These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 10642128)

  • 1. Improved efficacy of anodal biphasic defibrillation shocks following a failed defibrillation attempt.
    Roberts PR; Allen S; Smith DC; Urban JF; Euler DE; Kallok MJ; Morgan JM
    Pacing Clin Electrophysiol; 1999 Dec; 22(12):1753-9. PubMed ID: 10642128
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of ventricular fibrillation duration and a preceding unsuccessful shock on the probability of defibrillation success using biphasic waveforms in pigs.
    Windecker S; Kay GN; KenKnight BH; Walcott GP; Smith WM; Ideker RE
    J Cardiovasc Electrophysiol; 1997 Dec; 8(12):1386-95. PubMed ID: 9436776
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimized pulse durations minimize the effect of polarity reversal on defibrillation efficacy with biphasic shocks.
    Schauerte P; Schöndube FA; Grossmann M; Messmer BJ; Hanrath P; Stellbrink C
    Pacing Clin Electrophysiol; 1999 May; 22(5):790-7. PubMed ID: 10353140
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of polarity for monophasic and biphasic shocks on defibrillation efficacy with an endocardial system.
    Usui M; Walcott GP; Strickberger SA; Rollins DL; Smith WM; Ideker RE
    Pacing Clin Electrophysiol; 1996 Jan; 19(1):65-71. PubMed ID: 8848379
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of shock timing on defibrillation success.
    Hsu W; Lin Y; Heil JE; Jones J; Lang DJ
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 2):153-7. PubMed ID: 9121980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of polarity on defibrillation thresholds using a biphasic waveform in a hot can electrode system.
    Yamanouchi Y; Mowrey KA; Nadzam GR; Hills DG; Kroll MW; Brewer JE; Donohoo AM; Wilkoff BL; Tchou PJ
    Pacing Clin Electrophysiol; 1997 Dec; 20(12 Pt 1):2911-6. PubMed ID: 9455750
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function.
    Tang W; Weil MH; Sun S; Yamaguchi H; Povoas HP; Pernat AM; Bisera J
    J Am Coll Cardiol; 1999 Sep; 34(3):815-22. PubMed ID: 10483965
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrode polarity is an important determinant of defibrillation efficacy using a nonthoracotomy system.
    Thakur RK; Souza JJ; Chapman PD; Troup PJ; Wetherbee JN
    Pacing Clin Electrophysiol; 1994 May; 17(5 Pt 1):919-23. PubMed ID: 8022704
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of first-phase polarity of biphasic shocks on defibrillation threshold with a single transvenous lead system.
    Strickberger SA; Man KC; Daoud E; Neary MP; Horwood LE; Niebauer M; Hummel JD; Morady F
    J Am Coll Cardiol; 1995 Jun; 25(7):1605-8. PubMed ID: 7759712
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of electrode polarity on internal defibrillation with monophasic and biphasic waveforms using an endocardial lead system.
    Huang J; KenKnight BH; Walcott GP; Walker RG; Smith WM; Ideker RE
    J Cardiovasc Electrophysiol; 1997 Feb; 8(2):161-71. PubMed ID: 9048247
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surgical open-chest ventricular defibrillation: triphasic waveforms are superior to biphasic waveforms.
    Zhang Y; Boddicker KA; Davies LR; Jones JL; Kerber RE
    Pacing Clin Electrophysiol; 2004 Jul; 27(7):941-8. PubMed ID: 15271014
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Defibrillation probability and impedance change between shocks during resuscitation from out-of-hospital cardiac arrest.
    Walker RG; Koster RW; Sun C; Moffat G; Barger J; Dodson PP; Chapman FW
    Resuscitation; 2009 Jul; 80(7):773-7. PubMed ID: 19423211
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of pulse separation between two sequential biphasic shocks given over different lead configurations on ventricular defibrillation efficacy.
    Johnson EE; Alferness CA; Wolf PD; Smith WM; Ideker RE
    Circulation; 1992 Jun; 85(6):2267-74. PubMed ID: 1591840
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of transesophageal defibrillation in ventricular fibrillation of long duration.
    Mischke K; Schimpf T; Knackstedt C; Eickholt C; Hanrath P; Kelm M; Schauerte P
    Am J Emerg Med; 2008 Mar; 26(3):287-90. PubMed ID: 18358938
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Shock timing lowers transvenous defibrillation energy requirement.
    Hsu W; Lin Y; Lang DJ; Jones JL
    J Electrocardiol; 1998; 31 Suppl():35-40. PubMed ID: 9988003
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effects of ventricular fibrillation duration and site of initiation on the defibrillation threshold during early ventricular fibrillation.
    Strobel JS; Kenknight BH; Rollins DL; Smith WM; Ideker RE
    J Am Coll Cardiol; 1998 Aug; 32(2):521-7. PubMed ID: 9708486
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of biphasic and monophasic waveform defibrillation after prolonged ventricular fibrillation.
    Tang W; Weil MH; Sun S; Povoas HP; Klouche K; Kamohara T; Bisera J
    Chest; 2001 Sep; 120(3):948-54. PubMed ID: 11555534
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Efficacy of lower-energy biphasic shocks for transthoracic defibrillation: a follow-up clinical study.
    Higgins SL; O'Grady SG; Banville I; Chapman FW; Schmitt PW; Lank P; Walker RG; Ilina M
    Prehosp Emerg Care; 2004; 8(3):262-7. PubMed ID: 15295725
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Defibrillation threshold and cardiac responses using an external biphasic defibrillator with pediatric and adult adhesive patches in pediatric-sized piglets.
    Killingsworth CR; Melnick SB; Chapman FW; Walker RG; Smith WM; Ideker RE; Walcott GP
    Resuscitation; 2002 Nov; 55(2):177-85. PubMed ID: 12413756
    [TBL] [Abstract][Full Text] [Related]  

  • 20. External exponential biphasic versus monophasic shock waveform: efficacy in ventricular fibrillation of longer duration.
    Yamanouchi Y; Brewer JE; Donohoo AM; Mowrey KA; Wilkoff BL; Tchou PJ
    Pacing Clin Electrophysiol; 1999 Oct; 22(10):1481-7. PubMed ID: 10588150
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.