These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 10476295)

  • 21. Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate.
    Ebraheim NA; Gomez C; Ramineni SK; Liu J
    J Trauma; 2009 Apr; 66(4):1152-7. PubMed ID: 19359929
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Ipsilateral fractures of the proximal femur and the femoral shaft].
    Douša P; Bartoníček J; Pavelka T; Luňáček L
    Acta Chir Orthop Traumatol Cech; 2010 Oct; 77(5):378-88. PubMed ID: 21040649
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A retrospective review of the Dall-Miles plate for periprosthetic femoral fractures: twenty-seven cases and a review of the literature.
    Dargan D; Jenkinson MJ; Acton JD
    Injury; 2014 Dec; 45(12):1958-63. PubMed ID: 25225174
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Limited open reduction and double plates internal fixation for treatment of Vancouver type B1 periprosthetic femoral fracture after hip arthroplasty].
    Zhang Y; Fan X; Liu Y; Shao J; Tang J; Liu S; Yang T; Zhang C
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1428-31. PubMed ID: 24640358
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Periprosthetic Femoral Fractures after Total Hip Replacement: Our Results and Treatment Complications].
    Pavelka T; Salášek M; Weisová D
    Acta Chir Orthop Traumatol Cech; 2017; 84(1):52-58. PubMed ID: 28253947
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dall-Miles plates for periprosthetic femoral fractures. A critical review of 16 cases.
    Tsiridis E; Haddad FS; Gie GA
    Injury; 2003 Feb; 34(2):107-10. PubMed ID: 12565016
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
    Krbec M; Motycka J; Lunácek L; Dousa P
    Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. Surgical Technique.
    Ricci WM; Bolhofner BR; Loftus T; Cox C; Mitchell S; Borrelli J
    J Bone Joint Surg Am; 2006 Sep; 88 Suppl 1 Pt 2():275-82. PubMed ID: 16951099
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Use of Locking Plate and Strut Onlay Allografts for Periprosthetic Fracture Around Well-Fixed Femoral Components.
    Kim YH; Mansukhani SA; Kim JS; Park JW
    J Arthroplasty; 2017 Jan; 32(1):166-170. PubMed ID: 27407037
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of reduction of ipsilateral femoral neck and shaft fractures--an analysis of various internal fixation strategies.
    Bedi A; Karunakar MA; Caron T; Sanders RW; Haidukewych GJ
    J Orthop Trauma; 2009 Apr; 23(4):249-53. PubMed ID: 19318867
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant.
    Ricci WM; Bolhofner BR; Loftus T; Cox C; Mitchell S; Borrelli J
    J Bone Joint Surg Am; 2005 Oct; 87(10):2240-5. PubMed ID: 16203889
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Mennen plate fixation for fracture of the femoral shaft with ipsilateral total hip and knee arthroplasties.
    Dave DJ; Koka SR; James SE
    J Arthroplasty; 1995 Feb; 10(1):113-5. PubMed ID: 7730821
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Treatment of periprosthetic femoral fractures after femoral revision using a long stem.
    Kim Y; Tanaka C; Tada H; Kanoe H; Shirai T
    BMC Musculoskelet Disord; 2015 May; 16():113. PubMed ID: 25958328
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Treatment of interprosthetic fractures of the femur.
    Hou Z; Moore B; Bowen TR; Irgit K; Matzko ME; Strohecker KA; Smith WR
    J Trauma; 2011 Dec; 71(6):1715-9. PubMed ID: 22182879
    [TBL] [Abstract][Full Text] [Related]  

  • 35. NCB-plating in the treatment of geriatric and periprosthetic femoral fractures.
    El-Zayat BF; Ruchholtz S; Efe T; Fuchs-Winkelmann S; Krüger A; Kreslo D; Zettl R
    Orthop Traumatol Surg Res; 2012 Nov; 98(7):765-72. PubMed ID: 23098773
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Use of a cerclage cable-plate system to stabilize a periprosthetic femoral fracture after total hip replacement in a dog.
    Carvajal JL; Kim SE; Pozzi A
    Vet Surg; 2019 Apr; 48(3):437-443. PubMed ID: 30820982
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Peri-prosthetic femoral shaft fractures treated with plate and cable fixation.
    Haddad FS
    Injury; 2000 Apr; 31(3):213. PubMed ID: 10809603
    [No Abstract]   [Full Text] [Related]  

  • 38. Reversed Contralateral LISS Plate for Vancouver B1 Periprosthetic Femoral Shaft Fractures.
    Russo M; Malekzadeh AS; Hampton C; Hymes R; Schwartzbach C; Schulman J
    Orthopedics; 2015 Jun; 38(6):e467-72. PubMed ID: 26091218
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Locking attachment plate fixation around a well-fixed stem in periprosthetic femoral shaft fractures.
    Kim MB; Cho JW; Lee YH; Shon WY; Park JW; Kim J; Oh JK
    Arch Orthop Trauma Surg; 2017 Sep; 137(9):1193-1200. PubMed ID: 28689273
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Osteosynthesis of periprosthetic type A and B femoral fractures using an unlocked plate with integrated cerclage cable and trochanteric hook: A multicenter retrospective study of 45 patients with mean follow-up of 20 months.
    Gavanier B; Houfani F; Dumoulin Q; Bernard E; Mangin M; Mainard D
    Injury; 2017 Dec; 48(12):2827-2832. PubMed ID: 29100663
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.