278 related articles for article (PubMed ID: 10571928)
1. On standardizing the MR image intensity scale.
Nyúl LG; Udupa JK
Magn Reson Med; 1999 Dec; 42(6):1072-81. PubMed ID: 10571928
[TBL] [Abstract][Full Text] [Related]
2. New variants of a method of MRI scale standardization.
Nyúl LG; Udupa JK; Zhang X
IEEE Trans Med Imaging; 2000 Feb; 19(2):143-50. PubMed ID: 10784285
[TBL] [Abstract][Full Text] [Related]
3. Numerical tissue characterization in MS via standardization of the MR image intensity scale.
Ge Y; Udupa JK; Nyúl LG; Wei L; Grossman RI
J Magn Reson Imaging; 2000 Nov; 12(5):715-21. PubMed ID: 11050641
[TBL] [Abstract][Full Text] [Related]
4. Comparing MR image intensity standardization against tissue characterizability of magnetization transfer ratio imaging.
Madabhushi A; Udupa JK; Moonis G
J Magn Reson Imaging; 2006 Sep; 24(3):667-75. PubMed ID: 16878312
[TBL] [Abstract][Full Text] [Related]
5. Histogram-based normalization technique on human brain magnetic resonance images from different acquisitions.
Sun X; Shi L; Luo Y; Yang W; Li H; Liang P; Li K; Mok VCT; Chu WCW; Wang D
Biomed Eng Online; 2015 Jul; 14():73. PubMed ID: 26215471
[TBL] [Abstract][Full Text] [Related]
6. Robust Intensity Standardization in Brain Magnetic Resonance Images.
De Nunzio G; Cataldo R; Carlà A
J Digit Imaging; 2015 Dec; 28(6):727-37. PubMed ID: 25708893
[TBL] [Abstract][Full Text] [Related]
7. New methods of MR image intensity standardization via generalized scale.
Madabhushi A; Udupa JK
Med Phys; 2006 Sep; 33(9):3426-34. PubMed ID: 17022239
[TBL] [Abstract][Full Text] [Related]
8. Interplay between intensity standardization and inhomogeneity correction in MR image processing.
Madabhushi A; Udupa JK
IEEE Trans Med Imaging; 2005 May; 24(5):561-76. PubMed ID: 15889544
[TBL] [Abstract][Full Text] [Related]
9. Nonrigid registration of joint histograms for intensity standardization in magnetic resonance imaging.
Jäger F; Hornegger J
IEEE Trans Med Imaging; 2009 Jan; 28(1):137-50. PubMed ID: 19116196
[TBL] [Abstract][Full Text] [Related]
10. Evaluating intensity normalization on MRIs of human brain with multiple sclerosis.
Shah M; Xiao Y; Subbanna N; Francis S; Arnold DL; Collins DL; Arbel T
Med Image Anal; 2011 Apr; 15(2):267-82. PubMed ID: 21233004
[TBL] [Abstract][Full Text] [Related]
11. A segmentation of brain MRI images utilizing intensity and contextual information by Markov random field.
Chen M; Yan Q; Qin M
Comput Assist Surg (Abingdon); 2017 Dec; 22(sup1):200-211. PubMed ID: 29072503
[TBL] [Abstract][Full Text] [Related]
12. Quantitative MRI studies for assessment of multiple sclerosis.
Pannizzo F; Stallmeyer MJ; Friedman J; Jennis RJ; Zabriskie J; Plank C; Zimmerman R; Whalen JP; Cahill PT
Magn Reson Med; 1992 Mar; 24(1):90-9. PubMed ID: 1556933
[TBL] [Abstract][Full Text] [Related]
13. Standardized magnetic resonance imaging acquisition and reporting in pediatric multiple sclerosis.
Verhey LH; Narayanan S; Banwell B
Neuroimaging Clin N Am; 2013 May; 23(2):217-26.e1-7. PubMed ID: 23608686
[TBL] [Abstract][Full Text] [Related]
14. An energy minimization method for MS lesion segmentation from T1-w and FLAIR images.
Zhao Y; Guo S; Luo M; Liu Y; Bilello M; Li C
Magn Reson Imaging; 2017 Jun; 39():1-6. PubMed ID: 27343952
[TBL] [Abstract][Full Text] [Related]
15. Learning-based 3T brain MRI segmentation with guidance from 7T MRI labeling.
Deng M; Yu R; Wang L; Shi F; Yap PT; Shen D;
Med Phys; 2016 Dec; 43(12):6588-6597. PubMed ID: 28054724
[TBL] [Abstract][Full Text] [Related]
16. Stratified mixture modeling for segmentation of white-matter lesions in brain MR images.
Galimzianova A; Pernuš F; Likar B; Špiclin Ž
Neuroimage; 2016 Jan; 124(Pt A):1031-1043. PubMed ID: 26427644
[TBL] [Abstract][Full Text] [Related]
17. Correction for variations in MRI scanner sensitivity in brain studies with histogram matching.
Wang L; Lai HM; Barker GJ; Miller DH; Tofts PS
Magn Reson Med; 1998 Feb; 39(2):322-7. PubMed ID: 9469718
[TBL] [Abstract][Full Text] [Related]
18. A level set method for multiple sclerosis lesion segmentation.
Zhao Y; Guo S; Luo M; Shi X; Bilello M; Zhang S; Li C
Magn Reson Imaging; 2018 Jun; 49():94-100. PubMed ID: 28522366
[TBL] [Abstract][Full Text] [Related]
19. MRI intensity inhomogeneity correction by combining intensity and spatial information.
Vovk U; Pernus F; Likar B
Phys Med Biol; 2004 Sep; 49(17):4119-33. PubMed ID: 15470927
[TBL] [Abstract][Full Text] [Related]
20. Robust generative asymmetric GMM for brain MR image segmentation.
Ji Z; Xia Y; Zheng Y
Comput Methods Programs Biomed; 2017 Nov; 151():123-138. PubMed ID: 28946994
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]