BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 10592751)

  • 1. [Paroxysmal nocturnal hemoglobinuria--diagnosis with the help of flow cytometry].
    Vetlesen A; Kjeldsen-Kragh J; Tjonnfjord GE
    Tidsskr Nor Laegeforen; 1999 Oct; 119(26):3909-13. PubMed ID: 10592751
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnosis of paroxysmal nocturnal haemoglobinuria by phenotypic analysis of erythrocytes using two-colour flow cytometry with monoclonal antibodies to DAF and CD59/MACIF.
    Shichishima T; Terasawa T; Saitoh Y; Hashimoto C; Ohto H; Maruyama Y
    Br J Haematol; 1993 Oct; 85(2):378-86. PubMed ID: 7506570
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow cytometric analysis of CD55 and CD59 expression on blood cells in paroxysmal nocturnal haemoglobinuria.
    Dworacki G; Sikora J; Mizera-Nyczak E; Trybus M; Mozer-Lisewska I; Czyz A; Zeromski J
    Folia Histochem Cytobiol; 2005; 43(2):117-20. PubMed ID: 16044949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flow cytometric analysis of erythrocytes in paroxysmal nocturnal hemoglobinuria reveals superiority of CD59 as a diagnostic marker compared to CD55.
    Tembhare P; Ramani M; Syed K; Gupta AD
    Indian J Pathol Microbiol; 2010; 53(4):699-703. PubMed ID: 21045396
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New monoclonal antibodies in CD59: use for the analysis of peripheral blood cells from paroxysmal nocturnal haemoglobinuria (PNH) patients and for the quantitation of CD59 on normal and decay accelerating factor (DAF)-deficient erythrocytes.
    Fletcher A; Bryant JA; Gardner B; Judson PA; Spring FA; Parsons SF; Mallinson G; Anstee DJ
    Immunology; 1992 Mar; 75(3):507-12. PubMed ID: 1374058
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Detection of PNH clones using flow cytometry in aplastic anemia and paroxysmal nocturnal hemoglobinuria].
    Forés R; Alcocer M; Cabrera R; Sanjuán I; Briz M; Lago C; Fernández MN
    Sangre (Barc); 1999 Jun; 44(3):199-203. PubMed ID: 10481581
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The erythrocytes in paroxysmal nocturnal haemoglobinuria of intermediate sensitivity to complement lysis.
    Rosse WF; Hoffman S; Campbell M; Borowitz M; Moore JO; Parker CJ
    Br J Haematol; 1991 Sep; 79(1):99-107. PubMed ID: 1716964
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Rapid diagnosis of paroxysmal nocturnal hemoglobinuria by gel test agglutination].
    Navenot JM; Bernard D; Petit-Frioux Y; Loirat MJ; Guimbretière J; Muller JY; Blanchard D
    Rev Fr Transfus Hemobiol; 1993 Apr; 36(2):135-47. PubMed ID: 7684909
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Heterogenous expression of decay accelerating factor and CD59/membrane attack complex inhibition factor on paroxysmal nocturnal haemoglobinuria (PNH) erythrocytes.
    Shichishima T; Terasawa T; Hashimoto C; Ohto H; Uchida T; Maruyama Y
    Br J Haematol; 1991 Aug; 78(4):545-50. PubMed ID: 1716957
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A standardized flow cytometric method for screening paroxysmal nocturnal haemoglobinuria (PNH) measuring CD55 and CD59 expression on erythrocytes and granulocytes.
    Oelschlaegel U; Besson I; Arnoulet C; Sainty D; Nowak R; Naumann R; Bux Y; Ehninger G
    Clin Lab Haematol; 2001 Apr; 23(2):81-90. PubMed ID: 11488846
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessing donor chimerism using flow cytometry in paroxysmal nocturnal haemoglobinuria after stem cell transplantation--a case report.
    Azma RZ; Hamidah NH; Leong CF; Ainoon O; Cheong SK
    Malays J Pathol; 2006 Dec; 28(2):107-12. PubMed ID: 18376800
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Flow cytometry and immunoblotting analysis of monoclonal antibodies directed to complement regulatory proteins.
    Blanchard D; Navenot JM; Petit-Le Roux Y; Willem C; Loirat MJ
    Transfus Clin Biol; 1997; 4(1):131-4. PubMed ID: 9095519
    [TBL] [Abstract][Full Text] [Related]  

  • 13. De novo smoldering paroxysmal nocturnal hemoglobinuria: a flow cytometric diagnosis.
    Forés R; Bautista G; Steegmann JL; Javier Peñalver F; Cabrera R; Fernández MN
    Haematologica; 1997; 82(6):695-7. PubMed ID: 9580088
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A simplified assay for the specific diagnosis of paroxysmal nocturnal hemoglobinuria: detection of DAF(CD55)- and HRF20(CD59)- erythrocytes in microtyping cards.
    Nilsson B; Hagström U; Englund A; Säfwenberg J
    Vox Sang; 1993; 64(1):43-6. PubMed ID: 7680511
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [PNH--paroxysmal nocturnal hemoglobinuria. An old disease explained by new technology].
    Hast R
    Lakartidningen; 1997 Nov; 94(47):4323-6. PubMed ID: 9424527
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Longer in vivo survival of CD59- and decay-accelerating factor-almost normal positive and partly positive erythrocytes in paroxysmal nocturnal hemoglobinuria as compared with negative erythrocytes: a demonstration by differential centrifugation and flow cytometry.
    Fujioka S; Yamada T
    Blood; 1992 Apr; 79(7):1842-5. PubMed ID: 1373090
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Negative Ham's test and sugar water test on admission in paroxysmal nocturnal hemoglobinuria].
    Noji H; Shichishima T; Saitoh Y; Yamagiwa A; Maruyama Y
    Rinsho Ketsueki; 1994 Sep; 35(9):898-901. PubMed ID: 7967061
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [CD59-blocked erythrocytes and hemolysis tests of paroxysmal nocturnal hemoglobinuria].
    Gao J; Xie Y
    Zhonghua Xue Ye Xue Za Zhi; 1999 Apr; 20(4):187-90. PubMed ID: 11601225
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evolution of paroxysmal nocturnal hemoglobinuria clone during an hemolytic crisis in a patient with aplastic anemia. Flow cytometry study].
    Canalejo K; Galassi N; Riera N; Bengió R; Aixalá M
    Medicina (B Aires); 2001; 61(5 Pt 1):581-4. PubMed ID: 11721326
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Blood cell flow cytometry in paroxysmal nocturnal hemoglobinuria: a tool for measuring the extent of the PNH clone.
    Alfinito F; Del Vecchio L; Rocco S; Boccuni P; Musto P; Rotoli B
    Leukemia; 1996 Aug; 10(8):1326-30. PubMed ID: 8709638
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.