172 related articles for article (PubMed ID: 10522588)
1. Catheter entrapment by atrial suture during minimally invasive port-access cardiac surgery.
Deneu S; Coddens J; Deloof T
Can J Anaesth; 1999 Oct; 46(10):983-6. PubMed ID: 10522588
[TBL] [Abstract][Full Text] [Related]
2. Entrapment of pulmonary artery catheter in a suture at the inferior vena cava cannulation site.
Huang L; Elsharydah A; Nawabi A; Cork RC
J Clin Anesth; 2004 Nov; 16(7):557-9. PubMed ID: 15590265
[TBL] [Abstract][Full Text] [Related]
3. [Minimally invasive surgery with the Port-Access method. Preliminary experience].
Viganò M; Minzioni G; Spreafico P; Pasquino S; Ceriana P; Locatelli A; Maurelli M
G Ital Cardiol; 1998 Nov; 28(11):1225-9. PubMed ID: 9866799
[TBL] [Abstract][Full Text] [Related]
4. The endovascular coronary sinus catheter in minimally invasive mitral and tricuspid valve surgery: a case series.
Lebon JS; Couture P; Rochon AG; Laliberté E; Harvey J; Aubé N; Cossette M; Bouchard D; Jeanmart H; Pellerin M
J Cardiothorac Vasc Anesth; 2010 Oct; 24(5):746-51. PubMed ID: 20638867
[TBL] [Abstract][Full Text] [Related]
5. Transesophageal echocardiography or fluoroscopy during port-access surgery?
Mierdl S; Meininger D; Byhahn C; Aybek T; Kessler P; Westphal K
Ann Acad Med Singap; 2002 Jul; 31(4):520-4. PubMed ID: 12161891
[TBL] [Abstract][Full Text] [Related]
6. Perfusion during coronary and mitral valve surgery utilizing minimally invasive Port-Access technology.
Toomasian JM; Williams DL; Colvin SB; Reitz BA
J Extra Corpor Technol; 1997 Jun; 29(2):66-72. PubMed ID: 10173052
[TBL] [Abstract][Full Text] [Related]
7. Continuous transesophageal echocardiographic (TEE) monitoring during port-access cardiac surgery.
Schulze CJ; Wildhirt SM; Boehm DH; Weigand C; Kornberg A; Reichenspurner H; Reichart B
Heart Surg Forum; 1999; 2(1):54-9. PubMed ID: 11276461
[TBL] [Abstract][Full Text] [Related]
8. Utility of transesophageal echocardiography during port-access minimally invasive cardiac surgery.
Applebaum RM; Cutler WM; Bhardwaj N; Colvin SB; Galloway AC; Ribakove GH; Grossi EA; Schwartz DS; Anderson RV; Tunick PA; Kronzon I
Am J Cardiol; 1998 Jul; 82(2):183-8. PubMed ID: 9678289
[TBL] [Abstract][Full Text] [Related]
9. Video and robotic-assisted minimally invasive mitral valve surgery: a comparison of the Port-Access and transthoracic clamp techniques.
Reichenspurner H; Detter C; Deuse T; Boehm DH; Treede H; Reichart B
Ann Thorac Surg; 2005 Feb; 79(2):485-90; discussion 490-1. PubMed ID: 15680820
[TBL] [Abstract][Full Text] [Related]
10. The Swan-Ganz catheter as a teaching tool for the anesthesiologist learning minimally invasive cardiac surgery.
Pantin EJ; Kraidin JL; Ginsberg SH; Denny JT; Anderson MB; Solina AR
Innovations (Phila); 2012; 7(3):204-7. PubMed ID: 22885463
[TBL] [Abstract][Full Text] [Related]
11. Extracorporeal circulation for port-access cardiac surgery.
Toomasian JM; Peters WS; Siegel LC; Stevens JH
Perfusion; 1997 Mar; 12(2):83-91. PubMed ID: 9160358
[TBL] [Abstract][Full Text] [Related]
12. Port-access mitral valve replacement in dogs.
Pompili MF; Stevens JH; Burdon TA; Siegel LC; Peters WS; Ribakove GH; Reitz BA
J Thorac Cardiovasc Surg; 1996 Nov; 112(5):1268-74. PubMed ID: 8911323
[TBL] [Abstract][Full Text] [Related]
13. [Entrapment of a Swan-Ganz catheter within the right pulmonary artery ligature during right pneumonectomy].
Heves Karagöz A; Kanbak M; Celebioğlu B; Akinci SB; Kara M; Doğan R
Tuberk Toraks; 2009; 57(1):81-3. PubMed ID: 19533443
[TBL] [Abstract][Full Text] [Related]
14. Severe Tricuspid Regurgitation After Percutaneous Removal of a Swan-Ganz Catheter Caught by Suture.
Gennari M; Bartorelli AL; Polvani G; Muratori M; Ferrari C; Penza E; Arlati FG; Agrifoglio M
Ann Thorac Surg; 2017 Sep; 104(3):e225-e226. PubMed ID: 28838512
[TBL] [Abstract][Full Text] [Related]
15. [Suture of pulmonary artery catheter in heart surgery].
Encinar-Arias L; Rodríguez-Rodríguez A
Rev Esp Anestesiol Reanim; 1996 May; 43(5):187. PubMed ID: 8927784
[No Abstract] [Full Text] [Related]
16. Transoesophageal echocardiography: a useful tool to diagnose entrapment of pulmonary artery catheter.
Rupert E; Paul A; Mukherji J
Anaesthesia; 2006 Jul; 61(7):702-4. PubMed ID: 16792618
[TBL] [Abstract][Full Text] [Related]
17. Snaring of a Swan-Ganz catheter.
Block PC
J Thorac Cardiovasc Surg; 1976 Jun; 71(6):917-9. PubMed ID: 775200
[TBL] [Abstract][Full Text] [Related]
18. Transesophageal echocardiographic diagnosis of intracardiac entrapment of a Swan-Ganz catheter in open heart operation.
Wang HJ; Wang SS; Liau CS
J Am Soc Echocardiogr; 2004 Mar; 17(3):277-9. PubMed ID: 14981428
[TBL] [Abstract][Full Text] [Related]
19. Minimally invasive port access versus conventional mitral valve surgery: prospective randomized study.
Dogan S; Aybek T; Risteski PS; Detho F; Rapp A; Wimmer-Greinecker G; Moritz A
Ann Thorac Surg; 2005 Feb; 79(2):492-8. PubMed ID: 15680822
[TBL] [Abstract][Full Text] [Related]
20. Minimally Invasive Port Access Approach for Reoperations on the Mitral Valve.
Vallabhajosyula P; Wallen T; Pulsipher A; Pitkin E; Solometo LP; Musthaq S; Fox J; Acker M; Hargrove WC
Ann Thorac Surg; 2015 Jul; 100(1):68-73. PubMed ID: 25975939
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]