  • 1. Re: Baur & Butler. Electrocautery-ignited endotracheal tube fire: case report.
    Hardee P
    Br J Oral Maxillofac Surg; 1999 Oct; 37(5):422. PubMed ID: 10577760
    [No Abstract]   [Full Text] [Related]  

  • 2. Electrocautery-ignited endotracheal tube fire: case report.
    Baur DA; Butler RC
    Br J Oral Maxillofac Surg; 1999 Apr; 37(2):142-3. PubMed ID: 10371323
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Burning endotracheal tube. A complication of tracheotomy using electrocautery].
    Comberg G; Elfeldt R; Jeckström W; Wulf H
    Chirurg; 1995 Sep; 66(9):927-8. PubMed ID: 7587570
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Endotracheal tube fire induced by electrocautery during tracheostomy--a case report.
    Wu CC; Shen CH; Ho WM
    Acta Anaesthesiol Sin; 2002 Dec; 40(4):209-13. PubMed ID: 12596621
    [TBL] [Abstract][Full Text] [Related]  

  • 5. DuraPrep and the risk of fire during tracheostomy.
    Weber SM; Hargunani CA; Wax MK
    Head Neck; 2006 Jul; 28(7):649-52. PubMed ID: 16691556
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Endotracheal tube cuff ignited by electrocautery during tracheostomy.
    Le Clair J; Gartner S; Halma G
    AANA J; 1990 Aug; 58(4):259-61. PubMed ID: 2399778
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Orotracheal tube ignited by an electrocautery device during tracheostomy].
    Villarroya González A; Longás Valién J; Vicente Armijo JJ; Cuartero Lobera J
    Rev Esp Anestesiol Reanim; 2009 Jan; 56(1):47-9. PubMed ID: 19284128
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Airway fire during electrocautery dissection of the tonsils].
    Guzmán Malpica EM; Rufino Ruiz J; Rivas Castro M; Galán Ortega M; Vidal Casas M; Cortés Sánchez R
    Rev Esp Anestesiol Reanim; 2005 Dec; 52(10):637-8. PubMed ID: 16435621
    [No Abstract]   [Full Text] [Related]  

  • 9. Endotracheal tube ignition by electrocautery during tracheostomy: case report with autopsy findings.
    Lew EO; Mittleman RE; Murray D
    J Forensic Sci; 1991 Sep; 36(5):1586-91. PubMed ID: 1955844
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endotracheal tube fire during tracheostomy: a case report.
    Awan MS; Ahmed I
    Ear Nose Throat J; 2002 Feb; 81(2):90-2. PubMed ID: 11868480
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Igniting the endotracheal tube in tracheotomy with electrocautery. How it should not be done].
    Albegger KW
    HNO; 1996 May; 44(5):271. PubMed ID: 8707634
    [No Abstract]   [Full Text] [Related]  

  • 12. [A case in which the endotracheal tube was ignited by an electrocautery during tracheotomy].
    Nakasuji M; Tsujimura S; Nakaochi T; Enomoto K; Sato Y
    Masui; 1995 Oct; 44(10):1381-3. PubMed ID: 8538008
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Endotracheal tube fire ignited by pharyngeal electrocautery.
    Simpson JI; Wolf GL
    Anesthesiology; 1986 Jul; 65(1):76-7. PubMed ID: 3729060
    [No Abstract]   [Full Text] [Related]  

  • 14. Endotracheal tube safety during electrodissection tonsillectomy.
    Keller C; Elliott W; Hubbell RN
    Arch Otolaryngol Head Neck Surg; 1992 Jun; 118(6):643-5. PubMed ID: 1637542
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endotracheal tube fires during carbon dioxide laser surgery on the larynx--a case report.
    Kuo CH; Tan PH; Chen JJ; Peng CH; Lee CC; Chung HC; Tseng CK
    Acta Anaesthesiol Sin; 2001 Mar; 39(1):53-6. PubMed ID: 11407297
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tracheostomy tube ignition during microlaryngeal surgery using diode laser: a case report.
    Wang HM; Lee KW; Tsai CJ; Lu IC; Kuo WR
    Kaohsiung J Med Sci; 2006 Apr; 22(4):199-202. PubMed ID: 16679303
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fatal inhalation injury caused by airway fire during tracheostomy.
    Niskanen M; Purhonen S; Koljonen V; Ronkainen A; Hirvonen E
    Acta Anaesthesiol Scand; 2007 Apr; 51(4):509-13. PubMed ID: 17378792
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Injuries to the bronchi and lungs caused by laser-ignited endotracheal tube fires.
    Duncavage JA; Ossoff RH; Rouman WC; Toohill RJ; Almagro UA; Carl GA; Aronson S
    Otolaryngol Head Neck Surg; 1984 Dec; 92(6):639-43. PubMed ID: 6440081
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Obstruction of an reinforced endotracheal tube due to dissection of internal tube wall during total intravenous anesthesia].
    Tose R; Kubota T; Hirota K; Sakai T; Ishihara H; Matsuki A
    Masui; 2003 Nov; 52(11):1218-20. PubMed ID: 14661571
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Obstruction of the left upper lobar bronchus by a double-lumen endotracheal tube. Apropos of a case].
    Pueyo JA; Fuentes R; Bustos A; Guerrero MI; Torres LM
    Rev Esp Anestesiol Reanim; 1992; 39(2):134. PubMed ID: 1594783
    [No Abstract]   [Full Text] [Related]  