These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

242 related articles for article (PubMed ID: 10561646)

  • 1. Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia.
    Natarajan P; Shennan AH; Penny J; Halligan AW; de Swiet M; Anthony J
    Am J Obstet Gynecol; 1999 Nov; 181(5 Pt 1):1203-10. PubMed ID: 10561646
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of automated home blood pressure monitoring in pregnancy: is it safe?
    Lo C; Taylor RS; Gamble G; McCowan L; North RA
    Am J Obstet Gynecol; 2002 Nov; 187(5):1321-8. PubMed ID: 12439526
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automated blood pressure measurement devices: a potential source of morbidity in preeclampsia?
    Quinn M
    Am J Obstet Gynecol; 1994 May; 170(5 Pt 1):1303-7. PubMed ID: 8178857
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the Schiller BR-102 ambulatory blood pressure system according to the protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation.
    O'Brien E; Mee F; Atkins N
    Blood Press Monit; 1999 Feb; 4(1):35-43. PubMed ID: 10362889
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of the Welch Allyn 'Vital Signs' blood pressure measurement device in pregnancy and pre-eclampsia.
    Reinders A; Cuckson AC; Jones CR; Poet R; O'Sullivan G; Shennan AH
    BJOG; 2003 Feb; 110(2):134-8. PubMed ID: 12618156
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the oscillometric blood pressure monitor (BPM-100(Beta) ) with the auscultatory mercury sphygmomanometer.
    Mattu GS; Perry TL; Wright JM
    Blood Press Monit; 2001 Jun; 6(3):153-9. PubMed ID: 11518839
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparisons of auscultatory hybrid and automated sphygmomanometers with mercury sphygmomanometry in hypertensive and normotensive pregnant women: parallel validation studies.
    Davis GK; Roberts LM; Mangos GJ; Brown MA
    J Hypertens; 2015 Mar; 33(3):499-505; discussion 505-6. PubMed ID: 25380148
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro and in vivo evaluation of an oscillometric device for monitoring blood pressure in dialysis patients.
    Lodi CA; Estridge C; Ghidini C
    Nephrol Dial Transplant; 2007 Oct; 22(10):2950-61. PubMed ID: 17556423
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of oscillometric blood pressure monitoring in pregnancy and pre-eclampsia.
    Gupta M; Shennan AH; Halligan A; Taylor DJ; de Swiet M
    Br J Obstet Gynaecol; 1997 Mar; 104(3):350-5. PubMed ID: 9091015
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of the shapes of the oscillometric pulse amplitude envelopes and their characteristic ratios on the differences between auscultatory and oscillometric blood pressure measurements.
    Amoore JN; Vacher E; Murray IC; Mieke S; King ST; Smith FE; Murray A
    Blood Press Monit; 2007 Oct; 12(5):297-305. PubMed ID: 17890968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wrist blood pressure-measuring devices: a comparative study of accuracy with a standard auscultatory method using a mercury manometer.
    Altunkan S; Yildiz S; Azer S
    Blood Press Monit; 2002 Oct; 7(5):281-4. PubMed ID: 12409888
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy.
    Thompson AM; Eguchi K; Reznik ME; Shah SS; Pickering TG
    Blood Press Monit; 2007 Aug; 12(4):227-32. PubMed ID: 17625395
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical evaluation of an automated oscillometric blood pressure wrist device.
    Cuckson AC; Moran P; Seed P; Reinders A; Shennan AH
    Blood Press Monit; 2004 Feb; 9(1):31-7. PubMed ID: 15021076
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An Assessment of the Accuracy of Home Blood Pressure Monitors When Used in Device Owners.
    Ringrose JS; Polley G; McLean D; Thompson A; Morales F; Padwal R
    Am J Hypertens; 2017 Jul; 30(7):683-689. PubMed ID: 28430848
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the automated non-invasive oscillometric blood pressure monitor (BpTRU) with the auscultatory mercury sphygmomanometer in a paediatric population.
    Mattu GS; Heran BS; Wright JM
    Blood Press Monit; 2004 Feb; 9(1):39-45. PubMed ID: 15021077
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inflationary oscillometry provides accurate measurement of blood pressure in pre-eclampsia.
    Golara M; Benedict A; Jones C; Randhawa M; Poston L; Shennan AH
    BJOG; 2002 Oct; 109(10):1143-7. PubMed ID: 12387468
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A perfect replacement for the mercury sphygmomanometer: the case of the hybrid blood pressure monitor.
    Stergiou GS; Karpettas N; Kollias A; Destounis A; Tzamouranis D
    J Hum Hypertens; 2012 Apr; 26(4):220-7. PubMed ID: 21900952
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of oscillometric blood pressure monitoring with concurrent auscultatory blood pressure in hemodialysis patients.
    Semret M; Zidehsarai M; Agarwal R
    Blood Press Monit; 2005 Oct; 10(5):249-55. PubMed ID: 16205443
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The relative accuracy of sequential same-arm and simultaneous opposite-arm measurements for the intra-arterial validation of blood pressure monitors.
    Penny JA; Shennan AH; Halligan AW; Taylor DJ; de Swiet M; Anthony J
    Blood Press Monit; 1999 Apr; 4(2):91-5. PubMed ID: 10450119
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ambulatory blood pressure in pregnancy: comparison of the Spacelabs 90207 and Accutracker II monitors with intraarterial recordings.
    Brown MA; Buddle ML; Bennett M; Smith B; Morris R; Whitworth JA
    Am J Obstet Gynecol; 1995 Jul; 173(1):218-23. PubMed ID: 7631686
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.