These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

201 related articles for article (PubMed ID: 10473682)

  • 1. Method for Cross-sectional Transmission Electron Microscopy Specimen Preparation of Composite Materials Using a Dedicated Focused Ion Beam System.
    Yaguchi T; Kamino T; Ishitani T; Urao R
    Microsc Microanal; 1999 Sep; 5(5):365-370. PubMed ID: 10473682
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of neon focused ion beam milling for TEM sample preparation.
    Pekin TC; Allen FI; Minor AM
    J Microsc; 2016 Oct; 264(1):59-63. PubMed ID: 27172066
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Post-thinning using Ar ion-milling system for transmission electron microscopy specimens prepared by focused ion beam system.
    Lee MH; Kim KH
    J Microsc; 2016 Mar; 261(3):243-8. PubMed ID: 26457668
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparing Xe
    Zhong X; Wade CA; Withers PJ; Zhou X; Cai C; Haigh SJ; Burke MG
    J Microsc; 2021 May; 282(2):101-112. PubMed ID: 33210738
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sample preparation toward seamless 3D imaging technique from micrometer to nanometer scale.
    Miyake A; Matsuno J; Toh S
    Microscopy (Oxf); 2014 Nov; 63 Suppl 1():i24-i25. PubMed ID: 25359821
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Site-specific specimen preparation by focused ion beam milling for transmission electron microscopy of metal matrix composites.
    Gasser P; Klotz UE; Khalid FA; Beffort O
    Microsc Microanal; 2004 Apr; 10(2):311-6. PubMed ID: 15306057
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Specimen preparation for high-resolution transmission electron microscopy using focused ion beam and Ar ion milling.
    Sasaki H; Matsuda T; Kato T; Muroga T; Iijima Y; Saitoh T; Iwase F; Yamada Y; Izumi T; Shiohara Y; Hirayama T
    J Electron Microsc (Tokyo); 2004; 53(5):497-500. PubMed ID: 15582954
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrathin specimen preparation by a low-energy Ar-ion milling method.
    Mitome M
    Microscopy (Oxf); 2013 Apr; 62(2):321-6. PubMed ID: 23155112
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Method of Ga removal from a specimen on a microelectromechanical system-based chip for in-situ transmission electron microscopy.
    Kwon Y; An BS; Shin YJ; Yang CW
    Appl Microsc; 2020 Oct; 50(1):22. PubMed ID: 33580423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of TEM samples of an Mg-Al alloy prepared using FIB milling at the operating voltages of 10 kV and 40 kV.
    Kamino T; Yaguchi T; Kuroda Y; Ohnishi T; Ishitani T; Miyahara Y; Horita Z
    J Electron Microsc (Tokyo); 2004; 53(5):459-63. PubMed ID: 15582947
    [TBL] [Abstract][Full Text] [Related]  

  • 11. High-quality TEM specimen preparation for lithium-ion conducting solid electrolytes by low-energy ion milling.
    Hu X; Lu Y; Chen Y; Wang Z; Huang Y; Liu W; Yu Y
    Ultramicroscopy; 2023 Nov; 253():113823. PubMed ID: 37536123
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improvements in performance of focused ion beam cross-sectioning: aspects of ion-sample interaction.
    Ishitani T; Umemura K; Ohnishi T; Yaguchi T; Kamino T
    J Electron Microsc (Tokyo); 2004; 53(5):443-9. PubMed ID: 15582945
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.
    Yaguchi T; Kamino T; Sasaki M; Barbezat G; Urao R
    Microsc Microanal; 2000 May; 6(3):218-223. PubMed ID: 10790490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A study of the damage on FIB-prepared TEM samples of AlxGa1-xAs.
    Yabuuchi Y; Tametou S; Okano T; Inazato S; Sadayama S; Yamamoto Y; Iwasaki K; Sugiyama Y
    J Electron Microsc (Tokyo); 2004; 53(5):471-7. PubMed ID: 15582949
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combining Ar ion milling with FIB lift-out techniques to prepare high quality site-specific TEM samples.
    Huang Z
    J Microsc; 2004 Sep; 215(Pt 3):219-23. PubMed ID: 15312185
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Two-dimensional and 3-dimensional analysis of bone/dental implant interfaces with the use of focused ion beam and electron microscopy.
    Giannuzzi LA; Phifer D; Giannuzzi NJ; Capuano MJ
    J Oral Maxillofac Surg; 2007 Apr; 65(4):737-47. PubMed ID: 17368372
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In situ characterization of resin-dentin interfaces using conventional vs. cryofocused ion-beam milling.
    Bakhsh TA; Sadr A; Mandurah MM; Shimada Y; Zakaria O; Tagami J
    Dent Mater; 2015 Jul; 31(7):833-44. PubMed ID: 25986333
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Plan-view transmission electron microscopy specimen preparation for atomic layer materials using a focused ion beam approach.
    Lee LH; Yu CH; Wei CY; Lee PC; Huang JS; Wen CY
    Ultramicroscopy; 2019 Feb; 197():95-99. PubMed ID: 30537672
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved focused ion beam target preparation of (S)TEM specimen--a method for obtaining ultrathin lamellae.
    Lechner L; Biskupek J; Kaiser U
    Microsc Microanal; 2012 Apr; 18(2):379-84. PubMed ID: 22436335
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.