148 related articles for article (PubMed ID: 10629021)
1. Comparison of PCR detection of mecA with methicillin and oxacillin disc susceptibility testing in coagulase-negative staphylococci.
Graham JC; Murphy OM; Stewart D; Kearns AM; Galloway A; Freeman R
J Antimicrob Chemother; 2000 Jan; 45(1):111-3. PubMed ID: 10629021
[TBL] [Abstract][Full Text] [Related]
2. A comparison of PCR detection of mecA with two standard methods of oxacillin disk susceptibility testing for coagulase-negative staphylococci.
Tan TY
J Med Microbiol; 2002 Jan; 51(1):83-5. PubMed ID: 11800477
[TBL] [Abstract][Full Text] [Related]
3. Laboratory detection methods for methicillin resistance in coagulase negative Staphylococcus isolated from ophthalmic infections.
Oliveira AD; d'Azevedo PA; de Sousa LB; Viana-Niero C; Francisco W; Lottenberg C; Martino MD; Höfling-Lima AL
Arq Bras Oftalmol; 2007; 70(4):667-75. PubMed ID: 17906764
[TBL] [Abstract][Full Text] [Related]
4. Comparison of PCR detection of mecA with standard susceptibility testing methods to determine methicillin resistance in coagulase-negative staphylococci.
York MK; Gibbs L; Chehab F; Brooks GF
J Clin Microbiol; 1996 Feb; 34(2):249-53. PubMed ID: 8788995
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of the Vitek card GPS105 and VTK-RO7.01 software for detection of oxacillin resistance in clinically relevant coagulase-negative staphylococci.
Martinez F; Chandler LJ; Reisner BS; Woods GL
J Clin Microbiol; 2001 Oct; 39(10):3733-5. PubMed ID: 11574604
[TBL] [Abstract][Full Text] [Related]
6. Comparison of the Vitek gram-positive susceptibility 106 card, the MRSA-Screen latex agglutination test, and mecA analysis for detecting oxacillin resistance in a geographically diverse collection of clinical isolates of coagulase-negative staphylococci.
Yamazumi T; Furuta I; Diekema DJ; Pfaller MA; Jones RN
J Clin Microbiol; 2001 Oct; 39(10):3633-6. PubMed ID: 11574584
[TBL] [Abstract][Full Text] [Related]
7. Correlation between genotype and phenotypic categorization of staphylococci based on methicillin susceptibility and resistance.
Gradelski E; Valera L; Aleksunes L; Bonner D; Fung-Tomc J
J Clin Microbiol; 2001 Aug; 39(8):2961-3. PubMed ID: 11474022
[TBL] [Abstract][Full Text] [Related]
8. Correlation of oxacillin MIC with mecA gene carriage in coagulase-negative staphylococci.
Hussain Z; Stoakes L; Massey V; Diagre D; Fitzgerald V; El Sayed S; Lannigan R
J Clin Microbiol; 2000 Feb; 38(2):752-4. PubMed ID: 10655380
[TBL] [Abstract][Full Text] [Related]
9. Comparison of PCR detection of mecA with agar dilution and Etest for oxacillin susceptibility testing in clinical isolates of coagulase-negative staphylococci.
Tveten Y; Jenkins A; Digranes A; Melby KK; Allum AG; Kristiansen BE
Clin Microbiol Infect; 2004 May; 10(5):462-5. PubMed ID: 15113327
[TBL] [Abstract][Full Text] [Related]
10. Adjunctive mecA PCR for routine detection of methicillin susceptibility in clinical isolates of coagulase-negative staphylococci.
Nijjar CK; Smith MH; Eltringham IJ
J Clin Microbiol; 2014 May; 52(5):1678-81. PubMed ID: 24622101
[TBL] [Abstract][Full Text] [Related]
11. Comparison of Oxacillin and Cefoxitin for the Detection of mecAGene to Determine Methicillin Resistance in Coagulase Negative Staphylococci(CoNs).
Shah DA; Wasim S; Abdullah FE
J Coll Physicians Surg Pak; 2017 Aug; 27(8):520-522. PubMed ID: 28903850
[TBL] [Abstract][Full Text] [Related]
12. A comparison of PCR detection of mecA with oxacillin disk susceptibility testing in different media and sceptor automated system for both Staphylococcus aureus and coagulase-negative staphylococci isolates.
Ercis S; Sancak B; Hasçelik G
Indian J Med Microbiol; 2008; 26(1):21-4. PubMed ID: 18227592
[TBL] [Abstract][Full Text] [Related]
13. Identification of mecA-related oxacillin resistance in staphylococci by the E test and the broth microdilution method.
Petersson AC; Miorner H; Kamme C
J Antimicrob Chemother; 1996 Mar; 37(3):445-56. PubMed ID: 9182101
[TBL] [Abstract][Full Text] [Related]
14. Methicillin resistance among staphylococci isolated from dogs.
Gortel K; Campbell KL; Kakoma I; Whittem T; Schaeffer DJ; Weisiger RM
Am J Vet Res; 1999 Dec; 60(12):1526-30. PubMed ID: 10622162
[TBL] [Abstract][Full Text] [Related]
15. A comparative evaluation of phenotypic and molecular methods for the detection of oxacillin resistance in coagulase-negative staphylococci.
Ghoshal U; Prasad KN; Singh M; Tiwari DP; Ayyagari A
J Infect Chemother; 2004 Apr; 10(2):86-9. PubMed ID: 15160300
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of a latex agglutination test (MRSA-Screen) for detection of oxacillin resistance in coagulase-negative Staphylococci.
Louie L; Majury A; Goodfellow J; Louie M; Simor AE
J Clin Microbiol; 2001 Nov; 39(11):4149-51. PubMed ID: 11682545
[TBL] [Abstract][Full Text] [Related]
17. Identification and characterization of methicillin-resistant coagulase-negative staphylococci from bovine mastitis.
Fessler AT; Billerbeck C; Kadlec K; Schwarz S
J Antimicrob Chemother; 2010 Aug; 65(8):1576-82. PubMed ID: 20525989
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of reference values for phenotypic tests to detect oxacillin resistance in coagulase-negative staphylococci.
Pinheiro L; Mello PL; Abraão LM; Corrente JE; Lourdes Rs Cunha M
Future Microbiol; 2018 Apr; 13():565-575. PubMed ID: 29521121
[TBL] [Abstract][Full Text] [Related]
19. Rapid detection of methicillin resistance in coagulase-negative staphylococci by a penicillin-binding protein 2a-specific latex agglutination test.
Horstkotte MA; Knobloch JK; Rohde H; Mack D
J Clin Microbiol; 2001 Oct; 39(10):3700-2. PubMed ID: 11574595
[TBL] [Abstract][Full Text] [Related]
20. Detection of methicillin resistance in coagulase-negative staphylococci initially reported as methicillin susceptible using automated methods.
Ramotar K; Bobrowska M; Jessamine P; Toye B
Diagn Microbiol Infect Dis; 1998 Apr; 30(4):267-73. PubMed ID: 9582587
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]