These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 10537263)

  • 1. Ultra-high-molecular weight polyethylene wear: an in vitro comparison of acetabular metal types and polished surfaces.
    Shepard MF; Lieberman JR; Kabo JM
    J Arthroplasty; 1999 Oct; 14(7):860-6. PubMed ID: 10537263
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. A prospective, randomised study.
    Kim YH; Kim JS; Cho SH
    J Bone Joint Surg Br; 2001 Jul; 83(5):742-50. PubMed ID: 11482320
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Backside wear in acetabular hip joint replacement.
    Braun S; Sonntag R; Schroeder S; Mueller U; Jaeger S; Gotterbarm T; Kretzer JP
    Acta Biomater; 2019 Jan; 83():467-476. PubMed ID: 30408561
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups.
    Barbour PS; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2000; 214(6):569-76. PubMed ID: 11201404
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Backside volumetric change in the polyethylene of uncemented acetabular components.
    Krieg AH; Speth BM; Ochsner PE
    J Bone Joint Surg Br; 2009 Aug; 91(8):1037-43. PubMed ID: 19651830
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator.
    Smith SL; Unsworth A
    Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The role of acetabular component screw holes and/or screws in the development of pelvic osteolysis.
    Schmalzried TP; Brown IC; Amstutz HC; Engh CA; Harris WH
    Proc Inst Mech Eng H; 1999; 213(2):147-53. PubMed ID: 10333686
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Five million wear simulation and particle analysis of carbon-based nano-multilayer coatings titanium alloy femoral head].
    Wang HR; Li J; Li ZL; Tu JP; Jin G; Su J; Wang JJ
    Zhonghua Yi Xue Za Zhi; 2020 Feb; 100(7):546-551. PubMed ID: 32164109
    [No Abstract]   [Full Text] [Related]  

  • 10. PEEK-OPTIMA
    Cowie RM; Briscoe A; Fisher J; Jennings LM
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1008-1015. PubMed ID: 27637723
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Failure of a metal-on-metal total hip arthroplasty from progressive osteolysis.
    Klapperich C; Graham J; Pruitt L; Ries MD
    J Arthroplasty; 1999 Oct; 14(7):877-81. PubMed ID: 10537267
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Polyethylene wear in total hip arthroplasty in patient-matched groups. A comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces.
    Bankston AB; Faris PM; Keating EM; Ritter MA
    J Arthroplasty; 1993 Jun; 8(3):315-22. PubMed ID: 8326314
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Deformation of the acetabular polyethylene liner and the backside gap.
    Yamaguchi M; Bauer TW; Hashimoto Y
    J Arthroplasty; 1999 Jun; 14(4):464-9. PubMed ID: 10428227
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wear of the polyethylene liner-metallic shell interface in modular acetabular components. An in vitro analysis.
    Lieberman JR; Kay RM; Hamlet WP; Park SH; Kabo JM
    J Arthroplasty; 1996 Aug; 11(5):602-8. PubMed ID: 8872582
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Polyethylene wear in cases using femoral stems of similar geometry, but different metals, porous layer, and modularity.
    Bal BS; Vandelune D; Gurba DM; Jasty M; Harris WH
    J Arthroplasty; 1998 Aug; 13(5):492-9. PubMed ID: 9726312
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear.
    Davidson JA
    Clin Orthop Relat Res; 1993 Sep; (294):361-78. PubMed ID: 8358943
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads.
    Galvin AL; Jennings LM; Tipper JL; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2010 Oct; 224(10):1175-83. PubMed ID: 21138235
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wear induced by motion between bone and titanium or cobalt-chrome alloys.
    Bischoff UW; Freeman MA; Smith D; Tuke MA; Gregson PJ
    J Bone Joint Surg Br; 1994 Sep; 76(5):713-6. PubMed ID: 8083256
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.
    Garvin KL; White TC; Dusad A; Hartman CW; Martell J
    Clin Orthop Relat Res; 2015 Dec; 473(12):3829-35. PubMed ID: 26122983
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.