These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
325 related articles for article (PubMed ID: 10473203)
1. Monte Carlo calculations of the ionization chamber wall correction factors for 192Ir and 60Co gamma rays and 250 kV x-rays for use in calibration of 192Ir HDR brachytherapy sources. Ferreira IH; de Almeida CE; Marre D; Marechal MH; Bridier A; Chavaudra J Phys Med Biol; 1999 Aug; 44(8):1897-904. PubMed ID: 10473203 [TBL] [Abstract][Full Text] [Related]
2. Experimental derivation of wall correction factors for ionization chambers used in high dose rate 192Ir source calibration. Maréchal MH; de Almeida CE; Ferreira IH; Sibata CH Med Phys; 2002 Jan; 29(1):1-5. PubMed ID: 11833542 [TBL] [Abstract][Full Text] [Related]
3. In-water calibration of PDR 192Ir brachytherapy sources with an NE2571 ionization chamber. Reynaert N; Verhaegen F; Thierens H Phys Med Biol; 1998 Aug; 43(8):2095-107. PubMed ID: 9725592 [TBL] [Abstract][Full Text] [Related]
4. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty. van Dijk E; Kolkman-Deurloo IK; Damen PM Med Phys; 2004 Oct; 31(10):2826-33. PubMed ID: 15543790 [TBL] [Abstract][Full Text] [Related]
5. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system. Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095 [TBL] [Abstract][Full Text] [Related]
6. Study of encapsulated 170Tm sources for their potential use in brachytherapy. Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484 [TBL] [Abstract][Full Text] [Related]
7. Comparison of 192Ir air kerma calibration coefficients derived at ARPANSA using the interpolation method and at the National Physical Laboratory using a direct measurement. Butler D; Haworth A; Sander T; Todd S Australas Phys Eng Sci Med; 2008 Dec; 31(4):332-8. PubMed ID: 19239060 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons. Ballester F; Granero D; Pérez-Calatayud J; Melhus CS; Rivard MJ Med Phys; 2009 Sep; 36(9):4250-6. PubMed ID: 19810499 [TBL] [Abstract][Full Text] [Related]
9. In-air calibration of an HDR 192Ir brachytherapy source using therapy ion chambers. Patel NP; Majumdar B; Vijiyan V; Hota PK J Cancer Res Ther; 2005; 1(4):213-20. PubMed ID: 17998656 [TBL] [Abstract][Full Text] [Related]
10. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method. Ubrich F; Wulff J; Engenhart-Cabillic R; Zink K Z Med Phys; 2014 May; 24(2):138-52. PubMed ID: 24021956 [TBL] [Abstract][Full Text] [Related]
11. Correction factors for Farmer-type chambers for absorbed dose determination in 60Co and 192Ir brachytherapy dosimetry. Tölli H; Johansson KA Phys Med Biol; 1998 Nov; 43(11):3171-81. PubMed ID: 9832009 [TBL] [Abstract][Full Text] [Related]
12. A radiation quality correction factor k for well-type ionization chambers for the measurement of the reference air kerma rate of (60)Co HDR brachytherapy sources. Schüller A; Meier M; Selbach HJ; Ankerhold U Med Phys; 2015 Jul; 42(7):4285-94. PubMed ID: 26133626 [TBL] [Abstract][Full Text] [Related]
13. Air-kerma strength determination of an HDR Smith BR; Micka JA; Aima M; DeWerd LA; Culberson WS Med Phys; 2017 Jan; 44(1):311-320. PubMed ID: 28102953 [TBL] [Abstract][Full Text] [Related]
14. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy. Campos LT; de Almeida CE PLoS One; 2015; 10(9):e0139032. PubMed ID: 26418559 [TBL] [Abstract][Full Text] [Related]
15. Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources. Tölli H; Johansson KA Phys Med Biol; 1998 Nov; 43(11):3183-94. PubMed ID: 9832010 [TBL] [Abstract][Full Text] [Related]
16. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV). Tedgren AC; Hedman A; Grindborg JE; Carlsson GA Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372 [TBL] [Abstract][Full Text] [Related]
17. On the accuracy of techniques for obtaining the calibration coefficient N(K) of 192Ir HDR brachytherapy sources. Mainegra-Hing E; Rogers DW Med Phys; 2006 Sep; 33(9):3340-7. PubMed ID: 17022230 [TBL] [Abstract][Full Text] [Related]
18. IRIDIUM-192 RADIOTHERAPY BENEFITS IN THE MANAGEMENT OF GYNECOLOGICAL TUMORS. Ivankova VS; Domina EA; Khrulenko TV; Baranovska LM; Hrinchenko OO Probl Radiac Med Radiobiol; 2020 Dec; 25():569-578. PubMed ID: 33361862 [TBL] [Abstract][Full Text] [Related]
19. Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in 60Co gamma beams. Laitano RF; Toni MP; Pimpinella M; Bovi M Phys Med Biol; 2002 Jul; 47(14):2411-31. PubMed ID: 12171331 [TBL] [Abstract][Full Text] [Related]
20. Comparison of organ doses for patients undergoing balloon brachytherapy of the breast with HDR 192Ir or electronic sources using monte carlo simulations in a heterogeneous human phantom. Mille MM; Xu XG; Rivard MJ Med Phys; 2010 Feb; 37(2):662-71. PubMed ID: 20229875 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]