These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 10658336)

  • 1. Secondary electrospray ionization ion mobility spectrometry/mass spectrometry of illicit drugs.
    Wu C; Siems WF; Hill HH
    Anal Chem; 2000 Jan; 72(2):396-403. PubMed ID: 10658336
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hair analysis for illicit drugs by using capillary zone electrophoresis-electrospray ionization-ion trap mass spectrometry.
    Gottardo R; Bortolotti F; De Paoli G; Pascali JP; Miksík I; Tagliaro F
    J Chromatogr A; 2007 Aug; 1159(1-2):185-9. PubMed ID: 17240388
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a plug-type IMS-MS instrument and its applications in resolving problems existing in in-situ detection of illicit drugs and explosives by IMS.
    Du Z; Sun T; Zhao J; Wang D; Zhang Z; Yu W
    Talanta; 2018 Jul; 184():65-72. PubMed ID: 29674084
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterizing bacterial volatiles using secondary electrospray ionization mass spectrometry (SESI-MS).
    Bean HD; Zhu J; Hill JE
    J Vis Exp; 2011 Jun; (52):. PubMed ID: 21694687
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrospray ionization tandem mass spectrometry for the simultaneous determination of opiates and cocaine in human hair.
    Míguez-Framil M; Moreda-Piñeiro A; Bermejo-Barrera P; Cocho JÁ; Tabernero MJ; Bermejo AM
    Anal Chim Acta; 2011 Oct; 704(1-2):123-32. PubMed ID: 21907029
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of new synthetic drugs by ion mobility time-of-flight mass spectrometry.
    Sysoev AA; Poteshin SS; Chernyshev DM; Karpov AV; Tuzkov YB; Kyzmin VV; Sysoev AA
    Eur J Mass Spectrom (Chichester); 2014; 20(2):185-92. PubMed ID: 24895779
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid, in situ detection of cocaine residues based on paper spray ionization coupled with ion mobility spectrometry.
    Li M; Zhang J; Jiang J; Zhang J; Gao J; Qiao X
    Analyst; 2014 Apr; 139(7):1687-91. PubMed ID: 24563903
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Desorption electrospray ionization mass spectrometry: direct toxicological screening and analysis of illicit Ecstasy tablets.
    Leuthold LA; Mandscheff JF; Fathi M; Giroud C; Augsburger M; Varesio E; Hopfgartner G
    Rapid Commun Mass Spectrom; 2006; 20(2):103-10. PubMed ID: 16331738
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.
    Cha E; Kim S; Kim HJ; Lee KM; Kim KH; Kwon OS; Lee J
    Drug Test Anal; 2015; 7(11-12):1040-9. PubMed ID: 26489966
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Liquid chromatography-quadrupole-time-of-flight mass spectrometry screening procedure for urine samples in forensic casework compared to gas chromatography-mass spectrometry.
    Fels H; Dame T; Sachs H; Musshoff F
    Drug Test Anal; 2017 May; 9(5):824-830. PubMed ID: 27373549
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Screening of synthetic PDE-5 inhibitors and their analogues as adulterants: analytical techniques and challenges.
    Patel DN; Li L; Kee CL; Ge X; Low MY; Koh HL
    J Pharm Biomed Anal; 2014 Jan; 87():176-90. PubMed ID: 23721687
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Combined secondary electrospray and corona discharge ionization (SECDI) for improved detection of explosive vapors using drift tube ion mobility spectrometry.
    Mullen M; Giordano BC
    Talanta; 2020 Mar; 209():120544. PubMed ID: 31892090
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of drugs of abuse in bovine dentin using liquid chromatography-electrospray ionization tandem mass spectrometry.
    Spinner J; Klima M; Kempf J; Huppertz LM; Auwärter V; Altenburger MJ; Neukamm MA
    J Mass Spectrom; 2014 Dec; 49(12):1306-13. PubMed ID: 25476949
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Forced degradation and impurity profiling: recent trends in analytical perspectives.
    Jain D; Basniwal PK
    J Pharm Biomed Anal; 2013 Dec; 86():11-35. PubMed ID: 23969330
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of 17 illicit drugs in oral fluid using isotope dilution ultra-high performance liquid chromatography/tandem mass spectrometry with three atmospheric pressure ionizations.
    Wang IT; Feng YT; Chen CY
    J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Nov; 878(30):3095-105. PubMed ID: 20951654
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rapid screening of abused drugs by direct analysis in real time (DART) coupled to time-of-flight mass spectrometry (TOF-MS) combined with ion mobility spectrometry (IMS).
    Lian R; Wu Z; Lv X; Rao Y; Li H; Li J; Wang R; Ni C; Zhang Y
    Forensic Sci Int; 2017 Oct; 279():268-280. PubMed ID: 28888687
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantification of drugs of abuse and some stimulants in hair samples by liquid chromatography-electrospray ionization ion trap mass spectrometry.
    Bucelli F; Fratini A; Bavazzano P; Comodo N
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Dec; 877(31):3931-6. PubMed ID: 19864191
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry.
    Gunnar T; Ariniemi K; Lillsunde P
    J Mass Spectrom; 2005 Jun; 40(6):739-53. PubMed ID: 15806585
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Separation of isomeric peptides using electrospray ionization/high-resolution ion mobility spectrometry.
    Wu C; Siems WF; Klasmeier J; Hill HH
    Anal Chem; 2000 Jan; 72(2):391-5. PubMed ID: 10658335
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of human breath samples using a modified thermal desorption: gas chromatography electrospray ionization interface.
    Reynolds JC; Jimoh MA; Guallar-Hoyas C; Creaser CS; Siddiqui S; Paul Thomas CL
    J Breath Res; 2014 Sep; 8(3):037105. PubMed ID: 25190194
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.