These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 10473208)

  • 21. A simulation study of the effects of torso inhomogeneities on electrocardiographic potentials, using realistic heart and torso models.
    Gulrajani RM; Mailloux GE
    Circ Res; 1983 Jan; 52(1):45-56. PubMed ID: 6848209
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison between electrocardiographic and magnetocardiographic inverse solutions using the boundary element method.
    Hren R; Zhang X; Stroink G
    Med Biol Eng Comput; 1996 Mar; 34(2):110-4. PubMed ID: 8733546
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of dipole position, orientation and noise on the accuracy of EEG source localization.
    Whittingstall K; Stroink G; Gates L; Connolly JF; Finley A
    Biomed Eng Online; 2003 Jun; 2():14. PubMed ID: 12807534
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A realistic torso model for magnetocardiography.
    van Oosterom A; Huiskamp GJ
    Int J Card Imaging; 1991; 7(3-4):169-76. PubMed ID: 1820398
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Magnetic source imaging in the human heart: estimating cardiac electrical sources from simulated and measured magnetocardiogram data.
    Wach P; Tilg B; Lafer G; Rucker W
    Med Biol Eng Comput; 1997 May; 35(3):157-66. PubMed ID: 9246845
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Bioelectromagnetic localization of a pacing catheter in the heart.
    Pesola K; Nenonen J; Fenici R; Lötjönen J; Mäkijärvi M; Fenici P; Korhonen P; Lauerma K; Valkonen M; Toivonen L; Katila T
    Phys Med Biol; 1999 Oct; 44(10):2565-78. PubMed ID: 10533929
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Construction and modeling of a physical thoracic phantom for magnetic field and body surface potential mapping].
    Tenner U; Brauer H; Haueisen J; Nowak H; Leder U
    Biomed Tech (Berl); 1997; 42 Suppl():401-2. PubMed ID: 9517210
    [No Abstract]   [Full Text] [Related]  

  • 28. Probability-based current dipole localization from biomagnetic fields.
    Scholz B; Schwierz G
    IEEE Trans Biomed Eng; 1994 Aug; 41(8):735-42. PubMed ID: 7927396
    [TBL] [Abstract][Full Text] [Related]  

  • 29. On the algorithm for computing body surface Laplacians in an inhomogeneous volume conductor of arbitrary shape.
    Wang Y; Wu D; He B
    IEEE Trans Biomed Eng; 1998 Jan; 45(1):131-3. PubMed ID: 9444849
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Influence of head models on neuromagnetic fields and inverse source localizations.
    Ramon C; Haueisen J; Schimpf PH
    Biomed Eng Online; 2006 Oct; 5():55. PubMed ID: 17059601
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Geometrical constraint of sources in noninvasive localization of premature ventricular contractions.
    Svehlikova J; Teplan M; Tysler M
    J Electrocardiol; 2018; 51(3):370-377. PubMed ID: 29779525
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A computer model for the study of electrical current flow in the human thorax.
    Johnson CR; MacLeod RS; Ershler PR
    Comput Biol Med; 1992 Sep; 22(5):305-23. PubMed ID: 1424577
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of anisotropic electrical conductivity in white matter tissue on the EEG/MEG forward and inverse solution. A high-resolution whole head simulation study.
    Güllmar D; Haueisen J; Reichenbach JR
    Neuroimage; 2010 May; 51(1):145-63. PubMed ID: 20156576
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Phantom validation of multichannel magnetocardiography source localization.
    Fenici R; Brisinda D; Nenonen J; Fenici P
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):426-30. PubMed ID: 12687859
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Lobe based image reconstruction in Electrical Impedance Tomography.
    Schullcke B; Gong B; Krueger-Ziolek S; Tawhai M; Adler A; Mueller-Lisse U; Moeller K
    Med Phys; 2017 Feb; 44(2):426-436. PubMed ID: 28121374
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Multichannel magnetocardiographic measurements with a physical thorax phantom.
    Pesola K; Tenner U; Nenonen J; Endt P; Brauer H; Leder U; Katila T
    Med Biol Eng Comput; 1999 Jan; 37(1):2-7. PubMed ID: 10396834
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Postprocessing of 3-D current density reconstruction results with equivalent ellipsoids.
    Ziolkowski M; Haueisen J; Leder U
    IEEE Trans Biomed Eng; 2002 Nov; 49(11):1379-84. PubMed ID: 12450370
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The effect of torso impedance on epicardial and body surface potentials: a modeling study.
    Buist ML; Pullan AJ
    IEEE Trans Biomed Eng; 2003 Jul; 50(7):816-24. PubMed ID: 12848349
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A MATHEMATICAL-PHYSICAL MODEL OF THE GENESIS OF THE ELECTROCARDIOGRAM.
    GELERNTER HL; SWIHART JC
    Biophys J; 1964 Jul; 4(4):285-301. PubMed ID: 14197788
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Non-dipolarity of heart potentials estimated by magnetocardiography in normal subjects.
    Izumida N; Asano Y; Hosaki J; Hiyoshi Y; Sakurada H; Motomiya T; Kawano S; Sawanobori T; Hiraoka M
    Jpn Heart J; 1998 Nov; 39(6):731-42. PubMed ID: 10089935
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.