These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
202 related articles for article (PubMed ID: 10566211)
1. [A negative interference effect of pathologic levels of bilirubin on the determination of serum creatinine]. Smrcková I; Charvát J; Malá D; Lácha J Cas Lek Cesk; 1999 Jun; 138(13):406-8. PubMed ID: 10566211 [TBL] [Abstract][Full Text] [Related]
2. Extent of bilirubin interference with Beckman creatinine methods. Dimeski G; McWhinney B; Jones B; Mason R; Carter A Ann Clin Biochem; 2008 Jan; 45(Pt 1):91-2. PubMed ID: 18275681 [TBL] [Abstract][Full Text] [Related]
3. Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine. Hermida FJ; Lorenzo MJ; Pérez A; Fernández M; Sagastagoia O; Magadán C Scand J Clin Lab Invest; 2014 Oct; 74(7):629-36. PubMed ID: 24988313 [TBL] [Abstract][Full Text] [Related]
4. Serum ultrafiltration for the elimination of endogenous interfering substances in creatinine determination. da Fonseca-Wollheim F; Heinze KG; Lomsky K; Schreiner H J Clin Chem Clin Biochem; 1988 Aug; 26(8):523-5. PubMed ID: 3221182 [TBL] [Abstract][Full Text] [Related]
5. [Evaluation of kidney function in patients before and after orthotopic liver transplantation]. Hrncárková H; Schück O; Malý J; Trunecka P; Spicák J Vnitr Lek; 2000 Feb; 46(2):102-6. PubMed ID: 11048532 [TBL] [Abstract][Full Text] [Related]
6. [Elimination of bilirubin interference on creatinine determination (kinetic Jaffé method) using bilirubin oxidase]. Matsushita M; Maehata E; Aoki Y Rinsho Byori; 1986 Jun; 34(6):694-8. PubMed ID: 3747210 [No Abstract] [Full Text] [Related]
7. Coronary artery bypass grafting in non-dialysis-dependent mild-to-moderate renal dysfunction. Weerasinghe A; Hornick P; Smith P; Taylor K; Ratnatunga C J Thorac Cardiovasc Surg; 2001 Jun; 121(6):1083-9. PubMed ID: 11385375 [TBL] [Abstract][Full Text] [Related]
8. A study of interferences in routine methods for creatinine measurement. Kenny D Scand J Clin Lab Invest Suppl; 1993; 212():43-7. PubMed ID: 8465153 [TBL] [Abstract][Full Text] [Related]
9. Serum creatinine and bilirubin predict renal failure and mortality in patients with spontaneous bacterial peritonitis: a retrospective study. Terg R; Gadano A; Cartier M; Casciato P; Lucero R; Muñoz A; Romero G; Levi D; Terg G; Miguez C; Abecasis R Liver Int; 2009 Mar; 29(3):415-9. PubMed ID: 18803587 [TBL] [Abstract][Full Text] [Related]
10. Interference of selected second- and third-generation cephalosporins with creatinine determination. Guay DR; Meatherall RC; Macaulay PA Am J Hosp Pharm; 1983 Mar; 40(3):435-8. PubMed ID: 6846351 [TBL] [Abstract][Full Text] [Related]
11. Oxidation markedly reduces bilirubin interference in the Jaffé creatinine assay. Rajs G; Mayer M Clin Chem; 1992 Dec; 38(12):2411-3. PubMed ID: 1333917 [TBL] [Abstract][Full Text] [Related]
12. Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods. Owen LJ; Wear JE; Keevil BG Ann Clin Biochem; 2006 Mar; 43(Pt 2):118-23. PubMed ID: 16536913 [TBL] [Abstract][Full Text] [Related]
13. Interference of cephalosporins and cefoxitin with serum creatinine determination. Hyneck ML; Berardi RR; Johnson RM Am J Hosp Pharm; 1981 Sep; 38(9):1348-52. PubMed ID: 7282720 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of hemoglobin interference in capillary heel-stick samples collected for determination of neonatal bilirubin. Algeciras-Schimnich A; Cook WJ; Milz TC; Saenger AK; Karon BS Clin Biochem; 2007 Nov; 40(16-17):1311-6. PubMed ID: 17825810 [TBL] [Abstract][Full Text] [Related]
15. Multicentre evaluation of an enzymatic method for creatinine determination using a sensitive colour reagent. Guder WG; Hoffmann GE; Hubbuch A; Poppe WA; Siedel J; Price CP J Clin Chem Clin Biochem; 1986 Nov; 24(11):889-902. PubMed ID: 3806017 [TBL] [Abstract][Full Text] [Related]
16. Clinical value of increased serum creatinine concentration as predictor of short-term outcome in decompensated cirrhosis. Serra MA; Puchades MJ; Rodríguez F; Escudero A; del Olmo JA; Wassel AH; Rodrigo JM Scand J Gastroenterol; 2004 Nov; 39(11):1149-53. PubMed ID: 15545175 [TBL] [Abstract][Full Text] [Related]
17. On the accuracy of the Reflotron creatinine determination. Blijenberg BG; Liesting EC; Zwang L Eur J Clin Chem Clin Biochem; 1992 Jan; 30(1):51-3. PubMed ID: 1576242 [TBL] [Abstract][Full Text] [Related]
18. Bilirubin and metamizol do not interfere with the randox enzymatic creatinine test. An evaluation of a new enzymatic creatinine determination method. Harmoinen AP Eur J Clin Chem Clin Biochem; 1996 Dec; 34(12):975-6. PubMed ID: 8986403 [TBL] [Abstract][Full Text] [Related]
19. Investigations into negative interference by jaundiced plasma in kinetic Jaffé methods for plasma creatinine determination. Knapp ML; Hadid O Ann Clin Biochem; 1987 Jan; 24 ( Pt 1)():85-97. PubMed ID: 3827191 [TBL] [Abstract][Full Text] [Related]
20. Comparison of techniques for minimizing interference of bilirubin on serum creatinine determined by the kinetic Jaffé reaction. Lolekha PH; Sritong N J Clin Lab Anal; 1994; 8(6):391-9. PubMed ID: 7869178 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]