These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 10531740)

  • 1. Measuring abutment/implant joint integrity with the Periotest instrument.
    Faulkner MG; Wolfaardt JF; Chan A
    Int J Oral Maxillofac Implants; 1999; 14(5):681-8. PubMed ID: 10531740
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implant-abutment screw joint preload of 7 hex-top abutment systems.
    Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2001; 16(3):367-77. PubMed ID: 11432656
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
    Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
    J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.
    Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D
    J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Implant abutment screw rotations and preloads for four different screw materials and surfaces.
    Martin WC; Woody RD; Miller BH; Miller AW
    J Prosthet Dent; 2001 Jul; 86(1):24-32. PubMed ID: 11458261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Relationship between implant preload and screw loosening on implant-supported prostheses.
    Siamos G; Winkler S; Boberick KG
    J Oral Implantol; 2002; 28(2):67-73. PubMed ID: 12498448
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use and abuse of the Periotest for 2-piece implant/abutment systems.
    Faulkner MG; Giannitsios D; Lipsett AW; Wolfaardt JF
    Int J Oral Maxillofac Implants; 2001; 16(4):486-94. PubMed ID: 11515995
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Probabilistic analysis of preload in the abutment screw of a dental implant complex.
    Guda T; Ross TA; Lang LA; Millwater HR
    J Prosthet Dent; 2008 Sep; 100(3):183-93. PubMed ID: 18762030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device.
    Lee J; Kim YS; Kim CW; Han JS
    J Prosthet Dent; 2002 Oct; 88(4):402-8. PubMed ID: 12447217
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An improved impact technique for monitoring percutaneous implant integrity.
    Swain R; Faulkner G; Raboud D; Wolfaardt J
    Int J Oral Maxillofac Implants; 2008; 23(2):263-9. PubMed ID: 18548922
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Resistance of ITI implant connectors to multivectorial fatigue load application.
    Wiskott HW; Pavone AF; Scherrer SS; Renevey RR; Belser UC
    Int J Prosthodont; 2004; 17(6):672-9. PubMed ID: 15686095
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability.
    Meredith N; Friberg B; Sennerby L; Aparicio C
    Int J Prosthodont; 1998; 11(3):269-75. PubMed ID: 9728122
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the ITI Morse taper implant/abutment design with an internal modification.
    Ding TA; Woody RD; Higginbottom FL; Miller BH
    Int J Oral Maxillofac Implants; 2003; 18(6):865-72. PubMed ID: 14696662
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Micromotion and dynamic fatigue properties of the dental implant-abutment interface.
    Gratton DG; Aquilino SA; Stanford CM
    J Prosthet Dent; 2001 Jan; 85(1):47-52. PubMed ID: 11174678
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of screw retention of nine abutment systems: a pilot study.
    Schulte JK; Coffey J
    Implant Dent; 1997; 6(1):28-31. PubMed ID: 9206402
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of eliminating implant/abutment rotational misfit on screw joint stability.
    Binon PP; McHugh MJ
    Int J Prosthodont; 1996; 9(6):511-9. PubMed ID: 9171488
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preload loss in gold prosthesis-retaining screws as a function of time.
    Cantwell A; Hobkirk JA
    Int J Oral Maxillofac Implants; 2004; 19(1):124-32. PubMed ID: 14982365
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An in vitro analysis of implant screw torque loss with external hex and internal connection implant systems.
    Piermatti J; Yousef H; Luke A; Mahevich R; Weiner S
    Implant Dent; 2006 Dec; 15(4):427-35. PubMed ID: 17172962
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing.
    Al Jabbari YS; Fournelle R; Ziebert G; Toth J; Iacopino AM
    J Prosthodont; 2008 Apr; 17(3):192-200. PubMed ID: 18205737
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.