BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 10502748)

  • 1. Venous blood effects in spin-echo fMRI of human brain.
    Oja JM; Gillen J; Kauppinen RA; Kraut M; van Zijl PC
    Magn Reson Med; 1999 Oct; 42(4):617-26. PubMed ID: 10502748
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microvascular BOLD contribution at 4 and 7 T in the human brain: gradient-echo and spin-echo fMRI with suppression of blood effects.
    Duong TQ; Yacoub E; Adriany G; Hu X; Ugurbil K; Kim SG
    Magn Reson Med; 2003 Jun; 49(6):1019-27. PubMed ID: 12768579
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diffusion-weighted spin-echo fMRI at 9.4 T: microvascular/tissue contribution to BOLD signal changes.
    Lee SP; Silva AC; Ugurbil K; Kim SG
    Magn Reson Med; 1999 Nov; 42(5):919-28. PubMed ID: 10542351
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cortical depth-dependent gradient-echo and spin-echo BOLD fMRI at 9.4T.
    Zhao F; Wang P; Kim SG
    Magn Reson Med; 2004 Mar; 51(3):518-24. PubMed ID: 15004793
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla.
    Parkes LM; Schwarzbach JV; Bouts AA; Deckers RH; Pullens P; Kerskens CM; Norris DG
    Magn Reson Med; 2005 Dec; 54(6):1465-72. PubMed ID: 16276507
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sources of functional apparent diffusion coefficient changes investigated by diffusion-weighted spin-echo fMRI.
    Jin T; Zhao F; Kim SG
    Magn Reson Med; 2006 Dec; 56(6):1283-92. PubMed ID: 17051530
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Component structure of event-related fMRI responses in the different neurovascular compartments.
    Roberts KC; Tran TT; Song AW; Woldorff MG
    Magn Reson Imaging; 2007 Apr; 25(3):328-34. PubMed ID: 17371721
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the numerically predicted spatial BOLD fMRI specificity for spin echo sequences.
    Pflugfelder D; Vahedipour K; Uludağ K; Shah NJ; Stöcker T
    Magn Reson Imaging; 2011 Nov; 29(9):1195-204. PubMed ID: 21917392
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla.
    Thulborn KR; Chang SY; Shen GX; Voyvodic JT
    NMR Biomed; 1997; 10(4-5):183-90. PubMed ID: 9430346
    [TBL] [Abstract][Full Text] [Related]  

  • 10. BOLD specificity and dynamics evaluated in humans at 7 T: comparing gradient-echo and spin-echo hemodynamic responses.
    Siero JC; Ramsey NF; Hoogduin H; Klomp DW; Luijten PR; Petridou N
    PLoS One; 2013; 8(1):e54560. PubMed ID: 23336008
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurements of tissue T1 spin-lattice relaxation time and discrimination of large draining veins using transient EPI data sets in BOLD-weighted fMRI acquisitions.
    Mazaheri Y; Biswal BB; Ward BD; Hyde JS
    Neuroimage; 2006 Aug; 32(2):603-15. PubMed ID: 16713305
    [TBL] [Abstract][Full Text] [Related]  

  • 12. T1rho contrast in functional magnetic resonance imaging.
    Hulvershorn J; Borthakur A; Bloy L; Gualtieri EE; Reddy R; Leigh JS; Elliott MA
    Magn Reson Med; 2005 Nov; 54(5):1155-62. PubMed ID: 16217783
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of large veins on spatial localization with GE BOLD at 3 T: Displacement, not blurring.
    Olman CA; Inati S; Heeger DJ
    Neuroimage; 2007 Feb; 34(3):1126-35. PubMed ID: 17157534
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: insights into hemodynamic regulation.
    Zhao F; Wang P; Hendrich K; Ugurbil K; Kim SG
    Neuroimage; 2006 May; 30(4):1149-60. PubMed ID: 16414284
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sensitivity of BOLD response to increasing visual contrast: spin echo versus gradient echo EPI.
    Chiacchiaretta P; Romani GL; Ferretti A
    Neuroimage; 2013 Nov; 82():35-43. PubMed ID: 23707589
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental determination of the BOLD field strength dependence in vessels and tissue.
    Gati JS; Menon RS; Ugurbil K; Rutt BK
    Magn Reson Med; 1997 Aug; 38(2):296-302. PubMed ID: 9256111
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved spatial localization of post-stimulus BOLD undershoot relative to positive BOLD.
    Zhao F; Jin T; Wang P; Kim SG
    Neuroimage; 2007 Feb; 34(3):1084-92. PubMed ID: 17161623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative differentiation between BOLD models in fMRI.
    Hoogenraad FG; Pouwels PJ; Hofman MB; Reichenbach JR; Sprenger M; Haacke EM
    Magn Reson Med; 2001 Feb; 45(2):233-46. PubMed ID: 11180431
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Segmented spin-echo pulses to increase fMRI signal: repeated intrinsic diffusional enhancement.
    Song AW; Mao H; Muthupillai R; Haist F; Dixon WT
    Magn Reson Med; 1999 Oct; 42(4):631-5. PubMed ID: 10502750
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spatial sensitivity and temporal response of spin echo and gradient echo bold contrast at 3 T using peak hemodynamic activation time.
    Hulvershorn J; Bloy L; Gualtieri EE; Leigh JS; Elliott MA
    Neuroimage; 2005 Jan; 24(1):216-23. PubMed ID: 15588613
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.