204 related articles for article (PubMed ID: 10611197)
1. Ultrasound-guided soft catheter embryo transfers will improve pregnancy rates in in-vitro fertilization.
Wood EG; Batzer FR; Go KJ; Gutmann JN; Corson SL
Hum Reprod; 2000 Jan; 15(1):107-12. PubMed ID: 10611197
[TBL] [Abstract][Full Text] [Related]
2. Transvaginal ultrasound-guided embryo transfer in IVF.
Larue L; Keromnes G; Massari A; Roche C; Moulin J; Gronier H; Bouret D; Cassuto NG; Ayel JP
J Gynecol Obstet Hum Reprod; 2017 May; 46(5):411-416. PubMed ID: 28428123
[TBL] [Abstract][Full Text] [Related]
3. Does the choice of catheter for embryo transfer influence the success rate of in-vitro fertilization?
Gonen Y; Dirnfeld M; Goldman S; Koifman M; Abramovici H
Hum Reprod; 1991 Sep; 6(8):1092-4. PubMed ID: 1806567
[TBL] [Abstract][Full Text] [Related]
4. Firm versus soft embryo transfer catheters under ultrasound guidance: does catheter choice really influence the pregnancy rates?
Aboulfotouh I; Abou-Setta AM; Khattab S; Mohsen IA; Askalani A; El-Din RE
Fertil Steril; 2008 May; 89(5):1261-1262. PubMed ID: 17644096
[TBL] [Abstract][Full Text] [Related]
5. Embryo transfer using the SureView catheter-beacon in the womb.
Allahbadia GN; Kadam K; Gandhi G; Arora S; Valliappan JB; Joshi A; Allahbadia S; Wolman I
Fertil Steril; 2010 Feb; 93(2):344-50. PubMed ID: 19268930
[TBL] [Abstract][Full Text] [Related]
6. Comparing two embryo transfer catheters. Use of a trial transfer to determine the catheter applied.
Urman B; Aksoy S; Alatas C; Mercan R; Nuhoglu A; Isiklar A; Balaban B
J Reprod Med; 2000 Feb; 45(2):135-8. PubMed ID: 10710745
[TBL] [Abstract][Full Text] [Related]
7. Ultrasound-guided embryo transfer: immediate withdrawal of the catheter versus a 30 second wait.
MartÃnez F; Coroleu B; Parriego M; Carreras O; Belil I; Parera N; Hereter L; Buxaderas R; Barri PN
Hum Reprod; 2001 May; 16(5):871-4. PubMed ID: 11331631
[TBL] [Abstract][Full Text] [Related]
8. Transvaginal ultrasound-guided embryo transfer improves pregnancy and implantation rates after IVF.
Kojima K; Nomiyama M; Kumamoto T; Matsumoto Y; Iwasaka T
Hum Reprod; 2001 Dec; 16(12):2578-82. PubMed ID: 11726577
[TBL] [Abstract][Full Text] [Related]
9. The influence of the depth of embryo replacement into the uterine cavity on in vitro fertilization outcome.
Ivanovski M; Damcevski N; Radevska B; Doicev G
Akush Ginekol (Sofiia); 2012; 51(3):59-67. PubMed ID: 23236668
[TBL] [Abstract][Full Text] [Related]
10. Impact of transabdominal ultrasound guidance on performance and outcome of transcervical uterine embryo transfer.
Mirkin S; Jones EL; Mayer JF; Stadtmauer L; Gibbons WE; Oehninger S
J Assist Reprod Genet; 2003 Aug; 20(8):318-22. PubMed ID: 12948094
[TBL] [Abstract][Full Text] [Related]
11. Transabdominal ultrasound-assisted embryo transfer and pregnancy outcome.
Flisser E; Grifo JA; Krey LC; Noyes N
Fertil Steril; 2006 Feb; 85(2):353-7. PubMed ID: 16595211
[TBL] [Abstract][Full Text] [Related]
12. Transfer of embryos into the uterus: how much do technical factors affect pregnancy rates?
al-Shawaf T; Dave R; Harper J; Linehan D; Riley P; Craft I
J Assist Reprod Genet; 1993 Jan; 10(1):31-6. PubMed ID: 8499676
[TBL] [Abstract][Full Text] [Related]
13. Large randomized trial comparing transabdominal ultrasound-guided embryo transfer with a technique based on uterine length measurement before embryo transfer.
Revelli A; Rovei V; Dalmasso P; Gennarelli G; Racca C; Evangelista F; Benedetto C
Ultrasound Obstet Gynecol; 2016 Sep; 48(3):289-95. PubMed ID: 26924732
[TBL] [Abstract][Full Text] [Related]
14. A prospective randomized comparison of the Wallace catheter and the Cook Echo-Tip catheter for ultrasound-guided embryo transfer.
Karande V; Hazlett D; Vietzke M; Gleicher N
Fertil Steril; 2002 Apr; 77(4):826-30. PubMed ID: 11937141
[TBL] [Abstract][Full Text] [Related]
15. Effect of using an echogenic catheter for ultrasound-guided embryo transfer in an IVF programme: a prospective, randomized, controlled study.
Coroleu B; Barri PN; Carreras O; Belil I; Buxaderas R; Veiga A; Balasch J
Hum Reprod; 2006 Jul; 21(7):1809-15. PubMed ID: 16556674
[TBL] [Abstract][Full Text] [Related]
16. The efficacy of the embryo transfer catheter in IVF and ICSI is operator-dependent: a randomized clinical trial.
Yao Z; Vansteelandt S; Van der Elst J; Coetsier T; Dhont M; De Sutter P
Hum Reprod; 2009 Apr; 24(4):880-7. PubMed ID: 19095665
[TBL] [Abstract][Full Text] [Related]
17. Marked improvement in clinical pregnancy rates following in vitro fertilization-embryo transfer seen when transfer technique and catheter were changed.
Choe JK; Nazari A; Check JH; Summers-Chase D; Swenson K
Clin Exp Obstet Gynecol; 2001; 28(4):223-4. PubMed ID: 11838743
[TBL] [Abstract][Full Text] [Related]
18. A prospective randomized controlled trial of Wallace and Rocket embryo transfer catheters.
El-Shawarby SA; Ravhon A; Skull J; Ellenbogen A; Trew G; Lavery S
Reprod Biomed Online; 2008 Oct; 17(4):549-52. PubMed ID: 18854110
[TBL] [Abstract][Full Text] [Related]
19. Performance of different embryo transfer catheters in a human in vitro fertilization program.
Wisanto A; Janssens R; Deschacht J; Camus M; Devroey P; Van Steirteghem AC
Fertil Steril; 1989 Jul; 52(1):79-84. PubMed ID: 2744191
[TBL] [Abstract][Full Text] [Related]
20. Potentially important variables identified by transvaginal ultrasound-guided embryo transfer.
Woolcott R; Stanger J
Hum Reprod; 1997 May; 12(5):963-6. PubMed ID: 9194648
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]