These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
122 related articles for article (PubMed ID: 10502637)
1. Microbubbles and mitral valve prostheses - transesophageal echocardiographic evaluation. Levy DJ; Child JS; Rambod E; Gharib M; Milo S; Reisner SA Eur J Ultrasound; 1999 Sep; 10(1):31-40. PubMed ID: 10502637 [TBL] [Abstract][Full Text] [Related]
2. Prevalence of microbubbles associated with mechanical prosthetic cardiac valves: a prospective transesophageal echocardiography study. Gencbay M; Turan F; Yaymaci B; Degertekin M; Basaran Y; Dindar I; Izgi A J Heart Valve Dis; 1998 May; 7(3):340-4. PubMed ID: 9651850 [TBL] [Abstract][Full Text] [Related]
3. Comparison of transthoracic and transesophageal echocardiography in evaluation of 47 Starr-Edwards prosthetic valves. Alton ME; Pasierski TJ; Orsinelli DA; Eaton GM; Pearson AC J Am Coll Cardiol; 1992 Dec; 20(7):1503-11. PubMed ID: 1452923 [TBL] [Abstract][Full Text] [Related]
4. Microbubbles associated with mitral valve prostheses in pediatric patients. Levy D; Lawrenson J; Schulz J; Milo S; Reisner SA Eur J Ultrasound; 1999 Jul; 9(3):213-21. PubMed ID: 10657596 [TBL] [Abstract][Full Text] [Related]
5. [Late complications following Björk-Shiley and St. Jude Medical heart valve replacement]. Horstkotte D; Körfer R; Budde T; Haerten K; Schulte HD; Bircks W; Loogen F Z Kardiol; 1983 May; 72(5):251-61. PubMed ID: 6880335 [TBL] [Abstract][Full Text] [Related]
6. Comparative phonocardiographic, echocardiographic and Doppler echocardiographic evaluation of normally functioning Medtronic Hall and Björk-Shiley mitral prosthetic valves. Fukuda N; Oki T; Tabata T; Hosoi K; Iuchi A; Manabe K; Kageji Y; Sasaki M; Hama M; Ito S J Heart Valve Dis; 1994 May; 3(3):275-82. PubMed ID: 8087264 [TBL] [Abstract][Full Text] [Related]
7. Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study. Lindower PD; Dellsperger KC; Johnson B; Chandran KB; Vandenberg BF J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S178-83. PubMed ID: 8905518 [TBL] [Abstract][Full Text] [Related]
8. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses]. Minardi G; Di Segni M; Boccardi L; Ferrari O; Giovannini E G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201 [TBL] [Abstract][Full Text] [Related]
9. Regurgitant flow of mitral valve prostheses: an intraoperative transesophageal echocardiographic study. Meloni L; Aru G; Abbruzzese PA; Cardu G; Ricchi A; Cattolica FS; Martelli V; Cherchi A J Am Soc Echocardiogr; 1994; 7(1):36-46. PubMed ID: 8155332 [TBL] [Abstract][Full Text] [Related]
10. Microbubbles associated with mechanical heart valves: their relationwith serum lactic dehydrogenase levels. Gencbay M; Degertekin M; Basaran Y; Yaymaci B; Izgi A; Dindar I; Turan F Am Heart J; 1999 Mar; 137(3):463-8. PubMed ID: 10047627 [TBL] [Abstract][Full Text] [Related]
11. Normal and abnormal prosthetic valve function as assessed by Doppler echocardiography. Panidis IP; Ross J; Mintz GS J Am Coll Cardiol; 1986 Aug; 8(2):317-26. PubMed ID: 2942593 [TBL] [Abstract][Full Text] [Related]
12. Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic values. Sagar KB; Wann LS; Paulsen WH; Romhilt DW J Am Coll Cardiol; 1986 Mar; 7(3):681-7. PubMed ID: 3950245 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping. Dittrich H; Nicod P; Hoit B; Dalton N; Sahn D Am Heart J; 1988 Jan; 115(1 Pt 1):133-8. PubMed ID: 3336968 [TBL] [Abstract][Full Text] [Related]
14. Transcranial high-intensity Doppler signals in patients with mechanical heart valve prostheses: their relationship with abnormal intracavitary echoes. Deklunder G; Lecroart JL; Savoye C; Coquet B; Houdas Y J Heart Valve Dis; 1996 Nov; 5(6):662-7. PubMed ID: 8953445 [TBL] [Abstract][Full Text] [Related]
15. Spontaneously appearing microbubbles associated with prosthetic cardiac valves detected by transesophageal echocardiography. Orsinelli DA; Pasierski TJ; Pearson AC Am Heart J; 1994 Nov; 128(5):990-6. PubMed ID: 7942493 [TBL] [Abstract][Full Text] [Related]
16. A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves. Rambod E; Beizaie M; Shusser M; Milo S; Gharib M Ann Biomed Eng; 1999; 27(6):774-92. PubMed ID: 10625150 [TBL] [Abstract][Full Text] [Related]
17. Analysis of Doppler-obtained velocity curves in functional evaluation of mechanical prosthetic valves in the mitral and aortic positions. Goldrath N; Zimes R; Vered Z J Am Soc Echocardiogr; 1988; 1(3):211-25. PubMed ID: 3272769 [TBL] [Abstract][Full Text] [Related]
18. Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves. Williams GA; Labovitz AJ Am J Cardiol; 1985 Aug; 56(4):325-32. PubMed ID: 4025173 [TBL] [Abstract][Full Text] [Related]
19. [Transesophageal echocardiography assessment of regurgitant jets of eccentric geometry in mitral valve prosthesis: superiority of multiplanar sections over standard sections]. Sousa RC; Garcia-Fernandéz MA; Bobadilha JF; Moreno M; Garrido P; Torrecilla EG; Roman DS; Bermejo J; Delcán JL Rev Port Cardiol; 1994 Dec; 13(12):919-27, 892. PubMed ID: 7873222 [TBL] [Abstract][Full Text] [Related]
20. Usefulness of Mitral Valve Prosthetic or Bioprosthetic Time Velocity Index Ratio to Detect Prosthetic or Bioprosthetic Mitral Valve Dysfunction. Luis SA; Blauwet LA; Samardhi H; West C; Mehta RA; Luis CR; Scalia GM; Miller FA; Burstow DJ Am J Cardiol; 2017 Oct; 120(8):1373-1380. PubMed ID: 28826894 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]