These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 10524291)

  • 1. Characterization and application of thin film pressure sensors.
    Valdevit A; Ortega-Garcia J; Kambic H; Kuroda R; Elster T; Parker RD
    Biomed Mater Eng; 1999; 9(2):81-8. PubMed ID: 10524291
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new technique to measure the dynamic contact pressures on the Tibial Plateau.
    Cottrell JM; Scholten P; Wanich T; Warren RF; Wright TM; Maher SA
    J Biomech; 2008 Jul; 41(10):2324-9. PubMed ID: 18539286
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The level of compressive load affects conclusions from statistical analyses to determine whether a lateral meniscal autograft restores tibial contact pressure to normal: a study in human cadaveric knees.
    Huang A; Hull ML; Howell SM
    J Orthop Res; 2003 May; 21(3):459-64. PubMed ID: 12706018
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of dynamic posterior stabilization on facet joint contact forces: an in vitro investigation.
    Niosi CA; Wilson DC; Zhu Q; Keynan O; Wilson DR; Oxland TR
    Spine (Phila Pa 1976); 2008 Jan; 33(1):19-26. PubMed ID: 18165744
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee.
    Lee SJ; Aadalen KJ; Malaviya P; Lorenz EP; Hayden JK; Farr J; Kang RW; Cole BJ
    Am J Sports Med; 2006 Aug; 34(8):1334-44. PubMed ID: 16636354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An implantable telemetry device to measure intra-articular tibial forces.
    D'Lima DD; Townsend CP; Arms SW; Morris BA; Colwell CW
    J Biomech; 2005 Feb; 38(2):299-304. PubMed ID: 15598457
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Varying femoral tunnels between the anatomical footprint and isometric positions: effect on kinematics of the anterior cruciate ligament-reconstructed knee.
    Musahl V; Plakseychuk A; VanScyoc A; Sasaki T; Debski RE; McMahon PJ; Fu FH
    Am J Sports Med; 2005 May; 33(5):712-8. PubMed ID: 15722268
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prosthetic replacement of the medial meniscus in cadaveric knees: does the prosthesis mimic the functional behavior of the native meniscus?
    Tienen TG; Verdonschot N; Heijkants RG; Buma P; Scholten JG; van Kampen A; Veth RP
    Am J Sports Med; 2004; 32(5):1182-8. PubMed ID: 15262640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau: an experimental study in human cadaveric knee joints.
    Dienst M; Greis PE; Ellis BJ; Bachus KN; Burks RT
    Am J Sports Med; 2007 Jan; 35(1):34-42. PubMed ID: 16923825
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of tibiofemoral joint kinematics on patellofemoral contact pressures under simulated muscle loads.
    Li G; DeFrate LE; Zayontz S; Park SE; Gill TJ
    J Orthop Res; 2004 Jul; 22(4):801-6. PubMed ID: 15183437
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of applied quadriceps and hamstrings muscle loads on forces in the anterior and posterior cruciate ligaments.
    Markolf KL; O'Neill G; Jackson SR; McAllister DR
    Am J Sports Med; 2004; 32(5):1144-9. PubMed ID: 15262635
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In situ forces in the human posterior cruciate ligament in response to muscle loads: a cadaveric study.
    Höher J; Vogrin TM; Woo SL; Carlin GJ; Arøen A; Harner CD
    J Orthop Res; 1999 Sep; 17(5):763-8. PubMed ID: 10569489
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Osteochondral defects in the human knee: influence of defect size on cartilage rim stress and load redistribution to surrounding cartilage.
    Guettler JH; Demetropoulos CK; Yang KH; Jurist KA
    Am J Sports Med; 2004 Sep; 32(6):1451-8. PubMed ID: 15310570
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tibiofemoral contact stress after total knee arthroplasty: comparison of fixed and mobile-bearing inlay designs.
    Stukenborg-Colsman C; Ostermeier S; Hurschler C; Wirth CJ
    Acta Orthop Scand; 2002 Dec; 73(6):638-46. PubMed ID: 12553510
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of calibration method on Tekscan sensor accuracy.
    Brimacombe JM; Wilson DR; Hodgson AJ; Ho KC; Anglin C
    J Biomech Eng; 2009 Mar; 131(3):034503. PubMed ID: 19154074
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relative positions of the contacts on the cartilage surfaces of the knee joint.
    Walker PS; Yildirim G; Sussman-Fort J; Klein GR
    Knee; 2006 Oct; 13(5):382-8. PubMed ID: 16790353
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tibiofemoral contact mechanics with a femoral resurfacing prosthesis and a non-functional meniscus.
    Becher C; Huber R; Thermann H; Tibesku CO; von Skrbensky G
    Clin Biomech (Bristol, Avon); 2009 Oct; 24(8):648-54. PubMed ID: 19560241
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Contact stresses in the knee joint in deep flexion.
    Thambyah A; Goh JC; De SD
    Med Eng Phys; 2005 May; 27(4):329-35. PubMed ID: 15823474
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Force measurements on the posterior oblique ligament and superficial medial collateral ligament proximal and distal divisions to applied loads.
    Griffith CJ; Wijdicks CA; LaPrade RF; Armitage BM; Johansen S; Engebretsen L
    Am J Sports Med; 2009 Jan; 37(1):140-8. PubMed ID: 18725650
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intra-articular load distribution in the human ankle joint during motion.
    Michelson JD; Checcone M; Kuhn T; Varner K
    Foot Ankle Int; 2001 Mar; 22(3):226-33. PubMed ID: 11310865
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.