BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 10520390)

  • 1. Bacterial contamination of propofol in the operating theatre.
    Soong WA
    Anaesth Intensive Care; 1999 Oct; 27(5):493-6. PubMed ID: 10520390
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Routine handling of propofol prevents contamination as effectively as does strict adherence to the manufacturer's recommendations.
    Lorenz IH; Kolbitsch C; Lass-Flörl C; Gritznig I; Vollert B; Lingnau W; Moser PL; Benzer A
    Can J Anaesth; 2002 Apr; 49(4):347-52. PubMed ID: 11927472
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bacterial contamination of propofol: the effects of temperature and lidocaine.
    Aydin N; Aydin N; Gultekin B; Ozgun S; Gurel A
    Eur J Anaesthesiol; 2002 Jun; 19(6):455-8. PubMed ID: 12094922
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multiple withdrawals from single-use vials: a study on sterility.
    Ripoll Gallardo A; Meneghetti G; Ragazzoni L; Kroumova V; Ferrante D; Ingrassia PL; Ruzza P; Dell'Era A; Boniolo E; Koraqe G; Faggiano F; Della Corte F
    Int J Pharm; 2015 May; 485(1-2):160-3. PubMed ID: 25769293
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microbial stability of syringes of anesthetic drugs prepared in the operating room.
    Segal S; Gunawan A; McLaughlin DH; Palavecino E
    J Clin Anesth; 2019 Aug; 55():20-23. PubMed ID: 30586662
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bacterial contamination of propofol vials used in operating rooms of a third-level hospital.
    Zorrilla-Vaca A; Escandón-Vargas K; Brand-Giraldo V; León T; Herrera M; Payán A
    Am J Infect Control; 2016 Jan; 44(1):e1-3. PubMed ID: 26416525
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Infectious complications linked to the use of Diprivan. Precaution of administration].
    Veber B
    Ann Fr Anesth Reanim; 1994; 13(4):457-9. PubMed ID: 7872522
    [TBL] [Abstract][Full Text] [Related]  

  • 8. What are we injecting with our drugs?
    Merry AF; Gargiulo DA; Fry LE
    Anaesth Intensive Care; 2017 Sep; 45(5):539-542. PubMed ID: 28911282
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A microbiological study of the contamination of the syringes used in anaesthesia practice.
    Lessard MR; Trépanier CA; Gourdeau M; Denault PH
    Can J Anaesth; 1988 Nov; 35(6):567-9. PubMed ID: 3203452
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anaesthetic drugs and bacterial contamination.
    Magee L; Godsiff L; Matthews I; Farrington M; Park GR
    Eur J Anaesthesiol Suppl; 1995 Nov; 12():41-3. PubMed ID: 8719669
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Infection risk through the reuse of "used" cylinder ampoules for dental local anaesthesia (author's transl)].
    Gräf W
    Zentralbl Bakteriol Mikrobiol Hyg B; 1981; 174(1-2):1-14. PubMed ID: 7324616
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safety concerns with glass particle contamination: improving the standard guidelines for preparing medication injections.
    Chiannilkulchai N; Kejkornkaew S
    Int J Qual Health Care; 2021 Jun; 33(2):. PubMed ID: 34101800
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bacterial contamination in solution aspirated from non-sterile packaged fentanyl ampoules: a laboratory study.
    Merriman S; Paech MJ; Keil AD
    Anaesth Intensive Care; 2009 Jul; 37(4):608-12. PubMed ID: 19681420
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Propofol emulsion and bacterial contamination.
    McHugh GJ; Roper GM
    Can J Anaesth; 1995 Sep; 42(9):801-4. PubMed ID: 7497562
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Do infusions of midazolam and propofol pose an infection risk to critically ill patients?
    Farrington M; McGinnes J; Matthews I; Park GR
    Br J Anaesth; 1994 Apr; 72(4):415-7. PubMed ID: 8155442
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Drug contamination from opening glass ampules.
    Zacher AN; Zornow MH; Evans G
    Anesthesiology; 1991 Nov; 75(5):893-5. PubMed ID: 1952213
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Glass contamination in parenterally administered medication.
    Preston ST; Hegadoren K
    J Adv Nurs; 2004 Nov; 48(3):266-70. PubMed ID: 15488040
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Study on insoluble microparticulate contamination at ampoule opening].
    Kawasaki Y
    Yakugaku Zasshi; 2009 Sep; 129(9):1041-7. PubMed ID: 19721379
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Particulate and microbial contamination in in-use admixed intravenous infusions.
    Yorioka K; Oie S; Oomaki M; Imamura A; Kamiya A
    Biol Pharm Bull; 2006 Nov; 29(11):2321-3. PubMed ID: 17077539
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two serial check valves can prevent cross-contamination through intravenous tubing during total intravenous anesthesia.
    Radke OC; Werth K; Borg-von-Zepelin M; Saur P; Apfel CC
    Anesth Analg; 2010 Oct; 111(4):925-8. PubMed ID: 20810677
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.