These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
231 related articles for article (PubMed ID: 10537263)
41. Comparison of polyethylene wear in machined versus molded polyethylene. Bankston AB; Keating EM; Ranawat C; Faris PM; Ritter MA Clin Orthop Relat Res; 1995 Aug; (317):37-43. PubMed ID: 7671494 [TBL] [Abstract][Full Text] [Related]
42. Evaluation of the effect of the femoral articular surface material on the wear of a metal-backed patellar component. Milliano MT; Whiteside LA; Kaiser AD; Zwirkoski PA Clin Orthop Relat Res; 1993 Feb; (287):178-86. PubMed ID: 8448938 [TBL] [Abstract][Full Text] [Related]
44. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Lancaster JG; Dowson D; Isaac GH; Fisher J Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887 [TBL] [Abstract][Full Text] [Related]
45. Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes. Kurtz SM; Ochoa JA; Hovey CB; White CV J Biomech; 1999 Sep; 32(9):967-76. PubMed ID: 10460134 [TBL] [Abstract][Full Text] [Related]
46. Scanning Electron Microscopy and Energy-Dispersive X-Ray Spectroscopy as a Valuable Tool to Investigate the Ultra-High-Molecular-Weight Polyethylene Wear Mechanisms and Debris in Hip Implants. Schappo H; Gindri IM; Cubillos PO; Maru MM; Salmoria GV; Roesler CRM J Arthroplasty; 2018 Jan; 33(1):258-262. PubMed ID: 28844766 [TBL] [Abstract][Full Text] [Related]
47. Polyethylene sterilization and production affects wear in total hip arthroplasties. Faris PM; Ritter MA; Pierce AL; Davis KE; Faris GW Clin Orthop Relat Res; 2006 Dec; 453():305-8. PubMed ID: 16906113 [TBL] [Abstract][Full Text] [Related]
48. Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis. Oonishi H; Ueno M; Kim SC; Oonishi H; Iwamoto M; Kyomoto M J Arthroplasty; 2009 Apr; 24(3):374-82. PubMed ID: 18524533 [TBL] [Abstract][Full Text] [Related]
49. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients: a prospective randomised controlled trial. Atrey A; Ward SE; Khoshbin A; Hussain N; Bogoch E; Schemitsch EH; Waddell JP Bone Joint J; 2017 Dec; 99-B(12):1590-1595. PubMed ID: 29212681 [TBL] [Abstract][Full Text] [Related]
50. A randomized controlled trial comparing Oxinium and cobalt-chrome on standard and cross-linked polyethylene. Morison ZA; Patil S; Khan HA; Bogoch ER; Schemitsch EH; Waddell JP J Arthroplasty; 2014 Sep; 29(9 Suppl):164-8. PubMed ID: 24961892 [TBL] [Abstract][Full Text] [Related]
51. Titanium nitride ceramic film against polyethylene. A 48 million cycle wear test. Pappas MJ; Makris G; Buechel FF Clin Orthop Relat Res; 1995 Aug; (317):64-70. PubMed ID: 7671497 [TBL] [Abstract][Full Text] [Related]
52. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing. Korduba LA; Essner A; Pivec R; Lancin P; Mont MA; Wang A; Delanois RE Am J Orthop (Belle Mead NJ); 2014 Oct; 43(10):466-71. PubMed ID: 25303445 [TBL] [Abstract][Full Text] [Related]
53. Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements. Campbell P; Doorn P; Dorey F; Amstutz HC Proc Inst Mech Eng H; 1996; 210(3):167-74. PubMed ID: 8885653 [TBL] [Abstract][Full Text] [Related]
54. Hip simulator testing of the taper-trunnion junction and bearing surfaces of contemporary metal-on-cross-linked-polyethylene hip prostheses. Bhalekar RM; Smith SL; Joyce TJ J Biomed Mater Res B Appl Biomater; 2020 Jan; 108(1):156-166. PubMed ID: 30924612 [TBL] [Abstract][Full Text] [Related]
55. A wear simulation study of nanostructured CVD diamond-on-diamond articulation involving concave/convex mating surfaces. Baker PA; Thompson RG; Catledge SA J Coat Technol Res; 2016 Mar; 13(2):385-393. PubMed ID: 26989457 [TBL] [Abstract][Full Text] [Related]
56. Backside Wear Is Not Dependent on the Acetabular Socket Design in Crosslinked Polyethylene Liners. Bali K; McCalden RW; Naudie DD; MacDonald SJ; Teeter MG Clin Orthop Relat Res; 2016 Feb; 474(2):374-82. PubMed ID: 26201422 [TBL] [Abstract][Full Text] [Related]
57. Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro. Puente Reyna AL; Jäger M; Floerkemeier T; Frecher S; Delank KS; Schilling C; Grupp TM Biomed Res Int; 2016; 2016():8687131. PubMed ID: 27722174 [TBL] [Abstract][Full Text] [Related]
58. Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: a ten-year follow-up with radiostereometry. Dahl J; Söderlund P; Nivbrant B; Nordsletten L; Röhrl SM Int Orthop; 2012 Mar; 36(3):485-90. PubMed ID: 21870101 [TBL] [Abstract][Full Text] [Related]
59. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055 [TBL] [Abstract][Full Text] [Related]
60. A Polished Cobalt-Chrome Baseplate is not Associated With a Lower Revision Rate Than Matt Titanium in a Single Total Knee Arthroplasty Implant System With Identical Baseplate Design. Zhou Y; Harries D; Stoney JD J Arthroplasty; 2024 Apr; 39(4):896-903. PubMed ID: 37852451 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]