These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 10571900)

  • 21. In vitro wear simulation on the RandomPOD wear testing system as a screening method for bearing materials intended for total knee arthroplasty.
    Saikko V
    J Biomech; 2014 Aug; 47(11):2774-8. PubMed ID: 24835561
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant.
    Bigsby RJ; Hardaker CS; Fisher J
    Proc Inst Mech Eng H; 1997; 211(3):265-9. PubMed ID: 9256003
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2001 Dec; 57(4):506-12. PubMed ID: 11553880
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study.
    McKellop H; Shen FW; Lu B; Campbell P; Salovey R
    J Bone Joint Surg Am; 2000 Dec; 82(12):1708-25. PubMed ID: 11130644
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure.
    Kang L; Galvin AL; Brown TD; Fisher J; Jin ZM
    Proc Inst Mech Eng H; 2008 Oct; 222(7):1049-64. PubMed ID: 19024153
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res B Appl Biomater; 2004 May; 69(2):141-8. PubMed ID: 15116403
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
    Kang L; Galvin AL; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
    Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
    J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The effect of roughness on the tribological behavior of the prosthetic pair UHMWPE/TiN-coated stainless steel.
    Gispert MP; Serro AP; Colaço R; Pires E; Saramago B
    J Biomed Mater Res B Appl Biomater; 2008 Jan; 84(1):98-107. PubMed ID: 17455280
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy.
    Kumar P; Oka M; Ikeuchi K; Shimizu K; Yamamuro T; Okumura H; Kotoura Y
    J Biomed Mater Res; 1991 Jul; 25(7):813-28. PubMed ID: 1918102
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The wear of cross-linked polyethylene against itself.
    Joyce TJ; Ash HE; Unsworth A
    Proc Inst Mech Eng H; 1996; 210(1):11-6. PubMed ID: 8663888
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Statistical analysis of VEXLPE wear against alumina produced by a new 200-station, multidirectional pin-on-disk device.
    Saikko V
    Proc Inst Mech Eng H; 2024 Apr; 238(4):438-443. PubMed ID: 38439747
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator.
    Smith SL; Unsworth A
    Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Frictional heating of bearing materials tested in a hip joint wear simulator.
    Lu Z; McKellop H
    Proc Inst Mech Eng H; 1997; 211(1):101-8. PubMed ID: 9141895
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene.
    Abdelgaied A; Brockett CL; Liu F; Jennings LM; Fisher J; Jin Z
    Proc Inst Mech Eng H; 2013 Jan; 227(1):18-26. PubMed ID: 23516952
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.
    Korduba LA; Essner A; Pivec R; Lancin P; Mont MA; Wang A; Delanois RE
    Am J Orthop (Belle Mead NJ); 2014 Oct; 43(10):466-71. PubMed ID: 25303445
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of the sterilisation method on the wear of UHMWPE acetabular cups tested in a hip joint simulator.
    Affatato S; Bordini B; Fagnano C; Taddei P; Tinti A; Toni A
    Biomaterials; 2002 Mar; 23(6):1439-46. PubMed ID: 11829439
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Wear studies of all UHMWPE couples under various bio-tribological conditions.
    Joyce TJ; Unsworth A
    J Appl Biomater Biomech; 2004; 2(1):29-34. PubMed ID: 20803448
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Tribological characteristics of polyethylene glycol (PEG) as a lubricant for wear resistance of ultra-high-molecular-weight polyethylene (UHMWPE ) in artificial knee join.
    Kobayashi M; Koide T; Hyon SH
    J Mech Behav Biomed Mater; 2014 Oct; 38():33-8. PubMed ID: 25016174
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Al-Cu-Fe quasicrystal/ultra-high molecular weight polyethylene composites as biomaterials for acetabular cup prosthetics.
    Anderson BC; Bloom PD; Baikerikar KG; Sheares VV; Mallapragada SK
    Biomaterials; 2002 Apr; 23(8):1761-8. PubMed ID: 11950046
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.