These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
271 related articles for article (PubMed ID: 10645369)
1. Fracture healing of the sheep tibia treated using a unilateral external fixator. Comparison of static and dynamic fixation. Hente R; Cordey J; Rahn BA; Maghsudi M; von Gumppenberg S; Perren SM Injury; 1999; 30 Suppl 1():A44-51. PubMed ID: 10645369 [TBL] [Abstract][Full Text] [Related]
3. Biomechanical evaluation of healing in a non-critical defect in a large animal model of osteoporosis. Lill CA; Hesseln J; Schlegel U; Eckhardt C; Goldhahn J; Schneider E J Orthop Res; 2003 Sep; 21(5):836-42. PubMed ID: 12919871 [TBL] [Abstract][Full Text] [Related]
4. 3D Printing Adjustable Stiffness External Fixator for Mechanically Stimulated Healing of Tibial Fractures. Li H; Li D; Qiao F; Tang L; Han Q Biomed Res Int; 2021; 2021():8539416. PubMed ID: 34977247 [TBL] [Abstract][Full Text] [Related]
5. Shear movement at the fracture site delays healing in a diaphyseal fracture model. Augat P; Burger J; Schorlemmer S; Henke T; Peraus M; Claes L J Orthop Res; 2003 Nov; 21(6):1011-7. PubMed ID: 14554213 [TBL] [Abstract][Full Text] [Related]
7. The course of bone healing is influenced by the initial shear fixation stability. Schell H; Epari DR; Kassi JP; Bragulla H; Bail HJ; Duda GN J Orthop Res; 2005 Sep; 23(5):1022-8. PubMed ID: 15878254 [TBL] [Abstract][Full Text] [Related]
8. The effects of dynamization and destabilization of the external fixator on fracture healing: a comparative biomechanical study in dogs. Arazi M; Yalcin H; Tarakcioglu N; Dasci Z; Kutlu A Orthopedics; 2002 May; 25(5):521-4. PubMed ID: 12046912 [TBL] [Abstract][Full Text] [Related]
9. Load transmission through the callus site with external fixation systems: theoretical and experimental analysis. Prat J; Juan JA; Vera P; Hoyos JV; Dejoz R; Peris JL; Sánchez-Lacuesta J; Comín M J Biomech; 1994 Apr; 27(4):469-78. PubMed ID: 8188727 [TBL] [Abstract][Full Text] [Related]
10. CYR61 (CCN1) protein expression during fracture healing in an ovine tibial model and its relation to the mechanical fixation stability. Lienau J; Schell H; Epari DR; Schütze N; Jakob F; Duda GN; Bail HJ J Orthop Res; 2006 Feb; 24(2):254-62. PubMed ID: 16435358 [TBL] [Abstract][Full Text] [Related]
11. Effects of one-plane and two-plane external fixation on sheep osteotomy healing and complications. Krischak GD; Janousek A; Wolf S; Augat P; Kinzl L; Claes LE Clin Biomech (Bristol); 2002 Jul; 17(6):470-6. PubMed ID: 12135549 [TBL] [Abstract][Full Text] [Related]
12. The influence of cyclic compression and distraction on the healing of experimental tibial fractures. Hente R; Füchtmeier B; Schlegel U; Ernstberger A; Perren SM J Orthop Res; 2004 Jul; 22(4):709-15. PubMed ID: 15183425 [TBL] [Abstract][Full Text] [Related]
13. The influence of compression on the healing of experimental tibial fractures. Sigurdsen U; Reikeras O; Utvag SE Injury; 2011 Oct; 42(10):1152-6. PubMed ID: 20850739 [TBL] [Abstract][Full Text] [Related]
14. [The dynamization of external fixation for treatment of open tibia and fibula fractures]. Ma J; Zhang T; Hai B; Cao H; Yong W; Ge Q; Zhang N; Liu Z; Wan C Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Feb; 32(2):174-177. PubMed ID: 29806407 [TBL] [Abstract][Full Text] [Related]
15. A 3D computational simulation of fracture callus formation: influence of the stiffness of the external fixator. Gómez-Benito MJ; García-Aznar JM; Kuiper JH; Doblaré M J Biomech Eng; 2006 Jun; 128(3):290-9. PubMed ID: 16706578 [TBL] [Abstract][Full Text] [Related]
16. [Dynamization of fracture fixation : Timing and methods]. Claes L Unfallchirurg; 2018 Jan; 121(1):3-9. PubMed ID: 29318341 [TBL] [Abstract][Full Text] [Related]
17. Bone-healing patterns affected by loading, fracture fragment stability, fracture type, and fracture site compression. Aro HT; Chao EY Clin Orthop Relat Res; 1993 Aug; (293):8-17. PubMed ID: 8339513 [TBL] [Abstract][Full Text] [Related]
18. Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep. Richter H; Plecko M; Andermatt D; Frigg R; Kronen PW; Klein K; Nuss K; Ferguson SJ; Stöckle U; von Rechenberg B J Bone Joint Surg Am; 2015 Feb; 97(3):208-15. PubMed ID: 25653321 [TBL] [Abstract][Full Text] [Related]
19. Novel external fixation fracture method with circular locking mechanism compared with the application of dynamic axial external fixator on experimental tibial model ensures better stability in bending and favourable performance in dynamic loads. Pavic A; Kodvanj J; Sabalic S; Cukelj F; Bakota B Injury; 2013 Sep; 44 Suppl 3():S52-5. PubMed ID: 24060020 [TBL] [Abstract][Full Text] [Related]
20. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study. Ma CH; Wu CH; Tu YK; Lin TS Injury; 2013 Aug; 44(8):1097-101. PubMed ID: 23706173 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]