These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
170 related articles for article (PubMed ID: 10481404)
1. [Evaluation of a new screening assay kit for the combined detection of HIV p24 antigen and antibody--comparison of the performance of the new kit and HIV antibody assay kits]. Hayashi T; Watanabe S; Kondo M; Saito T; Imai M Kansenshogaku Zasshi; 1999 Jul; 73(7):681-8. PubMed ID: 10481404 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra. Weber B; Berger A; Rabenau H; Doerr HW J Clin Microbiol; 2002 Apr; 40(4):1420-6. PubMed ID: 11923367 [TBL] [Abstract][Full Text] [Related]
3. [Evaluation of an HIV screening assay kit for the combined detection of anti-HIV-1/2 antibodies and HIV p24 antigen]. Shima T; Kondo M; Saito T; Kawata K; Ito A; Sakamoto M; Sagara H; Imai M Kansenshogaku Zasshi; 2001 Dec; 75(12):1014-24. PubMed ID: 11806135 [TBL] [Abstract][Full Text] [Related]
4. Comparative evaluation of the VIDAS HIV DUO Ultra assay for combined detection of HIV-1 antigen and antibodies to HIV. Bourlet T; Pretis C; Pillet S; Lesenechal M; Piche J; Pozzetto B J Virol Methods; 2005 Aug; 127(2):165-7. PubMed ID: 15967238 [TBL] [Abstract][Full Text] [Related]
5. Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity. Weber B; Gürtler L; Thorstensson R; Michl U; Mühlbacher A; Bürgisser P; Villaescusa R; Eiras A; Gabriel C; Stekel H; Tanprasert S; Oota S; Silvestre MJ; Marques C; Ladeira M; Rabenau H; Berger A; Schmitt U; Melchior W J Clin Microbiol; 2002 Jun; 40(6):1938-46. PubMed ID: 12037046 [TBL] [Abstract][Full Text] [Related]
6. Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays. Weber B; Fall EH; Berger A; Doerr HW J Clin Microbiol; 1998 Aug; 36(8):2235-9. PubMed ID: 9665998 [TBL] [Abstract][Full Text] [Related]
7. Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test. Brust S; Duttmann H; Feldner J; Gürtler L; Thorstensson R; Simon F J Virol Methods; 2000 Nov; 90(2):153-65. PubMed ID: 11064116 [TBL] [Abstract][Full Text] [Related]
8. [Investigation of a new HIV-1 p24 antigen detection kit based on the enzyme-linked fluorescent immunoassay]. Hayashi T; Saito T; Kondo M; Watanabe S; Imai M Kansenshogaku Zasshi; 2000 Sep; 74(9):709-15. PubMed ID: 11068364 [TBL] [Abstract][Full Text] [Related]
9. Seven human immunodeficiency virus (HIV) antigen-antibody combination assays: evaluation of HIV seroconversion sensitivity and subtype detection. Ly TD; Martin L; Daghfal D; Sandridge A; West D; Bristow R; Chalouas L; Qiu X; Lou SC; Hunt JC; Schochetman G; Devare SG J Clin Microbiol; 2001 Sep; 39(9):3122-8. PubMed ID: 11526139 [TBL] [Abstract][Full Text] [Related]
10. Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay. Gürtler L; Mühlbacher A; Michl U; Hofmann H; Paggi GG; Bossi V; Thorstensson R; G-Villaescusa R; Eiras A; Hernandez JM; Melchior W; Donie F; Weber B J Virol Methods; 1998 Nov; 75(1):27-38. PubMed ID: 9820572 [TBL] [Abstract][Full Text] [Related]
11. [Screening tests combined with p24 antigen and anti-HIV antibodies in early detection of HIV-1]. Laperche S; Maniez-Montreuil M; Couroucé AM Transfus Clin Biol; 2000 Jun; 7 Suppl 1():18s-24s. PubMed ID: 10919219 [TBL] [Abstract][Full Text] [Related]
12. Analytical sensitivity of four HIV combined antigen/antibody assays using the p24 WHO standard. Miedouge M; Grèze M; Bailly A; Izopet J J Clin Virol; 2011 Jan; 50(1):57-60. PubMed ID: 20926337 [TBL] [Abstract][Full Text] [Related]
13. Performance comparison of the 4th generation Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA on the EVOLIS™ automated system versus Abbott ARCHITECT HIV Ag/Ab Combo, Ortho Anti-HIV 1+2 EIA on Vitros ECi and Siemens HIV-1/O/2 enhanced on Advia Centaur. Mitchell EO; Stewart G; Bajzik O; Ferret M; Bentsen C; Shriver MK J Clin Virol; 2013 Dec; 58 Suppl 1():e79-84. PubMed ID: 24342482 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of the automated 'Enzymen-Test Anti HIV-1 + 2' and 'Enzymen-Test Anti HIV-1/2 selective' for the combined detection and differentiation of anti-HIV-1 and anti-HIV-2 antibodies. Weber B; Hess G; Koberstein R; Doerr HW J Virol Methods; 1993 Oct; 44(2-3):251-60. PubMed ID: 8263119 [TBL] [Abstract][Full Text] [Related]
15. [Early diagnosis of primary HIV infections: using a combined screening test (p24 antigen and anti-HIV antibodies)]. Yerly S; Simon F; Perrin L Schweiz Med Wochenschr; 1999 Feb; 129(8):319-22. PubMed ID: 10189669 [TBL] [Abstract][Full Text] [Related]
16. A multicentre evaluation of the Elecsys Mühlbacher A; Sauleda S; Piron M; Rietz R; Permpikul P; Klinkicht M; Gloeck M; Imdahl R J Clin Virol; 2019 Mar; 112():45-50. PubMed ID: 30611626 [TBL] [Abstract][Full Text] [Related]
17. Multicenter evaluation of a new rapid automated human immunodeficiency virus antigen detection assay. Weber B; Mühlbacher A; Michl U; Paggi G; Bossi V; Sargento C; Camacho R; Fall EH; Berger A; Schmitt U; Melchior W J Virol Methods; 1999 Mar; 78(1-2):61-70. PubMed ID: 10204697 [TBL] [Abstract][Full Text] [Related]
18. Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays. Kwon JA; Yoon SY; Lee CK; Lim CS; Lee KN; Sung HJ; Brennan CA; Devare SG J Virol Methods; 2006 Apr; 133(1):20-6. PubMed ID: 16313975 [TBL] [Abstract][Full Text] [Related]
19. [Evaluation of a new vesion of the human immunodeficiency virus antigen and antibody combination assay with improved sensitivity in HIV-1 p24 antigen detection]. Sano T; Kondo M; Yoshimura Y; Tachikawa N; Sagara H; Itoda I; Yamanaka K; Sudo K; Kato S; Imai M Kansenshogaku Zasshi; 2013 Jul; 87(4):415-23. PubMed ID: 23984590 [TBL] [Abstract][Full Text] [Related]
20. Could the new HIV combined p24 antigen and antibody assays replace p24 antigen specific assays? Ly TD; Ebel A; Faucher V; Fihman V; Laperche S J Virol Methods; 2007 Jul; 143(1):86-94. PubMed ID: 17395277 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]