BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 10536547)

  • 1. Direct measurement of mucosal pressures exerted by cuff and non-cuff portions of tracheal tubes with different cuff volumes and head and neck positions.
    Brimacombe J; Keller C; Giampalmo M; Sparr HJ; Berry A
    Br J Anaesth; 1999 May; 82(5):708-11. PubMed ID: 10536547
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of cuff volume and anatomic location on pharyngeal, esophageal, and tracheal mucosal pressures with the esophageal tracheal combitube.
    Keller C; Brimacombe J; Boehler M; Loeckinger A; Puehringer F
    Anesthesiology; 2002 May; 96(5):1074-7. PubMed ID: 11981145
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calculated vs measured pharyngeal mucosal pressures with the laryngeal mask airway during cuff inflation: assessment of four locations.
    Keller C; Brimacombe J; Benzer A
    Br J Anaesth; 1999 Mar; 82(3):399-401. PubMed ID: 10434824
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Large cuff volumes impede posterior pharyngeal mucosal perfusion with the laryngeal tube airway.
    Brimacombe J; Keller C; Roth W; Loeckinger A
    Can J Anaesth; 2002 Dec; 49(10):1084-7. PubMed ID: 12477684
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The tracheal tube with a high-volume, low-pressure cuff at various airway inflation pressures.
    Inada T; Uesugi F; Kawachi S; Inada K
    Eur J Anaesthesiol; 1998 Nov; 15(6):629-32. PubMed ID: 9884846
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mucosal pressure and oropharyngeal leak pressure with the ProSeal versus laryngeal mask airway in anaesthetized paralysed patients.
    Keller C; Brimacombe J
    Br J Anaesth; 2000 Aug; 85(2):262-6. PubMed ID: 10992836
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of Head and Neck Position on Nasotracheal Tube Intracuff Pressure: A Prospective Observational Study.
    Kim HJ; Jang J; Kim SY; Park WK; Kim HJ
    J Clin Med; 2021 Aug; 10(17):. PubMed ID: 34501354
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In cadavers, directly measured mucosal pressures are similar for the Unique and the Soft Seal laryngeal mask airway devices.
    Keller C; Brimacombe J; Moriggl B; Lirk P; von Goedecke A
    Can J Anaesth; 2004 Oct; 51(8):834-7. PubMed ID: 15470175
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The changes of endotracheal tube intracuff pressures after ear and head and neck surgery-related positions: a prospective observational study.
    Kara H; Hundur D; Doruk C; Buyuk D; Cansever G; Salviz EA; Camci E
    Braz J Otorhinolaryngol; 2022; 88(1):46-52. PubMed ID: 32571751
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The TaperGuard™ endotracheal tube intracuff pressure increase is less than that of the Hi-Lo™ tube during nitrous oxide exposure: a model trachea study.
    Tsuboi S; Miyashita T; Yamaguchi Y; Yamamoto Y; Sakamaki K; Goto T
    Anesth Analg; 2013 Mar; 116(3):609-12. PubMed ID: 23400983
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The relationship between head and neck position and endotracheal tube intracuff pressure in the pediatric population.
    Kako H; Krishna SG; Ramesh AS; Merz MN; Elmaraghy C; Grischkan J; Jatana KR; Ruda J; Tobias JD
    Paediatr Anaesth; 2014 Mar; 24(3):316-21. PubMed ID: 24238105
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of pharyngeal mucosal pressure and airway sealing pressure with the laryngeal mask airway in anesthetized adult patients.
    Brimacombe J; Keller C
    Anesth Analg; 1998 Dec; 87(6):1379-82. PubMed ID: 9842832
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Effects of changes in head and neck position on a tracheal tube cuff].
    Inoue S; Takauchi Y; Kuro M; Ninaga H
    Masui; 1998 Sep; 47(9):1069-72. PubMed ID: 9785780
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pressures exerted by endobronchial devices.
    Roscoe A; Kanellakos GW; McRae K; Slinger P
    Anesth Analg; 2007 Mar; 104(3):655-8. PubMed ID: 17312225
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pressures on endotracheal tube cuffs.
    Black AM; Seegobin RD
    Anaesthesia; 1981 May; 36(5):498-511. PubMed ID: 7258585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs.
    Chenelle CT; Itagaki T; Fisher DF; Berra L; Kacmarek RM
    Respir Care; 2017 Jan; 62(1):102-112. PubMed ID: 27879379
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intracuff pressures in endotracheal and tracheostomy tubes. Related cuff physical characteristics.
    Bernhard WN; Yost L; Joynes D; Cothalis S; Turndorf H
    Chest; 1985 Jun; 87(6):720-5. PubMed ID: 3996057
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pharyngeal mucosal pressure and perfusion: a fiberoptic evaluation of the posterior pharynx in anesthetized adult patients with a modified cuffed oropharyngeal airway.
    Brimacombe J; Keller C; Pühringer F
    Anesthesiology; 1999 Dec; 91(6):1661-5. PubMed ID: 10598608
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of endotracheal tube cuff pressures using estimation techniques and direct intracuff measurement.
    Stewart SL; Secrest JA; Norwood BR; Zachary R
    AANA J; 2003 Dec; 71(6):443-7. PubMed ID: 15098531
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of head position on the cuff and tube tip position of preformed oral tracheal tubes in young children.
    Jordi Ritz EM; Von Ungern-Sternberg BS; Keller K; Frei FJ; Erb TO
    Anaesthesia; 2008 Jun; 63(6):604-9. PubMed ID: 18477271
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.