181 related articles for article (PubMed ID: 10554342)
21. [Reoperation for a Starr-Edwards ball valve prosthesis implanted in mitral position 31 years ago].
Goshima M; Shiono M; Yamamoto T; Inoue T; Hata M; Sezai A; Niino T; Nakamura T; Ye Z; Negishi N; Sezai Y
Kyobu Geka; 2003 Jul; 56(7):535-40. PubMed ID: 12854458
[TBL] [Abstract][Full Text] [Related]
22. Triple Björk-Shiley valve--more than 30 years of asymptomatic functioning: to the memory of late academic prof. Isidor Papo and the 45th anniversary of the first valve implantation in Yugoslavia.
Krotin M; Krotin JM; Zdravković M
Vojnosanit Pregl; 2010 Aug; 67(8):685-7. PubMed ID: 20845674
[TBL] [Abstract][Full Text] [Related]
23. Björk-Shiley and Carpentier-Edwards valves. A comparative analysis.
Nashef SA; Sethia B; Turner MA; Davidson KG; Lewis S; Bain WH
J Thorac Cardiovasc Surg; 1987 Mar; 93(3):394-404. PubMed ID: 3821149
[TBL] [Abstract][Full Text] [Related]
24. Theory of wear as related to the Björk-Shiley Delrin disc heart valve.
Engel PA; Zhao Z; Yang Q; Lin S; Rattazzi D
J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S216-28. PubMed ID: 8905522
[TBL] [Abstract][Full Text] [Related]
25. Acute postoperative block of mechanical prostheses: incidence and treatment.
Santé P; Renzulli A; Festa M; Vitale N; Mollo A; Dialetto G; De Luca L
Cardiovasc Surg; 1994 Jun; 2(3):403-6. PubMed ID: 8049985
[TBL] [Abstract][Full Text] [Related]
26. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].
Minardi G; Di Segni M; Boccardi L; Ferrari O; Giovannini E
G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201
[TBL] [Abstract][Full Text] [Related]
27. Strut fracture in a Bjork-Shiley aortic valve prosthesis.
Lifschultz BD; Donoghue ER
J Forensic Sci; 1985 Oct; 30(4):1244-7. PubMed ID: 4067547
[TBL] [Abstract][Full Text] [Related]
28. Excellent durability of Starr-Edwards ball valves implanted in the aortic and mitral positions for 27 years: report of a rare surgical case.
Tochii M; Takagi Y; Kaneko K; Ishida M; Akita K; Higuchi Y; Ando M
Ann Thorac Cardiovasc Surg; 2013; 19(1):76-8. PubMed ID: 22785448
[TBL] [Abstract][Full Text] [Related]
29. [Malfunction of the Björk-Shiley valve prosthesis due to disc defacement--report of two cases of successful reoperation].
Misumi H; Matsuo K; Ishihara K; Nakae S; Hashimoto A; Koyanagi H
Nihon Kyobu Geka Gakkai Zasshi; 1989 Mar; 37(3):522-8. PubMed ID: 2768926
[TBL] [Abstract][Full Text] [Related]
30. An examination of two retrieved long-term human implant Björk-Shiley valves.
More RB
Med Prog Technol; 1994; 20(3-4):195-200. PubMed ID: 7877565
[TBL] [Abstract][Full Text] [Related]
31. [Long-term results of cardiac valve replacement with a Delrin-disk model of the Björk-Shiley valve prosthesis--comparative analysis with the Spherical-disk model].
Hirai M; Kitamura M; Aomi S; Hachida M; Nakano H; Ohtsuka G; Yamaki F; Endo M; Hashimoto A; Koyanagi H
Nihon Kyobu Geka Gakkai Zasshi; 1996 Nov; 44(11):1986-92. PubMed ID: 8958712
[TBL] [Abstract][Full Text] [Related]
32. Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.
Tayama K; Akashi H; Tayama E; Fukunaga S; Kawara T; Kosuga K; Aoyagi S
Circ J; 2004 May; 68(5):507-8. PubMed ID: 15118298
[TBL] [Abstract][Full Text] [Related]
33. The clinical life history of explanted prosthetic heart valves.
Marbarger JP; Clark RE
Ann Thorac Surg; 1982 Jul; 34(1):22-33. PubMed ID: 7092396
[TBL] [Abstract][Full Text] [Related]
34. Disc wear and entrapment in a Starr-Edwards mitral caged-disc valve.
Aoyagi S; Fukunaga S; Arinaga K
J Heart Valve Dis; 2011 Jul; 20(4):474-6. PubMed ID: 21863665
[TBL] [Abstract][Full Text] [Related]
35. [Functional transvalvular regurgitation in patients with Björk-Shiley aortic valves: a pulsed Doppler echocardiographic study].
Yoshida K; Yoshikawa J; Kato H; Yanagihara K; Okumachi F; Koizumi K; Shiratori K; Asaka T; Suzuki K; Inanami H
J Cardiogr; 1985 Dec; 15(4):1137-44. PubMed ID: 3841896
[TBL] [Abstract][Full Text] [Related]
36. Bentall procedure 39 years after implantation of a Starr-Edwards aortic caged-ball-valve prosthesis.
Schmitto JD; Ortmann P; Popov AF; Coskun KO; Schotola H; Friedrich M; Wiese CH; Sohns C; Mokashi SA; Didilis VN; Schoendube FA
J Cardiothorac Surg; 2010 Mar; 5():12. PubMed ID: 20298579
[TBL] [Abstract][Full Text] [Related]
37. Prophylactic reoperation after mitral valve replacement with the Starr-Edwards ball valve: a report of four cases.
Sezai A; Hata M; Niino T; Yoda M; Wakui S; Umeda T; Shimura K; Furukawa N; Tokai K; Kasamaki Y; Minami K
Ann Thorac Cardiovasc Surg; 2007 Oct; 13(5):316-21. PubMed ID: 17954988
[TBL] [Abstract][Full Text] [Related]
38. Leaflet tear in a Trifecta aortic bioprosthesis 34 months after implantation.
Piñón M; Durán D; Pazos P; Pradas G
Interact Cardiovasc Thorac Surg; 2015 Feb; 20(2):281-2. PubMed ID: 25404230
[TBL] [Abstract][Full Text] [Related]
39. Excellence and Durability: A Normally Functioning Björk-Shiley Flat-Disc Prosthesis 42 Years Post Implantation.
Shaikh A; Jamil Tajik A
J Heart Valve Dis; 2016 Mar; 25(2):237-239. PubMed ID: 27989074
[TBL] [Abstract][Full Text] [Related]
40. [A case of acute extrinsic malfunction of prosthetic valve due to suture tag causing incomplete closure of the disc].
Miyahara K; Kawase M; Sakakibara T; Ida T; Mannoji E; Hayashi K; Amano T; Shibuya M
Kyobu Geka; 1992 Jul; 45(7):635-9. PubMed ID: 1619830
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]