These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
103 related articles for article (PubMed ID: 10548378)
41. Treatment of basilar artery embolism with a mechanical extraction device: necessity of flow reversal. Mayer TE; Hamann GF; Brueckmann HJ Stroke; 2002 Sep; 33(9):2232-5. PubMed ID: 12215592 [TBL] [Abstract][Full Text] [Related]
42. Rapid thrombectomy with a hydrodynamic catheter: results from a prospective, multicenter trial. Wagner HJ; Müller-Hülsbeck S; Pitton MB; Weiss W; Wess M Radiology; 1997 Dec; 205(3):675-81. PubMed ID: 9393520 [TBL] [Abstract][Full Text] [Related]
43. Rotational thrombectomy of acute peripheral vascular occlusions using the ThromCat XT device: techniques, indications and initial results. Deák Z; Strube H; Sadeghi-Azandaryani M; Reiser MF; Treitl M Diagn Interv Radiol; 2011 Sep; 17(3):283-9. PubMed ID: 20976670 [TBL] [Abstract][Full Text] [Related]
44. Microcatheter navigation through the clot: does size matter? Caroff J; King RM; Arslanian R; Marosfoi M; Langan ET; Gounis MJ; Chueh JY J Neurointerv Surg; 2019 Mar; 11(3):271-274. PubMed ID: 30177546 [TBL] [Abstract][Full Text] [Related]
45. Device and imaging-specific volumetric analysis of clot lysis after percutaneous mechanical thrombectomy for iliofemoral DVT. Murphy EH; Broker HS; Johnson EJ; Modrall JG; Valentine RJ; Arko FR J Endovasc Ther; 2010 Jun; 17(3):423-33. PubMed ID: 20557187 [TBL] [Abstract][Full Text] [Related]
46. Efficacy of Mechanical Thrombectomy Using Stent Retriever and Balloon-Guiding Catheter. Kammerer S; du Mesnil de Rochemont R; Wagner M; You S-; Tritt S; Mueller-Eschner M; Keil FC; Lauer A; Berkefeld J Cardiovasc Intervent Radiol; 2018 May; 41(5):699-705. PubMed ID: 29468288 [TBL] [Abstract][Full Text] [Related]
47. Comparison of arterial wall reaction after passage of the Hydrolyser device versus a thrombectomy balloon in an animal model. van Ommen VG; van der Veen FH; Geskes GG; Daemen M; Habets J; Dassen WR; Wellens HJ J Vasc Interv Radiol; 1996; 7(3):451-4. PubMed ID: 8761831 [TBL] [Abstract][Full Text] [Related]
48. Thrombectomy and distal protection devices. Rajagopal R; Musto C; La Manna A; Tanigawa J; Goktekin O; Di Mario C Minerva Cardioangiol; 2005 Oct; 53(5):415-30. PubMed ID: 16179884 [TBL] [Abstract][Full Text] [Related]
49. Endovascular Revascularization of Hemodialysis Thrombosed Grafts with the Hydrodynamic Thrombectomy Catheter. Our 7-Year Experience. Bermudez P; Fontseré N; Mestres G; García-Gámez A; Barrufet M; Burrel M; Gilabert R; Gómez F; Macho J Cardiovasc Intervent Radiol; 2017 Feb; 40(2):252-259. PubMed ID: 27896413 [TBL] [Abstract][Full Text] [Related]
50. Effective use of balloon guide catheters in reducing incidence of mechanical thrombectomy related distal embolization. Lee DH; Sung JH; Kim SU; Yi HJ; Hong JT; Lee SW Acta Neurochir (Wien); 2017 Sep; 159(9):1671-1677. PubMed ID: 28691137 [TBL] [Abstract][Full Text] [Related]
51. Recanalization of thrombosed superficial femoral arteries with a hydraulic thrombectomy catheter in a canine model. Qian Z; Wholey M; Ferral H; Maynar M; Postoak D; Hamide J; Newman WP; Moncada R; Gonzalez-Roman A; Gimenez C; Castañeda WR AJR Am J Roentgenol; 1999 Dec; 173(6):1557-63. PubMed ID: 10584801 [TBL] [Abstract][Full Text] [Related]
52. Improvement of stent retriever design and efficacy of mechanical thrombectomy in a flow model. Wenger K; Nagl F; Wagner M; Berkefeld J Cardiovasc Intervent Radiol; 2013 Feb; 36(1):192-7. PubMed ID: 22699778 [TBL] [Abstract][Full Text] [Related]
53. A retrieval thrombectomy technique with the Solitaire stent in a large cerebral artery occlusion. Park H; Hwang GJ; Jin SC; Jung CK; Bang JS; Han MK; Bae HJ; Choe GY; Oh CW; Kwon OK Acta Neurochir (Wien); 2011 Aug; 153(8):1625-31. PubMed ID: 21479799 [TBL] [Abstract][Full Text] [Related]
54. Comparison of a Balloon Guide Catheter and a Non-Balloon Guide Catheter for Mechanical Thrombectomy. Velasco A; Buerke B; Stracke CP; Berkemeyer S; Mosimann PJ; Schwindt W; Alcázar P; Cnyrim C; Niederstadt T; Chapot R; Heindel W Radiology; 2016 Jul; 280(1):169-76. PubMed ID: 26789499 [TBL] [Abstract][Full Text] [Related]
55. Functional properties of a prototype rheolytic catheter for percutaneous thrombectomy. In vitro investigations. Douek PC; Gandjbakhche A; Leon MB; Bonner RF Invest Radiol; 1994 May; 29(5):547-52. PubMed ID: 8077094 [TBL] [Abstract][Full Text] [Related]
56. Comparison of ASPIRE Mechanical Thrombectomy Versus AngioJet Thrombectomy System in a Porcine Iliac Vein Thrombosis Model. Weinberg RJ; Okada T; Chen A; Kim W; Chen C; Lin PH Ann Vasc Surg; 2017 Jul; 42():254-262. PubMed ID: 28389294 [TBL] [Abstract][Full Text] [Related]
57. Thrombectomy with AngioJet catheter in native coronary arteries for patients with acute or recent myocardial infarction. Nakagawa Y; Matsuo S; Kimura T; Yokoi H; Tamura T; Hamasaki N; Nosaka H; Nobuyoshi M Am J Cardiol; 1999 Apr; 83(7):994-9. PubMed ID: 10190508 [TBL] [Abstract][Full Text] [Related]
58. Massive air embolus treated with rheolytic thrombectomy. Dudar BM; Kim HE J Invasive Cardiol; 2007 Jul; 19(7):E182-4. PubMed ID: 17620682 [TBL] [Abstract][Full Text] [Related]
59. [Percutaneous therapy of occlusions of calf arteries with newly developed hydrodynamic thrombectomy catheter, Angiojet LF140]. Müller-Hülsbeck S; Brossmann J; Heller M Rofo; 1998 May; 168(5):514-7. PubMed ID: 9617370 [TBL] [Abstract][Full Text] [Related]