121 related articles for article (PubMed ID: 10559750)
1. Effects of sterilization processes on NiTi alloy: surface characterization.
Thierry B; Tabrizian M; Savadogo O; Yahia L
J Biomed Mater Res; 2000 Jan; 49(1):88-98. PubMed ID: 10559750
[TBL] [Abstract][Full Text] [Related]
2. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy.
Thierry B; Tabrizian M; Trepanier C; Savadogo O; Yahia L
J Biomed Mater Res; 2000 Sep; 51(4):685-93. PubMed ID: 10880117
[TBL] [Abstract][Full Text] [Related]
3. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments.
Spagnuolo G; Ametrano G; D'Antò V; Rengo C; Simeone M; Riccitiello F; Amato M
Int Endod J; 2012 Dec; 45(12):1148-55. PubMed ID: 22757632
[TBL] [Abstract][Full Text] [Related]
4. Surface finishing of Nitinol for implantable medical devices: A review.
Mani G; Porter D; Grove K; Collins S; Ornberg A; Shulfer R
J Biomed Mater Res B Appl Biomater; 2022 Dec; 110(12):2763-2778. PubMed ID: 35729868
[TBL] [Abstract][Full Text] [Related]
5. Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium.
Vezeau PJ; Koorbusch GF; Draughn RA; Keller JC
J Oral Maxillofac Surg; 1996 Jun; 54(6):738-46. PubMed ID: 8648479
[TBL] [Abstract][Full Text] [Related]
6. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution.
Cissé O; Savadogo O; Wu M; Yahia L
J Biomed Mater Res; 2002 Sep; 61(3):339-45. PubMed ID: 12115458
[TBL] [Abstract][Full Text] [Related]
7. Multi-scale characterization and biological evaluation of composite surface layers produced under glow discharge conditions on NiTi shape memory alloy for potential cardiological application.
Chlanda A; Witkowska J; Morgiel J; Nowińska K; Choińska E; Swieszkowski W; Wierzchoń T
Micron; 2018 Nov; 114():14-22. PubMed ID: 30056255
[TBL] [Abstract][Full Text] [Related]
8. Biomimetic deposition of apatite coating on surface-modified NiTi alloy.
Gu YW; Tay BY; Lim CS; Yong MS
Biomaterials; 2005 Dec; 26(34):6916-23. PubMed ID: 15941583
[TBL] [Abstract][Full Text] [Related]
9. An evaluation of two types of nickel-titanium wires in terms of micromorphology and nickel ions' release following oral environment exposure.
Ghazal AR; Hajeer MY; Al-Sabbagh R; Alghoraibi I; Aldiry A
Prog Orthod; 2015; 16():9. PubMed ID: 26061986
[TBL] [Abstract][Full Text] [Related]
10. Effect of modification of oxide layer on NiTi stent corrosion resistance.
Trépanier C; Tabrizian M; Yahia LH; Bilodeau L; Piron DL
J Biomed Mater Res; 1998; 43(4):433-40. PubMed ID: 9855202
[TBL] [Abstract][Full Text] [Related]
11. Behaviour of human endothelial cells on surface modified NiTi alloy.
Plant SD; Grant DM; Leach L
Biomaterials; 2005 Sep; 26(26):5359-67. PubMed ID: 15814134
[TBL] [Abstract][Full Text] [Related]
12. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy.
Chu CL; Guo C; Sheng XB; Dong YS; Lin PH; Yeung KW; Chu PK
Acta Biomater; 2009 Jul; 5(6):2238-45. PubMed ID: 19251496
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of passive oxide layer formation-biocompatibility relationship in NiTi shape memory alloys: geometry and body location dependency.
Toker SM; Canadinc D; Maier HJ; Birer O
Mater Sci Eng C Mater Biol Appl; 2014 Mar; 36():118-29. PubMed ID: 24433894
[TBL] [Abstract][Full Text] [Related]
14. The effect of heating rate on the surface chemistry of NiTi.
Undisz A; Hanke R; Freiberg KE; Hoffmann V; Rettenmayr M
Acta Biomater; 2014 Nov; 10(11):4919-4923. PubMed ID: 25064001
[TBL] [Abstract][Full Text] [Related]
15. Biocompatibility and hemocompatibility of surface-modified NiTi alloys.
Armitage DA; Parker TL; Grant DM
J Biomed Mater Res A; 2003 Jul; 66(1):129-37. PubMed ID: 12833439
[TBL] [Abstract][Full Text] [Related]
16. Surface oxide net charge of a titanium alloy: comparison between effects of treatment with heat or radiofrequency plasma glow discharge.
MacDonald DE; Rapuano BE; Schniepp HC
Colloids Surf B Biointerfaces; 2011 Jan; 82(1):173-81. PubMed ID: 20880672
[TBL] [Abstract][Full Text] [Related]
17. Influence of autoclave sterilization on the surface parameters and mechanical properties of six orthodontic wires.
Pernier C; Grosgogeat B; Ponsonnet L; Benay G; Lissac M
Eur J Orthod; 2005 Feb; 27(1):72-81. PubMed ID: 15743866
[TBL] [Abstract][Full Text] [Related]
18. Electrochemical and surface characterization of a nickel-titanium alloy.
Wever DJ; Veldhuizen AG; de Vries J; Busscher HJ; Uges DR; van Horn JR
Biomaterials; 1998; 19(7-9):761-9. PubMed ID: 9663751
[TBL] [Abstract][Full Text] [Related]
19. Morphological characterization and in vitro biocompatibility of a porous nickel-titanium alloy.
Prymak O; Bogdanski D; Köller M; Esenwein SA; Muhr G; Beckmann F; Donath T; Assad M; Epple M
Biomaterials; 2005 Oct; 26(29):5801-7. PubMed ID: 15949545
[TBL] [Abstract][Full Text] [Related]
20. Mechanism of oxide layer growth during annealing of NiTi.
Undisz A; Schrempel F; Wesch W; Rettenmayr M
J Biomed Mater Res A; 2012 Jul; 100(7):1743-50. PubMed ID: 22467267
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]