These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
137 related articles for article (PubMed ID: 10625830)
1. Aortic prosthetic valve design and size: relation to Doppler echocardiographic findings and pressure recovery- an in vitro study. Bech-Hanssen O; Caidahl K; Wallentin I; Brandberg J; Wranne B; Ask P J Am Soc Echocardiogr; 2000 Jan; 13(1):39-50. PubMed ID: 10625830 [TBL] [Abstract][Full Text] [Related]
2. [Doppler echocardiographic evaluation of the new mechanical bileaflet Sorin Bicarbon valve prosthesis compared with St. Jude Medical]. Badano L; Carratino L; De Gaetano G; Piazza R; Calisi P; Passerone G; Lucatti A G Ital Cardiol; 1994 Jun; 24(6):733-43. PubMed ID: 8088472 [TBL] [Abstract][Full Text] [Related]
3. Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: an in vivo and in vitro study. Bech-Hanssen O; Caidahl K; Wallentin I; Ask P; Wranne B J Thorac Cardiovasc Surg; 2001 Aug; 122(2):287-95. PubMed ID: 11479501 [TBL] [Abstract][Full Text] [Related]
4. In vitro assessment of prosthesis type and pressure recovery characteristics: Doppler echocardiography overestimation of bileaflet mechanical and bioprosthetic aortic valve gradients. Bach DS; Schmitz C; Dohmen G; Aaronson KD; Steinseifer U; Kleine P J Thorac Cardiovasc Surg; 2012 Aug; 144(2):453-8. PubMed ID: 22264413 [TBL] [Abstract][Full Text] [Related]
5. Doppler-catheter discrepancies in patients with bileaflet mechanical prostheses or bioprostheses in the aortic valve position. Aljassim O; Svensson G; Houltz E; Bech-Hanssen O Am J Cardiol; 2008 Nov; 102(10):1383-9. PubMed ID: 18993160 [TBL] [Abstract][Full Text] [Related]
6. Net pressure gradients in aortic prosthetic valves can be estimated by Doppler. Bech-Hanssen O; Gjertsson P; Houltz E; Wranne B; Ask P; Loyd D; Caidahl K J Am Soc Echocardiogr; 2003 Aug; 16(8):858-66. PubMed ID: 12878995 [TBL] [Abstract][Full Text] [Related]
7. Rest and exercise hemodynamics of 20 to 23 mm allograft, Medtronic Intact (porcine), and St. Jude Medical valves in the aortic position. Jaffe WM; Coverdale HA; Roche AH; Whitlock RM; Neutze JM; Barratt-Boyes BG J Thorac Cardiovasc Surg; 1990 Aug; 100(2):167-74. PubMed ID: 2385114 [TBL] [Abstract][Full Text] [Related]
8. [Doppler echocardiographic evaluation of functional parameters of mechanical and biological valve prostheses]. De Gaetano G; Barberis L; Dottori V; Parodi E; Passerone GC; Lijoi A; Kandil H; Gnecco G; Badano L; Venere G Minerva Cardioangiol; 1993 Sep; 41(9):365-70. PubMed ID: 8259231 [TBL] [Abstract][Full Text] [Related]
9. Doppler assessment of mechanical aortic valve prostheses: effect of valve design and size of the aorta. Mascherbauer J; Schima H; Maurer G; Baumgartner H J Heart Valve Dis; 2004 Sep; 13(5):823-30. PubMed ID: 15473486 [TBL] [Abstract][Full Text] [Related]
10. Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: an in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves. Baumgartner H; Khan S; DeRobertis M; Czer L; Maurer G J Am Coll Cardiol; 1992 Feb; 19(2):324-32. PubMed ID: 1531058 [TBL] [Abstract][Full Text] [Related]
11. Long-term Doppler echocardiographic follow up in normally functioning aortic St. Jude Medical prosthesis. Zimmerli M; Kipfer B; Wagdi P J Heart Valve Dis; 1997 Sep; 6(5):531-4. PubMed ID: 9330176 [TBL] [Abstract][Full Text] [Related]
13. Reference Doppler echocardiographic values for St. Jude Medical, Omnicarbon, and Biocor prosthetic valves in the aortic position. Bech-Hanssen O; Wallentin I; Larsson S; Caidahl K J Am Soc Echocardiogr; 1998 May; 11(5):466-77. PubMed ID: 9619619 [TBL] [Abstract][Full Text] [Related]
14. Assessment of prosthetic valve hemodynamics by Doppler: lessons from in vitro studies of the St. Jude valve. Khan SS J Heart Valve Dis; 1993 Mar; 2(2):183-93. PubMed ID: 8261156 [TBL] [Abstract][Full Text] [Related]
15. Pressure recovery in bileaflet heart valve prostheses. Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position. Vandervoort PM; Greenberg NL; Powell KA; Cosgrove DM; Thomas JD Circulation; 1995 Dec; 92(12):3464-72. PubMed ID: 8521568 [TBL] [Abstract][Full Text] [Related]
17. [Comparative study of Toronto SPV prosthesis and bileaflet mechanical aortic prosthesis with 2D-Doppler echocardiography]. Martins S; Neves F; Soares RM; Cacela D; do Rosário L; Coelho P; Mendes J; Robalo F; Castelão N; Antunes AM; Roquette J Rev Port Cardiol; 1999 Dec; 18(12):1111-6. PubMed ID: 10661018 [TBL] [Abstract][Full Text] [Related]
18. The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis. Bleiziffer S; Eichinger WB; Wagner I; Guenzinger R; Bauernschmitt R; Lange R J Heart Valve Dis; 2005 Nov; 14(6):814-21; discussion 821. PubMed ID: 16359064 [TBL] [Abstract][Full Text] [Related]
19. [Non-invasive determination of pressure gradients of heart valve prostheses using Doppler ultrasound]. Hoffmann A; Amann FW; Grädel E; Burckhardt D Schweiz Med Wochenschr; 1982 Nov; 112(45):1600-3. PubMed ID: 7156956 [TBL] [Abstract][Full Text] [Related]
20. [Continuous wave Doppler assessment of prosthetic valves in the mitral position: comparison of the St. Jude medical mechanical valve and the porcine xenograft valve]. Kisanuki A; Tei C; Arikawa K; Natsugoe K; Otsuji Y; Kawazoe Y; Tanaka H; Morishita Y; Maruko M; Taira A J Cardiogr; 1985 Dec; 15(4):1119-27. PubMed ID: 3841894 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]