These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 10559750)

  • 21. Load-deflection characteristics of nickel-titanium alloy wires after clinical recycling and dry heat sterilization.
    Kapila S; Haugen JW; Watanabe LG
    Am J Orthod Dentofacial Orthop; 1992 Aug; 102(2):120-6. PubMed ID: 1636628
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of thermomechanical pre-treatment on short- and long-term Ni release from biomedical NiTi.
    Freiberg KE; Bremer-Streck S; Kiehntopf M; Rettenmayr M; Undisz A
    Acta Biomater; 2014 May; 10(5):2290-5. PubMed ID: 24418435
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Surface characteristics, corrosion and bioactivity of chemically treated biomedical grade NiTi alloy.
    Chembath M; Balaraju JN; Sujata M
    Mater Sci Eng C Mater Biol Appl; 2015 Nov; 56():417-25. PubMed ID: 26249609
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Improved endothelialization of NiTi alloy by VEGF functionalized nanocoating.
    Shen W; Cai K; Yang Z; Yan Y; Yang W; Liu P
    Colloids Surf B Biointerfaces; 2012 Jun; 94():347-53. PubMed ID: 22387019
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Thermoelastic analysis of nickel-titanium endodontic files].
    Rapisarda E; Tripi TR; Bonaccorso A
    Minerva Stomatol; 2000 Mar; 49(3):93-9. PubMed ID: 20047207
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Variation in corrosion resistance of nickel-titanium wires from different manufacturers.
    Huang HH
    Angle Orthod; 2005 Jul; 75(4):661-5. PubMed ID: 16097238
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Surface oxidation of NiTi shape memory alloy.
    Firstov GS; Vitchev RG; Kumar H; Blanpain B; Van Humbeeck J
    Biomaterials; 2002 Dec; 23(24):4863-71. PubMed ID: 12361627
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effects of clinical recycling on mechanical properties of nickel-titanium alloy wires.
    Kapila S; Reichhold GW; Anderson RS; Watanabe LG
    Am J Orthod Dentofacial Orthop; 1991 Nov; 100(5):428-35. PubMed ID: 1951195
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Nickel release behavior and surface characteristics of porous NiTi shape memory alloy modified by different chemical processes.
    Wu S; Liu X; Chan YL; Chu PK; Chung CY; Chu C; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2009 May; 89(2):483-9. PubMed ID: 18431757
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Variation in surface topography of different NiTi orthodontic archwires in various commercial fluoride-containing environments.
    Huang HH
    Dent Mater; 2007 Jan; 23(1):24-33. PubMed ID: 16417915
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids.
    Serro AP; Saramago B
    Biomaterials; 2003 Nov; 24(26):4749-60. PubMed ID: 14530072
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments.
    Plotino G; Costanzo A; Grande NM; Petrovic R; Testarelli L; Gambarini G
    J Endod; 2012 Feb; 38(2):222-5. PubMed ID: 22244641
    [TBL] [Abstract][Full Text] [Related]  

  • 34. NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization.
    Yahia LH; Lombardi S; Piron D; Klemberg-Sapieha JE; Wertheimer MR
    Med Prog Technol; 1996-1997; 21(4):187-93. PubMed ID: 9110276
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages.
    Liu XM; Wu SL; Chan YL; Chu PK; Chung CY; Chu CL; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2007 Aug; 82(2):469-78. PubMed ID: 17295249
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of sterilization on poly(ethylene glycol) hydrogels.
    Kanjickal D; Lopina S; Evancho-Chapman MM; Schmidt S; Donovan D
    J Biomed Mater Res A; 2008 Dec; 87(3):608-17. PubMed ID: 18186054
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Adsorption of human plasma proteins to modified titanium surfaces.
    Sela MN; Badihi L; Rosen G; Steinberg D; Kohavi D
    Clin Oral Implants Res; 2007 Oct; 18(5):630-8. PubMed ID: 17484735
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ni ion release, osteoblast-material interactions, and hemocompatibility of hafnium-implanted NiTi alloy.
    Zhao T; Li Y; Zhao X; Chen H; Zhang T
    J Biomed Mater Res B Appl Biomater; 2012 Apr; 100(3):646-59. PubMed ID: 22121018
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Nitride coating enhances endothelialization on biomedical NiTi shape memory alloy.
    Ion R; Luculescu C; Cimpean A; Marx P; Gordin DM; Gloriant T
    Mater Sci Eng C Mater Biol Appl; 2016 May; 62():686-91. PubMed ID: 26952473
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of ion-implantation on surface characteristics of nickel titanium and titanium molybdenum alloy arch wires.
    Krishnan M; Saraswathy S; Sukumaran K; Abraham KM
    Indian J Dent Res; 2013; 24(4):411-7. PubMed ID: 24047831
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.