These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
24. Cavitation damage of pyrolytic carbon in mechanical heart valves. Kafesjian R; Howanec M; Ward GD; Diep L; Wagstaff LS; Rhee R J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S2-7. PubMed ID: 8061867 [TBL] [Abstract][Full Text] [Related]
25. Cavitation phenomenon in monoleaflet mechanical heart valves with electrohydraulic total artificial heart. Lee H; Taenaka Y; Kitamura S Int J Artif Organs; 2004 Sep; 27(9):779-86. PubMed ID: 15521218 [TBL] [Abstract][Full Text] [Related]
26. Cavitation potential of mechanical heart valve prostheses. Graf T; Fischer H; Reul H; Rau G Int J Artif Organs; 1991 Mar; 14(3):169-74. PubMed ID: 2045192 [TBL] [Abstract][Full Text] [Related]
27. Cavitation behavior observed in three monoleaflet mechanical heart valves under accelerated testing conditions. Lo CW; Liu JS; Li CP; Lu PC; Hwang NH ASAIO J; 2008; 54(2):163-71. PubMed ID: 18356649 [TBL] [Abstract][Full Text] [Related]
28. A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis. Bluestein D; Einav S; Hwang NH J Biomech; 1994 Nov; 27(11):1369-78. PubMed ID: 7798287 [TBL] [Abstract][Full Text] [Related]
29. Observation of cavitation in a mechanical heart valve in a total artificial heart. Lee H; Tsukiya T; Homma A; Kamimura T; Takewa Y; Nishinaka T; Tatsumi E; Taenaka Y; Takano H; Kitamura S ASAIO J; 2004; 50(3):205-10. PubMed ID: 15171470 [TBL] [Abstract][Full Text] [Related]
30. Effect of structural compliance on cavitation threshold measurement of mechanical heart valves. Guo GX; Adlparvar P; Howanec M; Roy J; Kafesjian R; Kingsbury C J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S77-83; discussion S83-4. PubMed ID: 8061872 [TBL] [Abstract][Full Text] [Related]
31. Causes and formation of cavitation in mechanical heart valves. Graf T; Reul H; Detlefs C; Wilmes R; Rau G J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S49-64. PubMed ID: 8061870 [TBL] [Abstract][Full Text] [Related]
34. A detailed fluid mechanics study of tilting disk mechanical heart valve closure and the implications to blood damage. Manning KB; Herbertson LH; Fontaine AA; Deutsch S J Biomech Eng; 2008 Aug; 130(4):041001. PubMed ID: 18601443 [TBL] [Abstract][Full Text] [Related]
35. Preclinical assessment of a trileaflet mechanical valve in the mitral position in a calf model. Gregoric I; Conger JL; Reul H; Tamez D; Clubb FJ; Stainback RF; Hernandez A; Cervera R; Eya K; Byler D; Kadipasaoglu KA; Frazier OH Ann Thorac Surg; 2004 Jan; 77(1):196-202. PubMed ID: 14726061 [TBL] [Abstract][Full Text] [Related]
36. Effect of cavitation on pyrolytic carbon in vitro. Haubold AD; Ely JL; Chahine GL J Heart Valve Dis; 1994 May; 3(3):318-23. PubMed ID: 8087272 [TBL] [Abstract][Full Text] [Related]
37. A method for real-time in vitro observation of cavitation on prosthetic heart valves. Zapanta CM; Liszka EG; Lamson TC; Stinebring DR; Deutsch S; Geselowitz DB; Tarbell JM J Biomech Eng; 1994 Nov; 116(4):460-8. PubMed ID: 7869722 [TBL] [Abstract][Full Text] [Related]
38. An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound. Makhijani VB; Yang HQ; Singhal AK; Hwang NH J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S35-44; discussion S44-8. PubMed ID: 8061869 [TBL] [Abstract][Full Text] [Related]
39. The effect of tip angle on cavitation potential during closure of a bileaflet prosthesis model. Zhang P; Yeo JH; Qian P; Hwang NH J Heart Valve Dis; 2007 Jul; 16(4):430-9. PubMed ID: 17702370 [TBL] [Abstract][Full Text] [Related]
40. Can cavitation bubbles generated by mechanical heart valves be detected by transcranial Doppler? Shu MC; Gross JM; Johnson KM J Heart Valve Dis; 1995 Sep; 4(5):542-52; discussion 552. PubMed ID: 8581199 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]