These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

70 related articles for article (PubMed ID: 10649692)

  • 1. CAPD with a night-exchange device is the only true CAPD?
    Pagé DE
    Adv Perit Dial; 1998; 14():60-3. PubMed ID: 10649692
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role still exists for cycler therapy in anuric patients with a low-transport membrane.
    Pagé DE; Cheung V
    Adv Perit Dial; 2001; 17():114-6. PubMed ID: 11510256
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The importance of an extra hour of cycler therapy to obtain better adequacy.
    Pagé DE; Smith CA
    Adv Perit Dial; 1999; 15():144-6. PubMed ID: 10682090
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparing an additional hour of cycler therapy to an additional midday exchange to achieve adequacy targets.
    Pagé DE
    Adv Perit Dial; 2000; 16():102-3. PubMed ID: 11045271
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimating the daily dialysate drain volume required in CAPD for a target peritoneal creatinine clearance by body water and peritoneal transport characteristics.
    Rao P; Tzamaloukas AH; Murata GH; Piraino B; Malhotra D; Bernardini J; Oreopoulos DG
    Adv Perit Dial; 1997; 13():33-7. PubMed ID: 9360647
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bridging the Quantum gap: attaining adequacy utilizing the Quantum night-time exchange device.
    Smith CA; Boyer M; Raby E
    CANNT J; 1999; 9(3):28-32; quiz 33-4. PubMed ID: 15712470
    [TBL] [Abstract][Full Text] [Related]  

  • 7. KT/V: the denominator dilemma.
    Lindholm B; Waniewski J; Weryński A
    Pol Merkur Lekarski; 2003 Oct; 15(88):311-5. PubMed ID: 14974355
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adequacy of dialysis in CAPD and cycler PD; the PET is enough.
    Wolf CJ; Polsky J; Ntoso KA; Koethe JD; Gerhardt RE
    Adv Perit Dial; 1992; 8():208-11. PubMed ID: 1361788
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term follow-up of patients treated with a combination of continuous ambulatory peritoneal dialysis and hemodialysis.
    Hoshi H; Nakamoto H; Kanno Y; Takane H; Ikeda N; Sugahara S; Okada H; Suzuki H
    Adv Perit Dial; 2006; 22():136-40. PubMed ID: 16983957
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical value of standardized equilibration tests in CAPD patients.
    Twardowski ZJ
    Blood Purif; 1989; 7(2-3):95-108. PubMed ID: 2663040
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transport of peritoneal membrane assessed before and after the start of peritoneal dialysis.
    La Milia V; Limardo M; Cavalli A; Crepaldi M; Locatelli F
    Nephrol Dial Transplant; 2009 Sep; 24(9):2894-8. PubMed ID: 19349295
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computation of the dose of continuous peritoneal dialysis required for adequate peritoneal urea clearance without taking into account peritoneal transport indices.
    Tzamaloukas AH; Onime A; Raj DS; Murata GH; VanderJagt DJ; Servilla KS
    Adv Perit Dial; 2007; 23():122-6. PubMed ID: 17886617
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Usefulness of the dialysis adequacy and transport test in peritoneal dialysis.
    Seo JJ; Kim YL; Park SH; Kim CD; Kim JC; Jang MH; Choi HJ
    Adv Perit Dial; 2005; 21():25-30. PubMed ID: 16686280
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Once-weekly hemodialysis helps continuous ambulatory peritoneal dialysis patients who have insufficient solute removal.
    Kanno Y; Suzuki H; Nakamoto H; Okada H; Sugahara S
    Adv Perit Dial; 2003; 19():143-7. PubMed ID: 14763051
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of the preceding exchange on peritoneal equilibration test results.
    Figueiredo AE; Conti A; Poli de Figueiredo CE
    Adv Perit Dial; 2002; 18():75-7. PubMed ID: 12402592
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Short peritoneal equilibration test: impact of preceding dwell time.
    Twardowski ZJ; Prowant BF; Moore HL; Lou LC; White E; Farris K
    Adv Perit Dial; 2003; 19():53-8. PubMed ID: 14763034
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A detailed analysis of sodium removal by peritoneal dialysis: comparison with predictions from the three-pore model of membrane function.
    Aanen MC; Venturoli D; Davies SJ
    Nephrol Dial Transplant; 2005 Jun; 20(6):1192-200. PubMed ID: 15827048
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low serum albumin in elderly continuous ambulatory peritoneal dialysis patients is attributable to high permeability of peritoneum.
    Nakamoto H; Imai H; Kawanishi H; Nakamoto M; Minakuchi J; Kumon S; Watanabe S; Shiohira Y; Ishii T; Kawahara T; Suzuki H
    Adv Perit Dial; 2001; 17():238-43. PubMed ID: 11510284
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcome for continuous ambulatory peritoneal dialysis patients is not predicted by peritoneal permeability characteristics.
    Passadakis PS; Thodis ED; Panagoutsos SA; Selisiou CA; Pitta EM; Vargemezis VA
    Adv Perit Dial; 2000; 16():2-6. PubMed ID: 11045251
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Body surface area limitations in achieving adequate therapy in peritoneal dialysis patients.
    Rocco MV
    Perit Dial Int; 1996; 16(6):617-22. PubMed ID: 8981531
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.