These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 10624635)

  • 21. Measuring the filtration performance of breathing system filters using sodium chloride particles.
    Wilkes AR
    Anaesthesia; 2002 Feb; 57(2):162-8. PubMed ID: 11871953
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Prevention of cross contamination, patient to anesthesia apparatus to patient, using filters].
    Cochs J; Casals P; Villalonga R; Vences A; Irujo J; Suárez M
    Rev Esp Anestesiol Reanim; 1994; 41(6):322-7. PubMed ID: 7838999
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Site of pressure measurement during spontaneous breathing with continuous positive airway pressure: effect on calculating imposed work of breathing.
    Banner MJ; Kirby RR; Blanch PB
    Crit Care Med; 1992 Apr; 20(4):528-33. PubMed ID: 1559368
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Bilateral tension pneumothorax due to a defective anesthesia breathing circuit filter.
    Smith CE; Otworth JR; Kaluszyk P
    J Clin Anesth; 1991; 3(3):229-34. PubMed ID: 1878237
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The effect of loading on the filtration performance of breathing system filters.
    Wilkes AR
    Anaesthesia; 2003 Jun; 58(6):562-7. PubMed ID: 12846622
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Evaluation of 2 bacterial filters connected to the respirator for the prevention of nosocomial pulmonary infection].
    Coustets B; Moatti N; Andrieu P; Decun JF; Mazerolles M
    Agressologie; 1990; 31(8 Spec No):560-2. PubMed ID: 2089987
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An evaluation of the filtration performance of paediatric breathing system filters at low flows.
    Malan CA; Wilkes AR; Hall JE; Gildersleve C
    Anaesthesia; 2007 May; 62(5):504-8. PubMed ID: 17448064
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The bacterial and viral filtration performance of breathing system filters.
    Wilkes AR; Benbough JE; Speight SE; Harmer M
    Anaesthesia; 2000 May; 55(5):458-65. PubMed ID: 10792138
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Breathing system filters for paediatric practice.
    Bennett NR; Bingham R
    Anaesthesia; 2007 Feb; 62(2):192-3; author reply 193. PubMed ID: 17223817
    [No Abstract]   [Full Text] [Related]  

  • 30. Activated charcoal effectively removes inhaled anesthetics from modern anesthesia machines.
    Birgenheier N; Stoker R; Westenskow D; Orr J
    Anesth Analg; 2011 Jun; 112(6):1363-70. PubMed ID: 21543783
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Evaluation of the cost-efficacy ratio of Pall BB 22 15 filters for the bacterial protection of anesthesia circuits].
    Pottecher B; Eberhardt R; Kieny MT; Goetz ML; Heitz A; Dupeyron JP; Bientz M
    Agressologie; 1990; 31(8 Spec No):553-6. PubMed ID: 2128590
    [TBL] [Abstract][Full Text] [Related]  

  • 32. It is not necessary to remove a jet stylet to determine tracheal tube location.
    Goskowicz R; Gaughan S; Benumof JL; Ozaki GT
    J Clin Anesth; 1992; 4(1):42-4. PubMed ID: 1540368
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The Humidity in a Low-Flow Dräger Fabius Anesthesia Workstation with or without Thermal Insulation or a Heat and Moisture Exchanger: A Prospective Randomized Clinical Trial.
    de Oliveira SA; Lucio LM; Modolo NS; Hayashi Y; Braz MG; de Carvalho LR; Braz LG; Braz JR
    PLoS One; 2017; 12(1):e0170723. PubMed ID: 28129353
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients.
    Boots RJ; Howe S; George N; Harris FM; Faoagali J
    Crit Care Med; 1997 Oct; 25(10):1707-12. PubMed ID: 9377886
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Modification to endotracheal tube connectors for cleft lip and palate anesthesia.
    Kumar GS; Kumar JR
    Cleft Palate Craniofac J; 2006 Nov; 43(6):649-50. PubMed ID: 17105334
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Ventilation via a transnasally placed pharyngeal tube. Comparison with mask ventilation].
    Bund M; Walz R; Logemann F; Seitz W; Kirchner E
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1996 Sep; 31(7):420-4. PubMed ID: 8991469
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dialyzer reuse with peracetic acid does not impact patient mortality.
    Bond TC; Nissenson AR; Krishnan M; Wilson SM; Mayne T
    Clin J Am Soc Nephrol; 2011 Jun; 6(6):1368-74. PubMed ID: 21566107
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Breathing circuit mishap resulting from Y-piece disintegration.
    Brown MR; Burris WR; Hilley MD
    Anesthesiology; 1988 Sep; 69(3):436-7. PubMed ID: 3415031
    [No Abstract]   [Full Text] [Related]  

  • 39. Lean and Green Hand Surgery.
    Van Demark RE; Smith VJS; Fiegen A
    J Hand Surg Am; 2018 Feb; 43(2):179-181. PubMed ID: 29421068
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.
    Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D
    Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.