BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 10587695)

  • 1. Analytic and clinical evaluation of the Abbott AxSYM cardiac troponin I assay.
    ver Elst KM; Chapelle JP; Boland P; Demolder JS; Gorus FK
    Am J Clin Pathol; 1999 Dec; 112(6):745-52. PubMed ID: 10587695
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multicenter clinical and analytical evaluation of the AxSYM troponin-I immunoassay to assist in the diagnosis of myocardial infarction.
    Apple FS; Maturen AJ; Mullins RE; Painter PC; Pessin-Minsley MS; Webster RA; Spray Flores J; DeCresce R; Fink DJ; Buckley PM; Marsh J; Ricchiuti V; Christenson RH
    Clin Chem; 1999 Feb; 45(2):206-12. PubMed ID: 9931042
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved identification of acute coronary syndromes with second generation cardiac troponin I assay: utility of 2-hour delta cTnI > or = +0.02 ng/mL.
    Fesmire FM; Fesmire CE
    J Emerg Med; 2002 Feb; 22(2):147-52. PubMed ID: 11858918
    [TBL] [Abstract][Full Text] [Related]  

  • 4. False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factors.
    Dasgupta A; Banerjee SK; Datta P
    Am J Clin Pathol; 1999 Dec; 112(6):753-6. PubMed ID: 10587696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiac troponin-T immunoassay for diagnosis of acute myocardial infarction.
    Wu AH; Valdes R; Apple FS; Gornet T; Stone MA; Mayfield-Stokes S; Ingersoll-Stroubos AM; Wiler B
    Clin Chem; 1994 Jun; 40(6):900-7. PubMed ID: 8087984
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiac troponin I measurement with the ACCESS immunoassay system: analytical and clinical performance characteristics.
    Christenson RH; Apple FS; Morgan DL; Alonsozana GL; Mascotti K; Olson M; McCormack RT; Wians FH; Keffer JH; Duh SH
    Clin Chem; 1998 Jan; 44(1):52-60. PubMed ID: 9550558
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the analytical performance of the advanced method for cardiac troponin I for the AxSYM platform: comparison with the old method and the Access system.
    Storti S; Prontera C; Parri MS; Iervasi A; Vittorini S; Emdin M; Zucchelli GC; Longombardo G; Migliorini P; Clerico A
    Clin Chem Lab Med; 2006; 44(8):1022-9. PubMed ID: 16879072
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analytical performance and clinical utility of a sensitive immunoassay for determination of human cardiac troponin I.
    Davies E; Gawad Y; Takahashi M; Shi Q; Lam P; Styba G; Lau A; Heeschen C; Usategui M; Jackowski G
    Clin Biochem; 1997 Aug; 30(6):479-90. PubMed ID: 9316743
    [TBL] [Abstract][Full Text] [Related]  

  • 9. False-positive troponin I measured with the Abbott AxSYM attributed to fibrin interference.
    Kazmierczak SC; Sekhon H; Richards C
    Int J Cardiol; 2005 May; 101(1):27-31. PubMed ID: 15860379
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of monoclonal antibodies for an assay of cardiac troponin-I and preliminary results in suspected cases of myocardial infarction.
    Bodor GS; Porter S; Landt Y; Ladenson JH
    Clin Chem; 1992 Nov; 38(11):2203-14. PubMed ID: 1424112
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Serum levels of cardiac troponin I and other marker proteins in patients with chronic renal failure.
    Nakai K; Nakai K; Nagane Y; Obara W; Sato M; Ohi K; Matsumoto N; Takanashi N; Itoh C
    Clin Exp Nephrol; 2004 Mar; 8(1):43-7. PubMed ID: 15067515
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of Abbott AxSYM, Behring Opus Plus, DPC Immulite and Ortho-Clinical Diagnostics Vitros ECi for measurement of cardiac troponin I.
    Kao JT; Wong IL; Lee JY; Chen RC
    Ann Clin Biochem; 2001 Mar; 38(Pt 2):140-6. PubMed ID: 11269755
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of elevated concentration of alkaline phosphatase on cardiac troponin I assays.
    Dasgupta A; Chow L; Wells A; Datta P
    J Clin Lab Anal; 2001; 15(4):175-7. PubMed ID: 11436198
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of Stratus CS stat fluorimetric analyser for measurement of cardiac markers Troponin I (cTnI), creatine kinase MB (CK-MB), and myoglobin.
    Bénéteau-Burnat B; Baudin B; Vaubourdolle M
    J Clin Lab Anal; 2001; 15(6):314-8. PubMed ID: 11793431
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies.
    Yeo KT; Storm CA; Li Y; Jayne JE; Brough T; Quinn-Hall KS; Fitzmaurice TF
    Clin Chim Acta; 2000 Feb; 292(1-2):13-23. PubMed ID: 10686273
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of kryptor cardiac troponin I immunoassay.
    Lefèvre G; Graïne H; Bakkouch K; Garbarz E; Marlin G; Michel PL; Capeau J
    Ann Clin Biochem; 2002 Mar; 39(Pt 2):145-7. PubMed ID: 11928763
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical performance of time-resolved fluorometry-based Innotrac Aio! cardiac marker immunoassays.
    Hedberg P; Valkama J; Puukka M
    Scand J Clin Lab Invest; 2003; 63(1):55-64. PubMed ID: 12729070
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical and analytical performance of automated immunochemiluminometric assays for determination of cardiac markers in serum.
    Panteghini M
    J Biolumin Chemilumin; 1998; 13(5):307-9. PubMed ID: 9839196
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of the troponin standard on the prevalence of acute myocardial infarction.
    Kontos MC; Fritz LM; Anderson FP; Tatum JL; Ornato JP; Jesse RL
    Am Heart J; 2003 Sep; 146(3):446-52. PubMed ID: 12947361
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of cardiac troponin I versus T and creatine kinase MB after coronary artery bypass grafting in patients with and without perioperative myocardial infarction.
    Peivandi AA; Dahm M; Opfermann UT; Peetz D; Doerr F; Loos A; Oelert H
    Herz; 2004 Nov; 29(7):658-64. PubMed ID: 15580320
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.