These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 10490686)

  • 1. Surface roughness quantification of CoCrMo implant alloys.
    Que L; Topoleski LD
    J Biomed Mater Res; 1999; 48(5):705-11. PubMed ID: 10490686
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints.
    Que L; Topoleski LD; Parks NL
    J Biomed Mater Res; 2000; 53(1):111-8. PubMed ID: 10634960
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Third-body wear of cobalt-chromium-molybdenum implant alloys initiated by bone and poly(methyl methacrylate) particles.
    Que L; Topoleski LD
    J Biomed Mater Res; 2000 Jun; 50(3):322-30. PubMed ID: 10737873
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance assessment of femoral knee components made from cobalt-chromium alloy and oxidized zirconium.
    Brandt JM; Guenther L; O'Brien S; Vecherya A; Turgeon TR; Bohm ER
    Knee; 2013 Dec; 20(6):388-96. PubMed ID: 23583666
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles.
    Mirghany M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):41-50. PubMed ID: 14982345
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparative surface topographical analysis of explanted total knee replacement prostheses: Oxidised zirconium vs cobalt chromium femoral components.
    Kennard E; Scholes SC; Sidaginamale R; Gangadharan R; Weir DJ; Holland J; Deehan D; Joyce TJ
    Med Eng Phys; 2017 Dec; 50():59-64. PubMed ID: 29042144
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis.
    Fabry C; Zietz C; Baumann A; Ehall R; Bader R
    Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2630-2639. PubMed ID: 28528349
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion Damage and Wear Mechanisms in Long-Term Retrieved CoCr Femoral Components for Total Knee Arthroplasty.
    Arnholt CM; MacDonald DW; Malkani AL; Klein GR; Rimnac CM; Kurtz SM; ; Kocagoz SB; Gilbert JL
    J Arthroplasty; 2016 Dec; 31(12):2900-2906. PubMed ID: 27426028
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Wear and Roughness of Bearing Surface in Retrieved Polyethylene Bicon-Plus Cups].
    Ranuša M; Gallo J; Hobza M; Vrbka M; Nečas D; Hartl M
    Acta Chir Orthop Traumatol Cech; 2017; 84(3):159-167. PubMed ID: 28809634
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On the roughness measurement on knee prostheses.
    Jaber SA; Ruggiero A; Battaglia S; Affatato S
    Int J Artif Organs; 2015 Jan; 38(1):39-44. PubMed ID: 25588764
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differences in Trochlear Surface Damage and Wear Between Three Different Total Knee Arthroplasty Designs.
    Matz J; Howard JL; Sisko ZW; Teeter MG; Lanting BA
    J Arthroplasty; 2017 Dec; 32(12):3763-3770. PubMed ID: 28750858
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Posterior condyle surface damage on retrieved femoral knee components.
    Burnell CD; Brandt JM; Petrak MJ; Bourne RB
    J Arthroplasty; 2011 Dec; 26(8):1460-7. PubMed ID: 21570806
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Matched-pair total knee arthroplasty retrieval analysis: oxidized zirconium vs. CoCrMo.
    Heyse TJ; Chen DX; Kelly N; Boettner F; Wright TM; Haas SB
    Knee; 2011 Dec; 18(6):448-52. PubMed ID: 20869251
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement.
    Elfick AP; Hall RM; Pinder IM; Unsworth A
    J Biomed Mater Res; 1999; 48(5):712-8. PubMed ID: 10490687
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo roughening of retrieved total knee arthroplasty femoral components.
    Malikian R; Maruthainar K; Stammers J; Cannon SR; Carrington R; Skinner JA; Maruthainar N; Dowd G; Briggs TW; Blunn GW
    Knee; 2014 Jan; 21(1):278-82. PubMed ID: 23142273
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Iatrogenic surface damage during femoral component impaction in total knee arthroplasty.
    Vanlommel J; Porteous AJ; Hassaballa MA; Luyckx JP; Bellemans J
    Knee; 2010 Jan; 17(1):43-7. PubMed ID: 19666227
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement.
    Lancaster JG; Dowson D; Isaac GH; Fisher J
    Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions.
    Pourzal R; Hall DJ; Ehrich J; McCarthy SM; Mathew MT; Jacobs JJ; Urban RM
    Clin Orthop Relat Res; 2017 Dec; 475(12):3026-3043. PubMed ID: 28884275
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components.
    White SE; Whiteside LA; McCarthy DS; Anthony M; Poggie RA
    Clin Orthop Relat Res; 1994 Dec; (309):176-84. PubMed ID: 7994957
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.