These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

57 related articles for article (PubMed ID: 10611571)

  • 1. [Determination of focal distance and convergence assessment in collimators with focalized geometry].
    Pareto Onghena D; Pavía Segura J; Juvells Prades I; Falcón Falcón C; Ros Puig D
    Rev Esp Med Nucl; 1999 Dec; 18(6):442-5. PubMed ID: 10611571
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The evaluation and calibration of fan-beam collimators.
    Mahowald JL; Robins PD; O'Connor MK
    Eur J Nucl Med; 1999 Apr; 26(4):314-9. PubMed ID: 10199935
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Angulation errors in parallel-hole and fanbeam collimators: computer controlled quality control and acceptance testing procedure.
    Eckholt M; Bergmann H
    J Nucl Med; 2000 Mar; 41(3):548-55. PubMed ID: 10716331
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Non-diverging analytic expression for the on-axis sensitivity of converging collimators: experimental verification.
    Accorsi R; Metzler SD
    Phys Med Biol; 2006 Nov; 51(21):5697-705. PubMed ID: 17047278
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterisation of fan-beam collimators.
    Pareto D; Pavía J; Falcón C; Juvells I; Cot A; Ros D
    Eur J Nucl Med; 2001 Feb; 28(2):144-9. PubMed ID: 11303883
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Slit slat collimator optimization with respect to MTF.
    Kamali-Asl A; Sarkar S; Shahriari M; Agha-Hosseini H
    Appl Radiat Isot; 2005 Mar; 62(3):461-8. PubMed ID: 15607925
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Modulation transfer function assessment in parallel beam and fan beam collimators with square and cylindrical holes.
    Khorshidi A; Ashoor M
    Ann Nucl Med; 2014 May; 28(4):363-70. PubMed ID: 24570206
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improved estimation of the detector response function for converging beam collimators.
    Frey EC; Tsui BM; Gullberg GT
    Phys Med Biol; 1998 Apr; 43(4):941-50. PubMed ID: 9572517
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.
    Holen RV; Vandenberghe S; Staelens S; De Beenhouwer J; Lemahieu I
    Phys Med Biol; 2009 Feb; 54(3):715-29. PubMed ID: 19131666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fan-beam reconstruction algorithm for a spatially varying focal length collimator.
    Zeng GL; Gullberg GT; Jaszczak RJ; Li J
    IEEE Trans Med Imaging; 1993; 12(3):575-82. PubMed ID: 18218451
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
    Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
    J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of pinhole SPECT acquisition geometry.
    Bequé D; Nuyts J; Bormans G; Suetens P; Dupont P
    IEEE Trans Med Imaging; 2003 May; 22(5):599-612. PubMed ID: 12846429
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Collimators.
    Formiconi AR
    Q J Nucl Med; 2002 Mar; 46(1):8-15. PubMed ID: 12072841
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reconstruction of two- and three-dimensional images from synthetic-collimator data.
    Wilson DW; Barrett HH; Clarkson EW
    IEEE Trans Med Imaging; 2000 May; 19(5):412-22. PubMed ID: 11021685
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-diverging analytical expression for the sensitivity of converging SPECT collimators.
    van Roosmalen J; Goorden MC
    Phys Med Biol; 2017 May; 62(10):N228-N243. PubMed ID: 28445165
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A backprojection filtering algorithm for a spatially varying focal length collimator.
    Zeng GL; Gullberg GT
    IEEE Trans Med Imaging; 1994; 13(3):549-56. PubMed ID: 18218530
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical derivation of the point spread function for pinhole collimators.
    Bal G; Acton PD
    Phys Med Biol; 2006 Oct; 51(19):4923-50. PubMed ID: 16985279
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Non-diverging analytic expression for the on-axis sensitivity of converging collimators: analytic derivation.
    Accorsi R; Metzler SD
    Phys Med Biol; 2006 Nov; 51(21):5675-96. PubMed ID: 17047277
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single and multipinhole collimator design evaluation method for small animal SPECT.
    Vunckx K; Beque D; Defrise M; Nuyts J
    IEEE Trans Med Imaging; 2008 Jan; 27(1):36-46. PubMed ID: 18270060
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modeling the axial extension of a transmission line source within iterative reconstruction via multiple transmission sources.
    Bowsher JE; Tornai MP; Peter J; González Trotter DE; Krol A; Gilland DR; Jaszczak RJ
    IEEE Trans Med Imaging; 2002 Mar; 21(3):200-15. PubMed ID: 11989845
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.