These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 10654508)

  • 61. Composite Y Grafts From the Left Internal Mammary Artery: Current Considerations.
    Paterson HS; Bannon PG
    Heart Lung Circ; 2018 Feb; 27(2):133-137. PubMed ID: 29126818
    [TBL] [Abstract][Full Text] [Related]  

  • 62. A randomized comparison of radial-artery and saphenous-vein coronary bypass grafts.
    Desai ND; Cohen EA; Naylor CD; Fremes SE;
    N Engl J Med; 2004 Nov; 351(22):2302-9. PubMed ID: 15564545
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Radial artery grafts vs saphenous vein grafts in coronary artery bypass surgery: a randomized trial.
    Goldman S; Sethi GK; Holman W; Thai H; McFalls E; Ward HB; Kelly RF; Rhenman B; Tobler GH; Bakaeen FG; Huh J; Soltero E; Moursi M; Haime M; Crittenden M; Kasirajan V; Ratliff M; Pett S; Irimpen A; Gunnar W; Thomas D; Fremes S; Moritz T; Reda D; Harrison L; Wagner TH; Wang Y; Planting L; Miller M; Rodriguez Y; Juneman E; Morrison D; Pierce MK; Kreamer S; Shih MC; Lee K
    JAMA; 2011 Jan; 305(2):167-74. PubMed ID: 21224458
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Novadaq SPY: intraoperative quality assessment in off-pump coronary artery bypass grafting.
    Reuthebuch O; Häussler A; Genoni M; Tavakoli R; Odavic D; Kadner A; Turina M
    Chest; 2004 Feb; 125(2):418-24. PubMed ID: 14769718
    [TBL] [Abstract][Full Text] [Related]  

  • 65. [Coronary artery bypass grafting without cardiopulmonary bypass: angiographic evaluation of a preliminary experience].
    Carrier M; Lespérance J; Côté G; Pellerin M; Searle N; Pelletier LC
    Can J Cardiol; 1997 Jul; 13(7):653-6. PubMed ID: 9264861
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Sequential radial artery grafts for multivessel coronary artery bypass graft surgery: 10-year survival and angiography results.
    Schwann TA; Zacharias A; Riordan CJ; Durham SJ; Shah AS; Habib RH
    Ann Thorac Surg; 2009 Jul; 88(1):31-9. PubMed ID: 19559184
    [TBL] [Abstract][Full Text] [Related]  

  • 67. The effects of conventional extracorporeal circulation versus miniaturized extracorporeal circulation on microcirculation during cardiopulmonary bypass-assisted coronary artery bypass graft surgery.
    Yuruk K; Bezemer R; Euser M; Milstein DM; de Geus HH; Scholten EW; de Mol BA; Ince C
    Interact Cardiovasc Thorac Surg; 2012 Sep; 15(3):364-70. PubMed ID: 22700685
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Bi-directional single anastomotic technique for the proximal anastomosis of free grafts (the saphenous vein or radial artery) to the ascending aorta in coronary artery bypass grafting surgery.
    Nabuchi A; Kurata A; Tsukuda K; Miyoshi Y
    Ann Thorac Cardiovasc Surg; 2001 Apr; 7(2):122-4. PubMed ID: 11371286
    [TBL] [Abstract][Full Text] [Related]  

  • 69. An intraluminal shunt for off-pump coronary artery bypass grafting. Report of 501 consecutive cases and review of the technique.
    Rivetti LA; Gandra SM
    Heart Surg Forum; 1998; 1(1):30-6. PubMed ID: 11276437
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Lateral MIDCAB grafting via limited posterior thoracotomy.
    Fonger JD; Doty JR; Sussman MS; Salomon NW
    Eur J Cardiothorac Surg; 1997 Sep; 12(3):399-404; discussion 404-5. PubMed ID: 9332918
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Management of patent saphenous vein grafts during reoperative coronary artery bypass grafting.
    Devineni R; Shah N; Kolff J
    Ann Thorac Surg; 1993 Mar; 55(3):770-1. PubMed ID: 8452449
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Total arterial myocardial revascularization using composite and sequential grafting with the off-pump technique.
    Fukui T; Takanashi S; Hosoda Y; Suehiro S
    Ann Thorac Surg; 2005 Aug; 80(2):579-85. PubMed ID: 16039209
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Flow characteristics of LIMA radial composite sequential bypass grafting and single LIMA and saphenous vein sequential bypass grafting performed under OPCAB.
    Jung JS; Chung CH; Lee SH; Cho SH; Lee JH; Ryu JG; Song H; Lee JW; Choo SJ
    J Cardiovasc Surg (Torino); 2012 Aug; 53(4):537-44. PubMed ID: 22854531
    [TBL] [Abstract][Full Text] [Related]  

  • 74. A simple distal coronary perfusion technique in off-pump coronary artery bypass.
    Ohtsuka T; Motomura N; Suematsu Y; Takamoto S
    Eur J Cardiothorac Surg; 2002 Sep; 22(3):443-4. PubMed ID: 12204740
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Conduits in coronary artery bypass grafting.
    Bakaeen FG; Zenati MA; Bhatt DL
    Semin Thorac Cardiovasc Surg; 2013; 25(4):273-9. PubMed ID: 24673955
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Computational model of blood flow in the aorto-coronary bypass graft.
    Sankaranarayanan M; Chua LP; Ghista DN; Tan YS
    Biomed Eng Online; 2005 Mar; 4():14. PubMed ID: 15745458
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Arterial grafting for myocardial revascularization: how better is it?
    Ferrari ER; von Segesser LK
    Curr Opin Cardiol; 2006 Nov; 21(6):584-8. PubMed ID: 17053408
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Should all moderate coronary lesions be grafted during primary coronary bypass surgery? An analysis of progression of native vessel disease during a randomized trial of conduits.
    Hayward PA; Zhu YY; Nguyen TT; Hare DL; Buxton BF
    J Thorac Cardiovasc Surg; 2013 Jan; 145(1):140-8; discussion 148-9. PubMed ID: 23084100
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Radial artery, saphenous vein versus left internal thoracic artery in recurrent ischemic symptoms after coronary artery bypass graft surgery.
    Günday M; Coşkun I; Çiftçi Ö; Özülkü M; Tekindal MA; Güven A; Aşlamacı S
    Arch Iran Med; 2014 Aug; 17(8):551-5. PubMed ID: 25065278
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Intracoronary shunts reduce transient intraoperative myocardial dysfunction during off-pump coronary operations.
    Yeatman M; Caputo M; Narayan P; Ghosh AK; Ascione R; Ryder I; Angelini GD
    Ann Thorac Surg; 2002 May; 73(5):1411-7. PubMed ID: 12022525
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.