94 related articles for article (PubMed ID: 10472827)
1. Penetrating bladder injury caused by a medially placed acetabular screw.
Kinmont JC
J South Orthop Assoc; 1999; 8(2):98-100. PubMed ID: 10472827
[TBL] [Abstract][Full Text] [Related]
2. [The anatomical study of safe zones of the screw fixations in acetabular revision surgery].
Zhang JB; Chen BC; Wang F; Sun R; Zhao BH
Zhonghua Wai Ke Za Zhi; 2009 May; 47(9):693-6. PubMed ID: 19615241
[TBL] [Abstract][Full Text] [Related]
3. Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty.
Wasielewski RC; Cooperstein LA; Kruger MP; Rubash HE
J Bone Joint Surg Am; 1990 Apr; 72(4):501-8. PubMed ID: 2324135
[TBL] [Abstract][Full Text] [Related]
4. Safe screw placement in acetabular revision surgery.
Meldrum R; Johansen RL
J Arthroplasty; 2001 Dec; 16(8):953-60. PubMed ID: 11740748
[TBL] [Abstract][Full Text] [Related]
5. Neurovascular injuries in acetabular reconstruction cage surgery: an anatomical study.
Lavernia CJ; Cook CC; Hernandez RA; Sierra RJ; Rossi MD
J Arthroplasty; 2007 Jan; 22(1):124-32. PubMed ID: 17197319
[TBL] [Abstract][Full Text] [Related]
6. Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up.
Zwartelé RE; Olsthoorn PG; Pöll RG; Brand R; Doets HC
Arch Orthop Trauma Surg; 2008 Dec; 128(12):1379-86. PubMed ID: 18758793
[TBL] [Abstract][Full Text] [Related]
7. Does ischial screw fixation improve mechanical stability in revision total hip arthroplasty?
Meneghini RM; Stultz AD; Watson JS; Ziemba-Davis M; Buckley CA
J Arthroplasty; 2010 Oct; 25(7):1157-61. PubMed ID: 19679432
[TBL] [Abstract][Full Text] [Related]
8. [Treatment of dysplastic acetabulum using total hip arthroplasty: our intermediate-term results].
Cichý Z
Acta Chir Orthop Traumatol Cech; 2006 Oct; 73(5):340-4. PubMed ID: 17140516
[TBL] [Abstract][Full Text] [Related]
9. Acetabular anatomy and transacetabular screw fixation at the high hip center.
Wasielewski RC; Galat DD; Sheridan KC; Rubash HE
Clin Orthop Relat Res; 2005 Sep; 438():171-6. PubMed ID: 16131887
[TBL] [Abstract][Full Text] [Related]
10. [Acetabular component centralization in total hip arthroplasty for acetabular dysplasia].
Shi ZC; Li ZR; Sun W
Zhonghua Wai Ke Za Zhi; 2004 Dec; 42(23):1412-5. PubMed ID: 15733451
[TBL] [Abstract][Full Text] [Related]
11. Re: Safe screw placement in acetabular revision surgery.
Matta J
J Arthroplasty; 2002 Sep; 17(6):810; discussion 810-11. PubMed ID: 12216041
[No Abstract] [Full Text] [Related]
12. [Early primary total hip arthroplasty for acetabular fractures in elderly patients].
Simko P; Braunsteiner T; Vajcziková S
Acta Chir Orthop Traumatol Cech; 2006 Aug; 73(4):275-82. PubMed ID: 17026887
[TBL] [Abstract][Full Text] [Related]
13. Radiographic evaluation of screw position in revision total hip arthroplasty.
Galat DD; Petrucci JA; Wasielewski RC
Clin Orthop Relat Res; 2004 Feb; (419):124-9. PubMed ID: 15021142
[TBL] [Abstract][Full Text] [Related]
14. Implant survival after primary total hip arthroplasty due to childhood hip disorders: results from the Danish Hip Arthroplasty Registry.
Thillemann TM; Pedersen AB; Johnsen SP; Søballe K;
Acta Orthop; 2008 Dec; 79(6):769-76. PubMed ID: 19085493
[TBL] [Abstract][Full Text] [Related]
15. [Delayed neuropathy of the sciatic nerve after total hip replacement with an acetabular reinforcement ring].
Schuh A; Riedel F; Craiovan B; Zeiler G
Zentralbl Chir; 2003 Oct; 128(10):871-3. PubMed ID: 14628239
[TBL] [Abstract][Full Text] [Related]
16. Periprosthetic acetabular bone loss using a constrained acetabular component.
Ito H; Matsuno T
Arch Orthop Trauma Surg; 2004 Mar; 124(2):137-9. PubMed ID: 14652779
[TBL] [Abstract][Full Text] [Related]
17. Bladder tear during revision total hip arthroplasty.
Grauer JN; Halim A; Keggi KJ
Am J Orthop (Belle Mead NJ); 2014 Aug; 43(8):E185-8. PubMed ID: 25136877
[TBL] [Abstract][Full Text] [Related]
18. [Reconstruction of the acetabulum during replacement of the aseptically loosened polyethylene cup].
Koudela K; Malotín T
Acta Chir Orthop Traumatol Cech; 2001; 68(3):162-7. PubMed ID: 11706538
[TBL] [Abstract][Full Text] [Related]
19. [Application of acetabulum reinforcement ring for reconstructing acetabular defects in artificial hip replacement].
Han W; Zhang H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Feb; 23(2):201-4. PubMed ID: 19275103
[TBL] [Abstract][Full Text] [Related]
20. Vesico-hip fistula from bladder puncture with subsequent infected total hip arthroplasty.
Vishwanath J; Ng YP; Teo YS; De SD
J Arthroplasty; 2007 Sep; 22(6):939-41. PubMed ID: 17826290
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]