These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 10475488)

  • 1. A ventricular assist device powered by conditioned skeletal muscle.
    Whalen RL; Richards CL; Lim GW; Sherman CW; Norman JC; Bearnson GB; Burns GL; Olsen DB
    Ann Thorac Surg; 1999 Aug; 68(2):780-4. PubMed ID: 10475488
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A compressive type skeletal muscle pump as a biomechanical energy source.
    Mizuhara H; Oda T; Koshiji T; Ikeda T; Nishimura K; Nomoto S; Matsuda K; Tsutsui N; Kanda K; Ban T
    ASAIO J; 1996; 42(5):M637-41. PubMed ID: 8944958
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanical advantage of skeletal muscle as a cardiac assist power source.
    Farrar DJ; Reichenbach SH; Hill JD
    ASAIO J; 1995; 41(3):M481-4. PubMed ID: 8573851
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of a biomechanical counterpulsation device powered by skeletal muscle for right heart assist.
    Doi T; Mitsui T; Matsushita S; Tsutsui T; Hori M
    ASAIO Trans; 1990; 36(3):M389-92. PubMed ID: 2252707
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vivo measurements of skeletal muscle in a linear configuration powering a hydraulically actuated VAD.
    Farrar DJ; Reichenbach SH; Hill JD
    ASAIO J; 1994; 40(3):M309-13. PubMed ID: 8555530
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Double chamber ventricular assist device with a roller screw linear actuator driven by left and right latissimus dorsi muscles.
    Takatani S; Takami Y; Nakazawa T; Jacobs G; Nose Y
    ASAIO J; 1995; 41(3):M475-80. PubMed ID: 8573850
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A muscle powered cardiac assist device for right ventricular support: total assist or partial assist?
    Sakakibara N; Watanabe G; Misaki T; Mukai A; Tsubota M; Takemura H; Ohtake Y; Iwa T
    ASAIO Trans; 1990; 36(3):M372-5. PubMed ID: 2252702
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a compressive-type skeletal muscle pump for cardiac assistance.
    Mizuhara H; Koshiji T; Nishimura K; Nomoto S; Matsuda K; Ban T
    Ann Thorac Surg; 1999 Jan; 67(1):105-11. PubMed ID: 10086533
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Muscle powered blood pump: design and initial test results.
    Trumble DR; Magovern JA
    ASAIO J; 1999; 45(3):178-82. PubMed ID: 10360719
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Linear performance characteristics of latissimus dorsi muscle: potential for cardiac assistance.
    Gustafson KJ; Guilbeau EJ; Sweeney JD
    ASAIO J; 2003; 49(5):572-7. PubMed ID: 14524567
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The muscle-powered dual-chamber counterpulsator: rheologically superior implantable cardiac assist device.
    Kochamba G; Desrosiers C; Dewar M; Chiu RC
    Ann Thorac Surg; 1988 Jun; 45(6):620-5. PubMed ID: 3259863
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can angiogenesis induced by chronic electrical stimulation enhance latissimus dorsi muscle flap survival for application in cardiomyoplasty?
    Overgoor ML; Carroll SM; Papanicolau G; Carroll CM; Ustüner TE; Stremel RW; Anderson GL; Franken RJ; Kon M; Barker JH
    Plast Reconstr Surg; 2003 Jan; 111(1):178-88. PubMed ID: 12496579
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anabolic steroids (metenolone) improve muscle performance and hemodynamic characteristics in cardiomyoplasty.
    Fritzsche D; Krakor R; Asmussen G; Widera R; Caffier P; Berkei J; Cesla M
    Ann Thorac Surg; 1995 Apr; 59(4):961-9; discussion 969-70. PubMed ID: 7695425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Potential mechanisms for muscle-powered cardiac support.
    Trumble DR
    Artif Organs; 2011 Jul; 35(7):715-20. PubMed ID: 21599720
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo performance of a muscle-powered drive system for implantable blood pumps.
    Trumble DR; Melvin DB; Dean DA; Magovern JA
    ASAIO J; 2008; 54(3):227-32. PubMed ID: 18496270
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Latency of skeletal muscle contraction after pulse train stimulation: an important factor in correct timing of skeletal muscle cardiac assist devices.
    Letsou GV; Zarif A; Smith A; Hogan J; Lee P; Ariyan S; Baldwin JC; Elefteriades JA
    J Surg Res; 1994 Dec; 57(6):672-6. PubMed ID: 7996844
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Testing of the latissimus dorsi muscle stimulation regimens in the experimental model of thoracic aortomyoplasty].
    Dumcius A; Bavarskis E; Chekanov V; Vysockas V
    Medicina (Kaunas); 2002; 38 Suppl 2():226-9. PubMed ID: 12560668
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Blood supply to the latissimus dorsi muscle and muscle performance during co- or counterpulsatile stimulation for circulatory assist.
    Takagi H; Hirose H; Sasaki E; Mikamo H; Imaizumi M; Hirota T; Bando M; Furuzawa Y; Murakawa S; Mori Y
    Artif Organs; 1997 Aug; 21(8):929-34. PubMed ID: 9247183
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sustained skeletal muscle power for cardiac assist devices: implications of metabolic constraints.
    Reichenbach SH; Egrie GD; Marinache SM; Gustafson KJ; Farrar DJ; Hill JD
    ASAIO J; 2001; 47(5):541-7. PubMed ID: 11575834
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ex vivo performance of muscle powered cardiac assist device: potential for right ventricular support.
    Sakakibara N; Takemura H; Tedoriya T; Kawasuji M; Misaki T; Iwa T
    J Card Surg; 1991 Mar; 6(1 Suppl):171-4. PubMed ID: 1807500
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.