These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 10548378)

  • 21. [Therapy of thromboembolic blockages in the crural arteries: Clinical experience with the Angiojet thrombectomy catheter].
    Pitton MB; Neufang A; Düber C
    Rofo; 1999 Nov; 171(5):380-5. PubMed ID: 10619040
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Technical modification of the rheolytic thrombectomy].
    Müller-Hülsbeck S; Link J; Schwarzenberg H; Brossmann J; Heller M
    Rofo; 1996 Jun; 164(6):507-10. PubMed ID: 8688509
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A new thrombectomy catheter device (AngioJet) for the disruption of thrombi: An in vitro study.
    Stähr P; Rupprecht HJ; Voigtländer T; Post F; Otto M; Erbel R; Meyer J
    Catheter Cardiovasc Interv; 1999 Jul; 47(3):381-9. PubMed ID: 10402302
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Mechanical thromboembolectomy for acute ischemic stroke: comparison of the catch thrombectomy device and the Merci Retriever in vivo.
    Brekenfeld C; Schroth G; El-Koussy M; Nedeltchev K; Reinert M; Slotboom J; Gralla J
    Stroke; 2008 Apr; 39(4):1213-9. PubMed ID: 18309173
    [TBL] [Abstract][Full Text] [Related]  

  • 25. No inferiority of Tonbridge thrombectomy device for acute thrombus retrial compared with Solitaire device: an experimental evaluation with a canine distal external carotid-maxillary artery occlusion model.
    Zhou G; Li MH; Lu HT; Deng JS; Zhao YW; Wang YXJ; Zhu YQ
    J Neurointerv Surg; 2018 Nov; 10(11):1085-1091. PubMed ID: 29444961
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Percutaneous transluminal hydrodynamic thrombectomy--the initial results].
    Höpfner W; Vicol C; Bohndorf K; Loeprecht H
    Rofo; 1996 Feb; 164(2):141-5. PubMed ID: 8679976
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mechanical thrombolysis of acute occlusion of both the superficial and the deep femoral arteries using a thrombectomy device.
    Görich J; Rilinger N; Sokiranski R; Krämer S; Mickley V; Schütz A; Brambs HJ; Pamler R
    AJR Am J Roentgenol; 1998 May; 170(5):1177-80. PubMed ID: 9574579
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Thrombectomy for acute internal carotid thrombosis: five thrombectomy devices compared.
    Chant H; Ashleigh R; McCollum C
    Eur J Vasc Endovasc Surg; 2004 Apr; 27(4):403-8. PubMed ID: 15015191
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Safety and efficacy of the AngioJet in patients with acute myocardial infarction: results from the Florence Appraisal Study of Rheolytic Thrombectomy (FAST).
    Margheri M; Falai M; Vittori G; Zoccai GG; Chechi T; Ricceri I; Falchetti E; Comeglio M; Giglioli C; Valente S; Gensini GF
    J Invasive Cardiol; 2006 Oct; 18(10):481-6. PubMed ID: 17235420
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Novel use of the Heartrail catheter as a thrombectomy device.
    Hadi HM; Fraser DG; Mamas MA
    J Invasive Cardiol; 2011 Jan; 23(1):35-40. PubMed ID: 21183769
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Percutaneous mechanical thrombectomy using Rotarex catheter in peripheral artery occlusion diseases - Experience from a single center.
    Liu J; Li T; Huang W; Zhao N; Liu H; Zhao H; Wang H
    Vascular; 2019 Apr; 27(2):199-203. PubMed ID: 30458685
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Acute superior mesenteric artery embolism: reperfusion with AngioJet hydrodynamic suction thrombectomy and pharmacologic thrombolysis with the EKOS catheter.
    Ballehaninna UK; Hingorani A; Ascher E; Shiferson A; Marks N; Aboian E; Jimenez R; Jacob T; McIntyre T
    Vascular; 2012 Jun; 20(3):166-9. PubMed ID: 22442382
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing.
    Kucher N; Windecker S; Banz Y; Schmitz-Rode T; Mettler D; Meier B; Hess OM
    Radiology; 2005 Sep; 236(3):852-8. PubMed ID: 16014440
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Preclinical evaluation of a rheolytic catheter for percutaneous coronary artery/saphenous vein graft thrombectomy.
    Henry TD; Setum CM; Wilson GJ; Morris JE; Johnston RB; Jenson ML
    J Invasive Cardiol; 1999 Aug; 11(8):475-84. PubMed ID: 10745578
    [TBL] [Abstract][Full Text] [Related]  

  • 35. In vitro experiments of cerebral blood flow during aspiration thrombectomy: potential effects on cerebral perfusion pressure and collateral flow.
    Lally F; Soorani M; Woo T; Nayak S; Jadun C; Yang Y; McCrudden J; Naire S; Grunwald I; Roffe C
    J Neurointerv Surg; 2016 Sep; 8(9):969-72. PubMed ID: 26320121
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of the mechanical thrombectomy efficacy of the Amplatz thrombectomy device and the Cragg thrombolytic brush in vitro.
    Grimm J; Müller-Hülsbeck S; Heller M
    Invest Radiol; 2001 Apr; 36(4):204-9. PubMed ID: 11283417
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Thrombectomy with the hydrolysing catheter. Apropos of 50 cases].
    Henry M; Amor M; Henry I; Tricoche O; Allaoui M
    Arch Mal Coeur Vaiss; 1997 Jun; 90(6):797-804. PubMed ID: 9295932
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparisons of clinical outcomes for thrombectomy devices with different mechanisms in hemodialysis arteriovenous fistulas.
    Yang CC; Yang CW; Wen SC; Wu CC
    Catheter Cardiovasc Interv; 2012 Nov; 80(6):1035-41. PubMed ID: 22511560
    [TBL] [Abstract][Full Text] [Related]  

  • 39. How thrombus model impacts the in vitro study of interventional thrombectomy procedures.
    Krueger K; Deissler P; Coburger S; Fries JW; Lackner K
    Invest Radiol; 2004 Oct; 39(10):641-8. PubMed ID: 15377944
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Stent retriever thrombectomy with the Cover accessory device versus proximal protection with a balloon guide catheter: in vitro stroke model comparison.
    Mokin M; Setlur Nagesh SV; Ionita CN; Mocco J; Siddiqui AH
    J Neurointerv Surg; 2016 Apr; 8(4):413-7. PubMed ID: 25676149
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.