BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 10554342)

  • 1. Concentric wear of the Delrin disc in a Bjork-Shiley heart valve prosthesis: report of two cases.
    Aoyagi S; Tayama K; Tayama E; Fukunaga S; Akashi H; Kawara T; Oryoji A
    Surg Today; 1999; 29(10):1115-9. PubMed ID: 10554342
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surface and edge wear of Björk-Shiley Delrin heart valve discs.
    Engel PA; Clark ES; Park SH; McKellop H; Thyagarajan K; Zhao Z; Campbell P; Wieting DW
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S190-205. PubMed ID: 8905520
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A case report of valve dysfunction associated with abrasion of the Delrin disk used in early Björk-Shiley mitral valves requiring resurgery.
    Masumoto H; Shimamoto M; Yamazaki F; Nakai M; Fujita S; Miura Y; Itonaga T; Ito H
    Ann Thorac Cardiovasc Surg; 2009 Apr; 15(2):126-8. PubMed ID: 19471217
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Björk-Shiley Delrin tilting disc heart valve: historical perspective, design and need for scientific analyses after 25 years.
    Wieting DW
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S157-68. PubMed ID: 8905516
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of wear patterns in vivo and in vitro for Björk-Shiley Delrin heart valve discs.
    Thyagarajan K; Conlin C; Milligan HL; Wieting DW
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S206-15. PubMed ID: 8905521
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Report of a case with re-mitral valve replacement for Björk-Shiley Delrin disc valve prosthesis--disc wear of the Delrin disc 20 years after implantation].
    Abe M; Sakai A; Lin ZB; Hanayama N; Oosawa M
    Nihon Kyobu Geka Gakkai Zasshi; 1996 Apr; 44(4):545-7. PubMed ID: 8666877
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Late malfunction of the Björk-Shiley valve prosthesis due to Delrin disc defacement].
    Katsumata T; Shimakura T; Nakano H; Shimamura Y; Hoshino K; Harada T; Maejima F; Kohno H; Asakawa K; Yabuki A
    Kyobu Geka; 1993 Nov; 46(12):1059-62. PubMed ID: 8230934
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study.
    Lindower PD; Dellsperger KC; Johnson B; Chandran KB; Vandenberg BF
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S178-83. PubMed ID: 8905518
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ex-vivo characterization of three Björk-Shiley Delrin heart valves.
    Farè S; Brunella MF; Bruschi G; Vitali E
    J Heart Valve Dis; 2008 May; 17(3):325-31. PubMed ID: 18592930
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Summary and recommendations.
    Stein PD; Dellsperger KC
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S246-8. PubMed ID: 8905526
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical experience with the Björk-Shiley Delrin tilting disc heart valve.
    Dellsperger KC; Grunkemeier GL; Stein PD
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S169-77. PubMed ID: 8905517
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Replacement of a Björk-Shiley Delrin aortic valve still functioning after 25 years.
    Badak MI; Ozkisacik EA; Boga M; Gurcun U; Discigil B
    Tex Heart Inst J; 2004; 31(3):303-5; discussion 305. PubMed ID: 15562853
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of disc retention of Björk-Shiley Delrin heart valves.
    Thyagarajan K; Conlin CH; Wieting DW
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S243-5. PubMed ID: 8905525
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Structural analysis of the Björk-Shiley Delrin heart valve occluder.
    McMeeking RM; He MY; Chia R
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S229-37. PubMed ID: 8905523
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reoperation for a Starr-Edwards aortic prosthetic valve 33 years after initial implantation.
    Misumi T; Kudo M; Koizumi K; Kumamaru H
    Jpn J Thorac Cardiovasc Surg; 2005 Mar; 53(3):165-8. PubMed ID: 15828300
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Complete Transversal Disc Fracture in a Björk-Shiley Delrin Mitral Valve Prosthesis 43 Years After Implantation.
    González-Santos JM; Arnáiz-García ME; Dalmau-Sorlí MJ; Sastre-Rincón JA; Hernández-Hernández J; Pérez-Losada ME; Sagredo-Meneses V; López-Rodríguez J
    Ann Thorac Surg; 2016 Oct; 102(4):e283-5. PubMed ID: 27645963
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Unexpected durability of a Björk-Shiley first-generation aortic valve after 40 years of implantation.
    Brizzio ME; Zapolanski A; Pantazopoulos J; Mentakis M
    J Heart Valve Dis; 2010 Jan; 19(1):149-51. PubMed ID: 20329501
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reoperation for a patient 25 years after a Starr-Edwards ball mitral valve was installed.
    Ye Z; Shiono M; Sezai A; Inoue T; Hata M; Niino T; Goshima M; Nakamura T; Negishi N; Sezai Y
    Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):311-5. PubMed ID: 12472416
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The 37-year durability of a Björk-Shiley Delrin-disc aortic valve prosthesis.
    Sansone F; Zingarelli E; Actis Dato GM; Punta G; Flocco R; del Ponte S; Casabona R
    Tex Heart Inst J; 2012; 39(2):284-5. PubMed ID: 22740755
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Late results of valve replacement with the Björk-Shiley valve (1973 to 1982).
    Orszulak TA; Schaff HV; DeSmet JM; Danielson GK; Pluth JR; Puga FJ
    J Thorac Cardiovasc Surg; 1993 Feb; 105(2):302-12. PubMed ID: 8429659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.