BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 10582977)

  • 1. Measurement of hemostatic indexes in conjunction with transcranial doppler sonography in patients with ventricular assist devices.
    Wilhelm CR; Ristich J; Knepper LE; Holubkov R; Wisniewski SR; Kormos RL; Wagner WR
    Stroke; 1999 Dec; 30(12):2554-61. PubMed ID: 10582977
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cerebral Microembolization in Left Ventricular Assist Device Associated Ischemic Events.
    Hassett CE; Cho SM; Rice CJ; Migdady I; Starling RC; Uchino K; Katzan IL
    J Stroke Cerebrovasc Dis; 2020 Apr; 29(4):104660. PubMed ID: 32044219
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mechanisms of cerebrovascular events as assessed by procoagulant activity, cerebral microemboli, and platelet microparticles in patients with prosthetic heart valves.
    Geiser T; Sturzenegger M; Genewein U; Haeberli A; Beer JH
    Stroke; 1998 Sep; 29(9):1770-7. PubMed ID: 9731593
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Activation of coagulation and fibrinolytic pathways in patients with left ventricular assist devices.
    Spanier T; Oz M; Levin H; Weinberg A; Stamatis K; Stern D; Rose E; Schmidt AM
    J Thorac Cardiovasc Surg; 1996 Oct; 112(4):1090-7. PubMed ID: 8873737
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Increased activation of the coagulation and fibrinolytic systems leads to hemorrhagic complications during left ventricular assist implantation.
    Livingston ER; Fisher CA; Bibidakis EJ; Pathak AS; Todd BA; Furukawa S; McClurken JB; Addonizio VP; Jeevanandam V
    Circulation; 1996 Nov; 94(9 Suppl):II227-34. PubMed ID: 8901751
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monocyte tissue factor expression and ongoing complement generation in ventricular assist device patients.
    Wilhelm CR; Ristich J; Kormos RL; Wagner WR
    Ann Thorac Surg; 1998 Apr; 65(4):1071-6. PubMed ID: 9564930
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of micro-emboli in a patient with ventricular assist device support with hemolysis.
    Seguchi O; Saito K; Fukuma K; Shimamoto K; Sato T; Nakajima S; Sunami H; Kuroda K; Sato T; Watanabe T; Hata H; Yanase M; Fujita T; Kobayashi J; Nagatsuka K; Nakatani T
    J Artif Organs; 2015 Sep; 18(3):276-9. PubMed ID: 25796205
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Countable and non-countable microembolic signals by TCD in first-ever stroke or TIA patients with PFO.
    Telman G; Kouperberg E; Sprecher E; Yarnitsky D
    J Neurol Sci; 2008 May; 268(1-2):83-6. PubMed ID: 18076907
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of prothrombin activation during cardiac surgery by hemostatic molecular markers.
    Slaughter TF; LeBleu TH; Douglas JM; Leslie JB; Parker JK; Greenberg CS
    Anesthesiology; 1994 Mar; 80(3):520-6. PubMed ID: 8141448
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical relevance of intracranial microembolic signals in patients with left ventricular assist devices. A prospective study.
    Nabavi DG; Georgiadis D; Mumme T; Schmid C; Mackay TG; Scheld HH; Ringelstein EB
    Stroke; 1996 May; 27(5):891-6. PubMed ID: 8623109
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Association between prothrombin activation fragment (F1.2), cerebral ischemia (S-100beta) and international normalized ratio (INR) in patients with ventricular assisted devices.
    Joshi A; Magder LS; Kon Z; Kallam S; Kwon M; Sangrampurkar R; Pierson R; Poston R
    Interact Cardiovasc Thorac Surg; 2007 Jun; 6(3):323-7. PubMed ID: 17669856
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transcranial detection of microembolic signals in patients with a novel nonpulsatile implantable LVAD.
    Potapov EV; Nasseri BA; Loebe M; Kukucka M; Koster A; Kuppe H; Noon GP; DeBakey ME; Hetzer R
    ASAIO J; 2001; 47(3):249-53. PubMed ID: 11374767
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microembolic signals on transcranial Doppler ultrasound are correlated with platelet activation markers, but not with platelet-leukocyte associates: a study in patients with acute stroke and in patients with asymptomatic carotid stenosis.
    Ritter MA; Jurk K; Schriek C; Nabavi DG; Droste DW; Kehrel BE; Bernd Ringelstein E
    Neurol Res; 2009 Feb; 31(1):11-6. PubMed ID: 18768115
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Thrombin production, inactivation and expression during open heart surgery measured by assays for activation fragments including a new ELISA for prothrombin fragment F1 + 2.
    Boisclair MD; Lane DA; Philippou H; Sheikh S; Hunt B
    Thromb Haemost; 1993 Aug; 70(2):253-8. PubMed ID: 8236130
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Role of factor XII in thrombin generation and fibrinolysis during cardiopulmonary bypass.
    Burman JF; Chung HI; Lane DA; Philippou H; Adami A; Lincoln JC
    Lancet; 1994 Oct; 344(8931):1192-3. PubMed ID: 7934541
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microembolic signal monitoring in patients with HeartMate 3 and HeartWare left ventricular assist devices: Association with antithrombotic treatment and cerebrovascular events.
    Ravenberg KK; Gabriel MM; Leotescu A; Tran AT; Grosse GM; Schuppner R; Ernst J; Lichtinghagen R; Tiede A; Werwitzke S; Bara CL; Schmitto JD; Weissenborn K; Hanke JS; Worthmann H
    Artif Organs; 2023 Feb; 47(2):370-379. PubMed ID: 36114791
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Association of the fibrinolytic system and hemorheology with symptoms in patients with carotid occlusive disease.
    Soinne L; Saimanen E; Malmberg-Céder K; Kovanen P; Lindsberg PJ; Kaste M; Lassila R
    Cerebrovasc Dis; 2005; 20(3):172-9. PubMed ID: 16088112
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Size of PFO and amount of microembolic signals in patients with ischaemic stroke or TIA.
    Telman G; Yalonetsky S; Kouperberg E; Sprecher E; Lorber A; Yarnitsky D
    Eur J Neurol; 2008 Sep; 15(9):969-72. PubMed ID: 18637824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thrombin generation and fibrinolysis in the thrombotic thrombocytopenic purpura and the hemolytic-uremic syndrome.
    Monteagudo J; Pereira A; Reverter JC; Pijoan J; Tusell J; Puig L; Ordinas A; Castillo R
    Thromb Haemost; 1991 Nov; 66(5):515-9. PubMed ID: 1803613
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cerebral and systemic embolization during left ventricular support with the Novacor N100 device.
    Schmid C; Weyand M; Nabavi DG; Hammel D; Deng MC; Ringelstein EB; Scheld HH
    Ann Thorac Surg; 1998 Jun; 65(6):1703-10. PubMed ID: 9647085
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.