BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 10501049)

  • 21. Monte Carlo calculation of dose rate distributions around 192Ir wires.
    Ballester F; Hernández C; Pérez-Calatayud J; Lliso F
    Med Phys; 1997 Aug; 24(8):1221-8. PubMed ID: 9284243
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
    Bannon EA; Yang Y; Rivard MJ
    Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Anisotropy functions for 103Pd, 125I, and 192Ir interstitial brachytherapy sources.
    Nath R; Meigooni AS; Muench P; Melillo A
    Med Phys; 1993; 20(5):1465-73. PubMed ID: 8289730
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.
    Ballester F; Puchades V; Lluch JL; Serrano-Andrés MA; Limami Y; Pérez-Calatayud J; Casal E
    Med Phys; 2001 Dec; 28(12):2586-91. PubMed ID: 11797964
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dosimetry parameters of the IRH10 192Ir high dose rate brachytherapy source.
    Yi CY; Chun KJ; Hah SH; Kim HM; Lim C
    J Radiat Res; 2010; 51(4):485-92. PubMed ID: 20508393
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Dosimetric modeling of the microselectron high-dose rate 192Ir source by the multigroup discrete ordinates method.
    Daskalov GM; Baker RS; Rogers DW; Williamson JF
    Med Phys; 2000 Oct; 27(10):2307-19. PubMed ID: 11099199
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Anisotropy function for 192Ir low-dose-rate brachytherapy sources: an EGS4 Monte Carlo study.
    Capote R; Mainegra E; López E
    Phys Med Biol; 2001 May; 46(5):1487-99. PubMed ID: 11384066
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
    Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
    Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Dosimetry characteristics of the Plus and 12i Gammamed PDR 192Ir sources.
    Pérez-Calatayud J; Ballester F; Serrano-Andrés MA; Puchades V; Lluch JL; Limami Y; Casal F
    Med Phys; 2001 Dec; 28(12):2576-85. PubMed ID: 11797963
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Dosimetric characteristics of the bests double-wall 103Pd brachytherapy source.
    Meigooni AS; Bharucha Z; Yoe-Sein M; Sowards K
    Med Phys; 2001 Dec; 28(12):2568-75. PubMed ID: 11797962
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source.
    Daskalov GM; Löffler E; Williamson JF
    Med Phys; 1998 Nov; 25(11):2200-8. PubMed ID: 9829246
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Dosimetry on transverse axes of 125I and 192Ir interstitial brachytherapy sources.
    Nath R; Meigooni AS; Meli JA
    Med Phys; 1990; 17(6):1032-40. PubMed ID: 2280732
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Monte Carlo calculations and experimental measurements of dosimetry parameters of a new 103Pd source.
    Li Z; Palta JR; Fan JJ
    Med Phys; 2000 May; 27(5):1108-12. PubMed ID: 10841416
    [TBL] [Abstract][Full Text] [Related]  

  • 34. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.
    Selvam TP; Sahoo S; Vishwakarma RS
    Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of dosimetric parameters for various 192Ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation.
    Devan K; Aruna P; Manigandan D; Bharanidharan G; Subbaiah KV; Sunny CS; Ganesan S
    Med Dosim; 2007; 32(4):305-15. PubMed ID: 17980833
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Beta versus gamma dosimetry close to Ir-192 brachytherapy sources.
    Baltas D; Karaiskos P; Papagiannis P; Sakelliou L; Loeffler E; Zamboglou N
    Med Phys; 2001 Sep; 28(9):1875-82. PubMed ID: 11585218
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism.
    Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L
    Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monte carlo investigation of the dosimetric properties of the new 103Pd BrachySeedPd-103 Model Pd-1 source.
    Chan GH; Prestwich WV
    Med Phys; 2002 Sep; 29(9):1984-90. PubMed ID: 12349919
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Dosimetry comparison of 192Ir sources.
    Papagiannis P; Angelopoulos A; Pantelis E; Sakelliou L; Baltas D; Karaiskos P; Sandilos P; Vlachos L
    Med Phys; 2002 Oct; 29(10):2239-46. PubMed ID: 12408297
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dose calculation in brachytherapy for a 192Ir source using a primary and scatter dose separation technique.
    Russell KR; Ahnesjö A
    Phys Med Biol; 1996 Jun; 41(6):1007-24. PubMed ID: 8794481
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.