These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 10587230)

  • 1. Spectra and air-kerma strength for encapsulated 192Ir sources.
    Borg J; Rogers DW
    Med Phys; 1999 Nov; 26(11):2441-4. PubMed ID: 10587230
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Study of encapsulated 170Tm sources for their potential use in brachytherapy.
    Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ
    Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo aided room scatter studies in the primary air kerma strength standardization of a remote afterloading 192Ir HDR source.
    Selvam TP; Rajan KN; Nagarajan PS; Sethulakshmi P; Bhatt BC
    Phys Med Biol; 2001 Sep; 46(9):2299-315. PubMed ID: 11580170
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy.
    Hiatt JR; Rivard MJ; Hughes HG
    Med Phys; 2016 Mar; 43(3):1119-29. PubMed ID: 26936699
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of source geometry and materials on the transverse axis dosimetry of 192Ir brachytherapy sources.
    Wang R; Sloboda RS
    Phys Med Biol; 1998 Jan; 43(1):37-48. PubMed ID: 9483622
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192Ir sources.
    Williamson JF; Li Z
    Med Phys; 1995 Jun; 22(6):809-19. PubMed ID: 7565372
    [TBL] [Abstract][Full Text] [Related]  

  • 7. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.
    Selvam TP; Sahoo S; Vishwakarma RS
    Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air.
    Rivard MJ; Granero D; Perez-Calatayud J; Ballester F
    Med Phys; 2010 Feb; 37(2):869-76. PubMed ID: 20229896
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons.
    Ballester F; Granero D; Pérez-Calatayud J; Melhus CS; Rivard MJ
    Med Phys; 2009 Sep; 36(9):4250-6. PubMed ID: 19810499
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Monte Carlo study of verification imaging in high dose rate brachytherapy.
    Sheikh-Bagheri D; Munro P
    Med Phys; 1998 Apr; 25(4):404-14. PubMed ID: 9571606
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo calculations of the ionization chamber wall correction factors for 192Ir and 60Co gamma rays and 250 kV x-rays for use in calibration of 192Ir HDR brachytherapy sources.
    Ferreira IH; de Almeida CE; Marre D; Marechal MH; Bridier A; Chavaudra J
    Phys Med Biol; 1999 Aug; 44(8):1897-904. PubMed ID: 10473203
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo dosimetry of the microselectron HDR 192Ir brachytherapy source using MCNP4A.
    Wallace S; Wong T; Fernando W
    Australas Phys Eng Sci Med; 1998 Mar; 21(1):11-7. PubMed ID: 9633148
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo dosimetry of the VariSource high dose rate 192Ir source.
    Wang R; Sloboda RS
    Med Phys; 1998 Apr; 25(4):415-23. PubMed ID: 9571607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.
    van Dijk E; Kolkman-Deurloo IK; Damen PM
    Med Phys; 2004 Oct; 31(10):2826-33. PubMed ID: 15543790
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.
    Austerlitz C; Mota HC; Sempau J; Benhabib SM; Campos D; Allison R; DeAlmeida CE; Zhu D; Sibata CH
    Med Phys; 2008 Dec; 35(12):5360-5. PubMed ID: 19175095
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo study of correction factors for Spencer-Attix cavity theory at photon energies at or above 100 keV.
    Borg J; Kawrakow I; Rogers DW; Seuntjens JP
    Med Phys; 2000 Aug; 27(8):1804-13. PubMed ID: 10984227
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of air-kerma strength for the 192Ir GammaMedplus iX pulsed-dose-rate brachytherapy source.
    Riley AD; Pike TL; Micka JA; Fulkerson RK; DeWerd LA
    Med Phys; 2013 Jul; 40(7):071732. PubMed ID: 23822436
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The IPEM code of practice for determination of the reference air kerma rate for HDR (192)Ir brachytherapy sources based on the NPL air kerma standard.
    Bidmead AM; Sander T; Locks SM; Lee CD; Aird EG; Nutbrown RF; Flynn A;
    Phys Med Biol; 2010 Jun; 55(11):3145-59. PubMed ID: 20479510
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of air kerma standards of LNE-LNHB and NPL for 192Ir HDR brachytherapy sources: EUROMET project no 814.
    Douysset G; Sander T; Gouriou J; Nutbrown R
    Phys Med Biol; 2008 Mar; 53(6):N85-97. PubMed ID: 18367784
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dose characterization in the near-source region for two high dose rate brachytherapy sources.
    Wang R; Li XA
    Med Phys; 2002 Aug; 29(8):1678-86. PubMed ID: 12201413
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.