BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 10616156)

  • 1. Monte Carlo calculated output factors of a Leksell Gamma Knife unit.
    Cheung JY; Yu KN; Ho RT; Yu CP
    Phys Med Biol; 1999 Dec; 44(12):N247-9. PubMed ID: 10616156
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Study of scattered photons from the collimator system of Leksell Gamma Knife using the EGS4 Monte Carlo code.
    Cheung JY; Yu KN
    Med Phys; 2006 Jan; 33(1):41-5. PubMed ID: 16485407
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo calculation of single-beam dose profiles used in a gamma knife treatment planning system.
    Cheung JY; Yu KN; Yu CP; Ho RT
    Med Phys; 1998 Sep; 25(9):1673-5. PubMed ID: 9775372
    [TBL] [Abstract][Full Text] [Related]  

  • 4. MCNP-based computational model for the Leksell gamma knife.
    Trnka J; Novotny J; Kluson J
    Med Phys; 2007 Jan; 34(1):63-75. PubMed ID: 17278491
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte Carlo simulation of the Leksell Gamma Knife: I. Source modelling and calculations in homogeneous media.
    Moskvin V; DesRosiers C; Papiez L; Timmerman R; Randall M; DesRosiers P
    Phys Med Biol; 2002 Jun; 47(12):1995-2011. PubMed ID: 12118597
    [TBL] [Abstract][Full Text] [Related]  

  • 6. FLUKA Monte Carlo simulation for the Leksell Gamma Knife Perfexion radiosurgery system: homogeneous media.
    Battistoni G; Cappucci F; Bertolino N; Brambilla MG; Mainardi HS; Torresin A
    Phys Med; 2013 Nov; 29(6):656-61. PubMed ID: 22901732
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Precision dosimetry for narrow photon beams used in radiosurgery-determination of Gamma Knife output factors.
    Mack A; Scheib SG; Major J; Gianolini S; Pazmandi G; Feist H; Czempiel H; Kreiner HJ
    Med Phys; 2002 Sep; 29(9):2080-9. PubMed ID: 12349929
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of output factors for the Leksell gamma knife using ion chamber, thermoluminescence detectors and films.
    Bilge H; Osen Z; Senkesen O; Kucucuk H; Cakir A; Sengoz M
    J BUON; 2006; 11(2):223-7. PubMed ID: 17318975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo calculations and GafChromic film measurements for plugged collimator helmets of Leksell Gamma Knife unit.
    Cheung JY; Yu KN; Ho RT; Yu CP
    Med Phys; 1999 Jul; 26(7):1252-6. PubMed ID: 10435525
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations.
    Cheung JY; Yu KN; Yu CP; Ho RT
    Appl Radiat Isot; 2001 Mar; 54(3):461-5. PubMed ID: 11214882
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stereotactic dose planning system used in Leksell Gamma Knife model-B: EGS4 Monte Carlo versus GafChromic films MD-55.
    Cheung YC; Yu KN; Ho RT; Yu CP
    Appl Radiat Isot; 2000 Sep; 53(3):427-30. PubMed ID: 10972148
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte Carlo calculated and experimentally determined output correction factors for small field detectors in Leksell Gamma Knife Perfexion beams.
    Benmakhlouf H; Johansson J; Paddick I; Andreo P
    Phys Med Biol; 2015 May; 60(10):3959-73. PubMed ID: 25909660
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correction of measured Gamma-Knife output factors for angular dependence of diode detectors and PinPoint ionization chamber.
    Hršak H; Majer M; Grego T; Bibić J; Heinrich Z
    Phys Med; 2014 Dec; 30(8):914-9. PubMed ID: 25266988
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of Collimator Helmet Factors for Leksell Gamma Knife 4C Unit Using GAF Chromic EBT3 Film and ImageJ Software.
    Natesan P; Palaniappan SM; M M; Ganesh KM; Bhaskara Rao M
    Asian Pac J Cancer Prev; 2021 Dec; 22(12):4031-4035. PubMed ID: 34967585
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose measurements for gamma knife with radiophotoluminescent glass dosemeter and radiochromic film.
    Hsu SM; Lee JH; Hsu FY; Lee HW; Hung SK; Liao YJ; Lee MS
    Radiat Prot Dosimetry; 2011 Jul; 146(1-3):256-9. PubMed ID: 21493605
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A simple and effective method for validation and measurement of collimator output factors for Leksell Gamma Knife Perfexion.
    Ma L; Kjäll P; Novotny J; Nordström H; Johansson J; Verhey L
    Phys Med Biol; 2009 Jun; 54(12):3897-907. PubMed ID: 19491451
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiosurgery with the world's first fully robotized Leksell Gamma Knife PerfeXion in clinical use: a 200-patient prospective, randomized, controlled comparison with the Gamma Knife 4C.
    Régis J; Tamura M; Guillot C; Yomo S; Muraciolle X; Nagaje M; Arka Y; Porcheron D
    Neurosurgery; 2009 Feb; 64(2):346-55; discussion 355-6. PubMed ID: 19190462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An efficient method of measuring the 4 mm helmet output factor for the Gamma knife.
    Ma L; Li XA; Yu CX
    Phys Med Biol; 2000 Mar; 45(3):729-33. PubMed ID: 10730967
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of penumbra regions produced by ancient Gamma knife model C and Gamma ART 6000 using Monte Carlo MCNP6 simulation.
    Banaee N; Asgari S; Nedaie HA
    Appl Radiat Isot; 2018 Jul; 137():154-160. PubMed ID: 29626754
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A film technique for the determination of output factors and end effect times for the Leksell Gamma Knife.
    Ekstrand KE; Bourland JD
    Phys Med Biol; 2001 Mar; 46(3):703-6. PubMed ID: 11277218
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.