These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 10559750)

  • 41. Surface characterizations of laser modified biomedical grade NiTi shape memory alloys.
    Pequegnat A; Michael A; Wang J; Lian K; Zhou Y; Khan MI
    Mater Sci Eng C Mater Biol Appl; 2015 May; 50():367-78. PubMed ID: 25746282
    [TBL] [Abstract][Full Text] [Related]  

  • 42. PIIID-formed (Ti, O)/Ti, (Ti, N)/Ti and (Ti, O, N)/Ti coatings on NiTi shape memory alloy for medical applications.
    Sun T; Wang LP; Wang M; Tong HW; Lu WW
    Mater Sci Eng C Mater Biol Appl; 2012 Aug; 32(6):1469-79. PubMed ID: 24364947
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The atomic level structure of the TiO(2)-NiTi interface.
    Nolan M; Tofail SA
    Phys Chem Chem Phys; 2010 Sep; 12(33):9742-50. PubMed ID: 20552125
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.
    Yılmaz K; Uslu G; Özyürek T
    Clin Oral Investig; 2018 Dec; 22(9):2975-2980. PubMed ID: 29442187
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity.
    Huang HH
    J Biomed Mater Res A; 2005 Sep; 74(4):629-39. PubMed ID: 16025472
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Hybrid a-CNH+TiO
    Witkowska J; Sowińska A; Czarnowska E; Płociński T; Kamiński J; Wierzchoń T
    Nanomedicine (Lond); 2017 Sep; 12(18):2233-2244. PubMed ID: 28818003
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Corrosion resistance of NiTi in fluoride and acid environments.
    Benyahia H; Ebntouhami M; Forsal I; Zaoui F; Aalloula E
    Int Orthod; 2009 Dec; 7(4):322-34. PubMed ID: 20303919
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Effects of sterilization on the mechanical properties and the surface topography of nickel-titanium arch wires.
    Mayhew MJ; Kusy RP
    Am J Orthod Dentofacial Orthop; 1988 Mar; 93(3):232-6. PubMed ID: 3422779
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Evaluation of surface topography changes in three NiTi file systems using rotary and reciprocal motion: An atomic force microscopy study.
    Fatma Y; Ozgur U
    Microsc Res Tech; 2014 Mar; 77(3):177-82. PubMed ID: 24375725
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Influence of TiN coating on the biocompatibility of medical NiTi alloy.
    Jin S; Zhang Y; Wang Q; Zhang D; Zhang S
    Colloids Surf B Biointerfaces; 2013 Jan; 101():343-9. PubMed ID: 23010039
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Surface characterization of titanium-based implant materials.
    Placko HE; Mishra S; Weimer JJ; Lucas LC
    Int J Oral Maxillofac Implants; 2000; 15(3):355-63. PubMed ID: 10874800
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The underlying biological mechanisms of biocompatibility differences between bare and TiN-coated NiTi alloys.
    Lifeng Z; Yan H; Dayun Y; Xiaoying L; Tingfei X; Deyuan Z; Ying H; Jinfeng Y
    Biomed Mater; 2011 Apr; 6(2):025012. PubMed ID: 21441653
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Density functional theory simulation of titanium migration and reaction with oxygen in the early stages of oxidation of equiatomic NiTi alloy.
    Nolan M; Tofail SA
    Biomaterials; 2010 May; 31(13):3439-48. PubMed ID: 20144474
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Effect of heat treatment on cyclic fatigue resistance, thermal behavior and microstructures of K3 NiTi rotary instruments.
    Chang SW; Kim YC; Chang H; Jee KK; Zhu Q; Safavi K; Shon WJ; Bae KS; Spangberg LS; Kum KY
    Acta Odontol Scand; 2013 Nov; 71(6):1656-62. PubMed ID: 23668244
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Effect of heat sterilization on surface characteristics and microstructure of Mani NRT rotary nickel-titanium instruments.
    Alexandrou G; Chrissafis K; Vasiliadis L; Pavlidou E; Polychroniadis EK
    Int Endod J; 2006 Oct; 39(10):770-8. PubMed ID: 16948662
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Instruments after Immersion in Sodium Hypochlorite and/or Sterilization.
    Pedullà E; Benites A; La Rosa GM; Plotino G; Grande NM; Rapisarda E; Generali L
    J Endod; 2018 Apr; 44(4):648-653. PubMed ID: 29397218
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Evaluation of surface alterations in different retreatment nickel-titanium files: AFM and SEM study.
    Can Sağlam B; Görgül G
    Microsc Res Tech; 2015 May; 78(5):356-62. PubMed ID: 25736462
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Are more nickel ions released from NiTi wires after sterilisation?
    Poosti M; Rad HP; Kianoush K; Hadizadeh B
    Aust Orthod J; 2009 May; 25(1):30-3. PubMed ID: 19634461
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments.
    Braga LC; Faria Silva AC; Buono VT; de Azevedo Bahia MG
    J Endod; 2014 Sep; 40(9):1494-7. PubMed ID: 25146041
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
    Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
    Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.