D; Downs JB; Smith RA
    J Cardiothorac Vasc Anesth; 1995 Aug; 9(4):399-404. PubMed ID: 7579109
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac output minute to minute with a standard pulmonary artery catheter, without fluid overload?
    Tremper KK
    Crit Care Med; 1999 Aug; 27(8):1665-6. PubMed ID: 10470789
    [No Abstract]   [Full Text] [Related]  

  • 5. Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study.
    Haller M; Zöllner C; Briegel J; Forst H
    Crit Care Med; 1995 May; 23(5):860-6. PubMed ID: 7736744
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    Boldt J; Menges T; Wollbrück M; Hammermann H; Hempelmann G
    Crit Care Med; 1994 Dec; 22(12):1913-8. PubMed ID: 7988126
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous cardiac output and mixed venous oxygen saturation monitoring.
    Cariou A; Monchi M; Dhainaut JF
    J Crit Care; 1998 Dec; 13(4):198-213. PubMed ID: 9869547
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system.
    Thierry S; Thebert D; Brocas E; Razzaghi F; Van De Louw A; Loisance D; Teboul JL
    Intensive Care Med; 2003 Nov; 29(11):2096-9. PubMed ID: 13680117
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison between cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model.
    Rupérez M; López-Herce J; García C; Sánchez C; García E; Vigil D
    Pediatr Cardiol; 2004; 25(2):119-23. PubMed ID: 14681741
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.
    Breukers RM; Sepehrkhouy S; Spiegelenberg SR; Groeneveld AB
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig.
    Yang XX; Critchley LA; Joynt GM
    Anesth Analg; 2011 Jan; 112(1):70-7. PubMed ID: 21127281
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous thermodilution cardiac output measurement in intensive care unit patients.
    Yelderman ML; Ramsay MA; Quinn MD; Paulsen AW; McKown RC; Gillman PH
    J Cardiothorac Vasc Anesth; 1992 Jun; 6(3):270-4. PubMed ID: 1610988
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.
    Manecke GR; Auger WR
    J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):3-7. PubMed ID: 17289472
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a continuous cardiac output and mixed venous oxygen saturation catheter in critically ill surgical patients.
    Burchell SA; Yu M; Takiguchi SA; Ohta RM; Myers SA
    Crit Care Med; 1997 Mar; 25(3):388-91. PubMed ID: 9118651
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a new continuous thermodilution cardiac output monitor in cardiac surgical patients: a prospective criterion standard study.
    Zöllner C; Polasek J; Kilger E; Pichler B; Jaenicke U; Briegel J; Vetter HO; Haller M
    Crit Care Med; 1999 Feb; 27(2):293-8. PubMed ID: 10075052
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Systematic error of cardiac output measured by bolus thermodilution with a pulmonary artery catheter compared with that measured by an aortic flow probe in a pig model.
    Yang XX; Critchley LA; Rowlands DK; Fang Z; Huang L
    J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1133-9. PubMed ID: 24035141
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of cardiac output by transpulmonary arterial thermodilution using a long radial artery catheter. A comparison with intermittent pulmonary artery thermodilution.
    Orme RM; Pigott DW; Mihm FG
    Anaesthesia; 2004 Jun; 59(6):590-4. PubMed ID: 15144300
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous thermodilution cardiac output measurement in sheep.
    Yelderman M; Quinn MD; McKown RC; Eberhart RC; Dollar ML
    J Thorac Cardiovasc Surg; 1992 Aug; 104(2):315-20. PubMed ID: 1495292
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous invasive cardiac output monitoring--the Baxter/Edwards Critical-Care Swan Ganz IntelliCath and Viligance system.
    Munro HM; Wood CE; Taylor BL; Smith GB
    Clin Intensive Care; 1994; 5(2):52-5. PubMed ID: 10147254
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology.
    Breukers RB; Jansen JR
    Acta Anaesthesiol Scand; 2004 May; 48(5):658-61. PubMed ID: 15101866
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.